Literature DB >> 23904894

Complications and associated risk factors at screw removal in slipped capital femoral epiphysis treated by cannulated stainless steel screws.

Juan Pretell-Mazzini1, Victor Rodriguez-Vega, Jorge Muñoz-Ledesma, Eva María Andrés-Esteban, Rafael Marti-Ciruelos, José Luis González-López, Angel Curto-De la Mano.   

Abstract

PURPOSE: The aim of our study is to report our complication rate and analyze the associated risk factors when removing cannulated stainless steel screws for SCFE fixation.
METHODS: This was a multicenter retrospective study of patients who underwent removal of cannulated stainless steel screws after a mean time of 2.03 years of implantation. Thirty-two patients were included (38 hips) with a mean of 13.7 years of age during screw removal surgery. The mean post-removal follow up time was 1.6 years. In all cases the removal of screws was done systematically. Demographic data, possible risk factors related to removal failure, as well as post-removal complications such as post-removal fractures, infections and scar issues were recorded.
RESULTS: A removal failure rate of 15.79 % (6/38) was found. The removal surgical time was longer than the initial fixation time but without statistical significance (70.78 vs 61.84 m, p = 0.196). However, the duration of screw implantation (r (2): 7.09; IC: 1.12-13.06) and screw head bony coverage (r (2): 21.32; IC: 5.58-37.06) were both related to this prolonged time. Multivariant analysis revealed that a fully threaded cannulated screw had the lowest removal failure risk (OR: 0.3; IC: 0.14-0.61). There were no postremoval complications recorded.
CONCLUSIONS: We recommend to use full threaded cannulated stainless steel screws and to perform the procedure as soon as the physis are closed to decrease the surgical time. It is a safe procedure based on a low rate of complications such as post-removal fractures, infection and scar issues.

Entities:  

Keywords:  Full threaded screws; Removal failure rate; Slipped capital femoral epiphysis; Stainless steel screws; Titanium screws

Year:  2012        PMID: 23904894      PMCID: PMC3425694          DOI: 10.1007/s11832-012-0425-z

Source DB:  PubMed          Journal:  J Child Orthop        ISSN: 1863-2521            Impact factor:   1.548


  16 in total

1.  Failures of pin removal after in situ pinning of slipped capital femoral epiphyses: a comparison of different pin types.

Authors:  E J Vresilovic; K P Spindler; W W Robertson; R S Davidson; D S Drummond
Journal:  J Pediatr Orthop       Date:  1990 Nov-Dec       Impact factor: 2.324

2.  Demographic predictors of severity of stable slipped capital femoral epiphyses.

Authors:  Randall T Loder; Trevor Starnes; Greg Dikos; David D Aronsson
Journal:  J Bone Joint Surg Am       Date:  2006-01       Impact factor: 5.284

3.  Complications at screw removal in slipped capital femoral epiphysis treated by cannulated titanium screws.

Authors:  T Ilchmann; K Parsch
Journal:  Arch Orthop Trauma Surg       Date:  2006-05-23       Impact factor: 3.067

Review 4.  Evidence-based analysis of removal of orthopaedic implants in the pediatric population.

Authors:  Ellen M Raney; David M Freccero; Lori A Dolan; Donald E Lighter; Ramona R Fillman; Henry G Chambers
Journal:  J Pediatr Orthop       Date:  2008 Oct-Nov       Impact factor: 2.324

5.  Pin removal in slipped capital femoral epiphysis: the unsuitability of titanium devices.

Authors:  T K Lee; R J Haynes; J A Longo; J R Chu
Journal:  J Pediatr Orthop       Date:  1996 Jan-Feb       Impact factor: 2.324

6.  Does corrosion matter?

Authors:  J Black
Journal:  J Bone Joint Surg Br       Date:  1988-08

7.  Removal of orthopedic implants in children: morbidity and postoperative radiologic changes.

Authors:  M E Lovell; C S Galasko; N B Wright
Journal:  J Pediatr Orthop B       Date:  1999-04       Impact factor: 1.041

8.  Internal fixation of slipped femoral capital epiphyses.

Authors:  H U Cameron; M Wang; J Koreska
Journal:  Clin Orthop Relat Res       Date:  1978 Nov-Dec       Impact factor: 4.176

9.  Metal removal in a pediatric population: benign procedure or necessary evil?

Authors:  T P Schmalzried; T J Grogan; P A Neumeier; F J Dorey
Journal:  J Pediatr Orthop       Date:  1991 Jan-Feb       Impact factor: 2.324

Review 10.  Slipped capital femoral epiphysis.

Authors:  Randall T Loder; David D Aronsson; Stuart L Weinstein; Gert J Breur; Reinhold Ganz; Michael Leunig
Journal:  Instr Course Lect       Date:  2008
View more
  2 in total

Review 1.  [Compatibility and allergies of osteosynthesis materials].

Authors:  M Thomsen; P Thomas
Journal:  Unfallchirurg       Date:  2017-02       Impact factor: 1.000

Review 2.  Role of the prophylactic fixation of contralateral unaffected hip in paediatric unilateral slipped capital femoral epiphysis: a systematic review.

Authors:  Filippo Maria Anghilieri; Ilaria Morelli; Giuseppe M Peretti; Fabio Verdoni; Domenico Curci
Journal:  EFORT Open Rev       Date:  2022-02-16
  2 in total