Savita Jadhav1, Tushar Sahasrabudhe, Vipul Kalley, Nageswari Gandham. 1. Associate Professor, Department of Microbiology, Pad. Dr. D.Y. Patil Medical College, Hospital & Research Centre (D.Y. Patil Vidyapeeth Pune) Pimpri-18. Maharashtra, India .
Abstract
INTRODUCTION: Approximately 10-40% of all the nosocomial infections are pulmonary, which lead to grave complications. Elderly, debilitated, or critically ill patients are at a high risk. The respiratory care equipments which include ventilators, humidifiers, nebulizers may have been identified as the potential vehicles which cause major nosocomial infections if they are colonized by fungi or bacteria. AIM: To determine the rate of colonization by bacteria and fungi of the oxygen humidifier chambers of the portable cylinders and central lines at our hospital. The Hudson's chambers of nebulizers were also studied for the same. METHODS: Swab samples were obtained from the equipments by using sterile cotton swabs on a tuesday, as these chambers were usually cleaned on every Saturday. Spot samples were taken from the ICUs, wards, the casualty and OPDs on a single day. Air samples were also obtained on the same day to determine whether the fungal spore load in the inhaled room air was normal or high. We performed a disinfection with 70% ethanol after cleaning these devices. RESULTS: 53/70 (75.71%) samples showed fungal growth; out of which, 23/33 (69.70%) were from the ICU, 24/30(80%) were from the wards and 6/7 (85.71%) were from the OPDs. 23/30 (76.66%) swabs from the central line humidifiers, 18/23(78.26%) swabs from the O2 cylinder humidifiers and 8/17 (47.5%) swabs from the nebulizers grew bacteria. Of the total 61(87.14%) bacterial isolates, 42(68.85%) were gram negative bacteria and 19(31.14%) were gram positive cocci. Out of the 42 gram negative bacteria, 17 were multi-drug resistant like ESBL producers ie. Pseudomonas spp. (6) Acinetobacter spp.(4), Klebseilla pneumoniae (4), E.coli (2) and Stenotrophomonas maltophila (1). Our findings (before disinfection) showed that the colonization rate for fungi was 75% and that for bacteria, it was 87%. After the 70% ethanol disinfection and strict compliance with the hand hygiene, the colonization rates reduced significantly. The fungal colonization rate was reduced and only 15% fungi grew after the disinfection, while only 12% bacterial colonization rate was found. CONCLUSION: This study indicates a potential in-hospital source of allergens and infections. The oxygen and nebulizer chambers need to be cleaned more frequently with disinfectants, to control the possible nosocomial infections.
INTRODUCTION: Approximately 10-40% of all the nosocomial infections are pulmonary, which lead to grave complications. Elderly, debilitated, or critically illpatients are at a high risk. The respiratory care equipments which include ventilators, humidifiers, nebulizers may have been identified as the potential vehicles which cause major nosocomial infections if they are colonized by fungi or bacteria. AIM: To determine the rate of colonization by bacteria and fungi of the oxygen humidifier chambers of the portable cylinders and central lines at our hospital. The Hudson's chambers of nebulizers were also studied for the same. METHODS: Swab samples were obtained from the equipments by using sterile cotton swabs on a tuesday, as these chambers were usually cleaned on every Saturday. Spot samples were taken from the ICUs, wards, the casualty and OPDs on a single day. Air samples were also obtained on the same day to determine whether the fungal spore load in the inhaled room air was normal or high. We performed a disinfection with 70% ethanol after cleaning these devices. RESULTS: 53/70 (75.71%) samples showed fungal growth; out of which, 23/33 (69.70%) were from the ICU, 24/30(80%) were from the wards and 6/7 (85.71%) were from the OPDs. 23/30 (76.66%) swabs from the central line humidifiers, 18/23(78.26%) swabs from the O2 cylinder humidifiers and 8/17 (47.5%) swabs from the nebulizers grew bacteria. Of the total 61(87.14%) bacterial isolates, 42(68.85%) were gram negative bacteria and 19(31.14%) were gram positive cocci. Out of the 42 gram negative bacteria, 17 were multi-drug resistant like ESBL producers ie. Pseudomonas spp. (6) Acinetobacter spp.(4), Klebseilla pneumoniae (4), E.coli (2) and Stenotrophomonas maltophila (1). Our findings (before disinfection) showed that the colonization rate for fungi was 75% and that for bacteria, it was 87%. After the 70% ethanol disinfection and strict compliance with the hand hygiene, the colonization rates reduced significantly. The fungal colonization rate was reduced and only 15% fungi grew after the disinfection, while only 12% bacterial colonization rate was found. CONCLUSION: This study indicates a potential in-hospital source of allergens and infections. The oxygen and nebulizer chambers need to be cleaned more frequently with disinfectants, to control the possible nosocomial infections.
Authors: K F Anderson; D R Lonsway; J K Rasheed; J Biddle; B Jensen; L K McDougal; R B Carey; A Thompson; S Stocker; B Limbago; J B Patel Journal: J Clin Microbiol Date: 2007-06-20 Impact factor: 5.948
Authors: Jane Bell; Lauren Alexander; Jane Carson; Amanda Crossan; John McCaughan; Hazel Mills; Damian O'Neill; John E Moore; B Cherie Millar Journal: Breathe (Sheff) Date: 2020-06
Authors: Eric Woods; Gabriel Cohen; Eric Bressman; David Lin; Nathalie E Zeitouni; Colleen Beckford; Camille Hamula; Harm van Bakel; Mitchell Sullivan; Deena R Altman; Daniel Caplivski Journal: Case Rep Infect Dis Date: 2017-12-28