Gerard V Zammit1, Hylton B Menz, Shannon E Munteanu. 1. Musculoskeletal Research Centre, Faculty of Health Sciences, La Trobe University, Victoria 3086, Australia. g.zammit@latrobe.edu.au.
Abstract
BACKGROUND: Plantar pressure systems are increasingly being used to evaluate foot function in both research settings and in clinical practice. The purpose of this study was to investigate the reliability of the TekScan MatScan(R) system in assessing plantar forces and pressures during barefoot level walking. METHODS: Thirty participants were assessed for the reliability of measurements taken one week apart for the variables maximum force, peak pressure and average pressure. The following seven regions of the foot were investigated; heel, midfoot, 3rd-5th metatarsophalangeal joint, 2nd metatarsophalangeal joint, 1st metatarsophalangeal joint, hallux and the lesser toes. RESULTS: Reliability was assessed using both the mean and the median values of three repeated trials. The system displayed moderate to good reliability of mean and median calculations for the three analysed variables across all seven regions, as indicated by intra-class correlation coefficients ranging from 0.44 to 0.95 for the mean and 0.54 to 0.97 for the median, and coefficients of variation ranging from 5 to 20% for the mean and 3 to 23% for the median. Selecting the median value of three repeated trials yielded slightly more reliable results than the mean. CONCLUSIONS: These findings indicate that the TekScan MatScan(R) system demonstrates generally moderate to good reliability.
BACKGROUND: Plantar pressure systems are increasingly being used to evaluate foot function in both research settings and in clinical practice. The purpose of this study was to investigate the reliability of the TekScan MatScan(R) system in assessing plantar forces and pressures during barefoot level walking. METHODS: Thirty participants were assessed for the reliability of measurements taken one week apart for the variables maximum force, peak pressure and average pressure. The following seven regions of the foot were investigated; heel, midfoot, 3rd-5th metatarsophalangeal joint, 2nd metatarsophalangeal joint, 1st metatarsophalangeal joint, hallux and the lesser toes. RESULTS: Reliability was assessed using both the mean and the median values of three repeated trials. The system displayed moderate to good reliability of mean and median calculations for the three analysed variables across all seven regions, as indicated by intra-class correlation coefficients ranging from 0.44 to 0.95 for the mean and 0.54 to 0.97 for the median, and coefficients of variation ranging from 5 to 20% for the mean and 3 to 23% for the median. Selecting the median value of three repeated trials yielded slightly more reliable results than the mean. CONCLUSIONS: These findings indicate that the TekScan MatScan(R) system demonstrates generally moderate to good reliability.
Authors: Sicco A Bus; Robert W M van Deursen; Rajani V Kanade; Marieke Wissink; Erik A Manning; Jeff G van Baal; Keith G Harding Journal: Gait Posture Date: 2009-02-13 Impact factor: 2.840
Authors: Shannon E Munteanu; Hylton B Menz; Gerard V Zammit; Karl B Landorf; Christopher J Handley; Ayman Elzarka; Jason Deluca Journal: J Foot Ankle Res Date: 2009-01-16 Impact factor: 2.303
Authors: Yvonne M Golightly; Alyssa B Dufour; Marian T Hannan; Howard J Hillstrom; Patricia P Katz; Joanne M Jordan Journal: J Gerontol A Biol Sci Med Sci Date: 2015-08-21 Impact factor: 6.053
Authors: Alyssa B Dufour; Elena Losina; Hylton B Menz; Michael P LaValley; Marian T Hannan Journal: Obes Res Clin Pract Date: 2016-11-22 Impact factor: 2.288
Authors: Hylton B Menz; Alyssa B Dufour; Jody L Riskowski; Howard J Hillstrom; Marian T Hannan Journal: Rheumatology (Oxford) Date: 2013-09-17 Impact factor: 7.580
Authors: Jocelyn F Hafer; Mark W Lenhoff; Jinsup Song; Joanne M Jordan; Marian T Hannan; Howard J Hillstrom Journal: Gait Posture Date: 2013-02-28 Impact factor: 2.840
Authors: Alyssa B Dufour; Virginia A Casey; Yvonne M Golightly; Marian T Hannan Journal: Arthritis Care Res (Hoboken) Date: 2014-12 Impact factor: 4.794
Authors: Hylton B Menz; Alyssa B Dufour; Jody L Riskowski; Howard J Hillstrom; Marian T Hannan Journal: Arthritis Care Res (Hoboken) Date: 2013-12 Impact factor: 4.794
Authors: Yvonne M Golightly; Marian T Hannan; Alyssa B Dufour; Howard J Hillstrom; Joanne M Jordan Journal: Foot Ankle Int Date: 2014-07-18 Impact factor: 2.827