Reliability of pressure measurements: the EM ED F system.

J Hughes1, L Pratt, K Linge, P Clark, L Klenerman.   

Abstract

The reliability of foot pressure measurement using the EMED F system has been tested by recording 25 walks with 10 volunteer subjects at three different speeds. Coefficients of reliability calculated for 1-25 walks showed that a good level of reliability was achieved using one measurement for most force/pressure variables but when the mean result of three or more walks was used reliability was excellent. Measurements related to time were more variable than the total force, the peak pressure and the area. The total force and peak pressure were also shown to increase with increasing speed but this was not true for all sites on the foot.
Copyright © 1991. Published by Elsevier Ltd.

Year:  1991        PMID: 23916339     DOI: 10.1016/0268-0033(91)90036-P

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  19 in total

1.  Pedobarographic analysis following Ponseti treatment for congenital clubfoot.

Authors:  Marc F Sinclair; Kerstin Bosch; Dieter Rosenbaum; Stephanie Böhm
Journal:  Clin Orthop Relat Res       Date:  2009-02-28       Impact factor: 4.176

2.  Spatio-temporal alignment of pedobarographic image sequences.

Authors:  Francisco P M Oliveira; Andreia Sousa; Rubim Santos; João Manuel R S Tavares
Journal:  Med Biol Eng Comput       Date:  2011-04-08       Impact factor: 2.602

3.  Comparison of shoe insole materials by neural network analysis.

Authors:  J G Barton; A Lees
Journal:  Med Biol Eng Comput       Date:  1996-11       Impact factor: 2.602

4.  Enhanced spatio-temporal alignment of plantar pressure image sequences using B-splines.

Authors:  Francisco P M Oliveira; João Manuel R S Tavares
Journal:  Med Biol Eng Comput       Date:  2012-11-08       Impact factor: 2.602

5.  The reliability of plantar pressure assessment during barefoot level walking in children aged 7-11 years.

Authors:  Stephen D Cousins; Stewart C Morrison; Wendy I Drechsler
Journal:  J Foot Ankle Res       Date:  2012-03-20       Impact factor: 2.303

6.  MEDIAL FOOT LOADING ON ANKLE AND KNEE BIOMECHANICS.

Authors:  Lyneil C J Mitchell; Kevin R Ford; Stephen Minning; Gregory D Myer; Robert E Mangine; Timothy E Hewett
Journal:  N Am J Sports Phys Ther       Date:  2008-08-01

7.  Reliability of the TekScan MatScan(R) system for the measurement of plantar forces and pressures during barefoot level walking in healthy adults.

Authors:  Gerard V Zammit; Hylton B Menz; Shannon E Munteanu
Journal:  J Foot Ankle Res       Date:  2010-06-18       Impact factor: 2.303

8.  Reliability of plantar pressure platforms.

Authors:  Jocelyn F Hafer; Mark W Lenhoff; Jinsup Song; Joanne M Jordan; Marian T Hannan; Howard J Hillstrom
Journal:  Gait Posture       Date:  2013-02-28       Impact factor: 2.840

9.  Dynamic Adduction Angle of Forefoot Measured With a Novel Technique And Its Relationship With Functional Outcomes.

Authors:  Nirav Hasmukh Amin; Andre Jakoi; Volpi Ms Alexander; Martin Joseph Morrison; Per Trobisch
Journal:  Malays J Med Sci       Date:  2016-03

10.  Plantar foot pressures after the augmented low dye taping technique.

Authors:  Bill Vicenzino; Thomas McPoil; Susan Buckland
Journal:  J Athl Train       Date:  2007 Jul-Sep       Impact factor: 2.860

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.