Prosthesis failure within 2 years of implantation is highly predictive of infection.

María Eugenia Portillo1, Margarita Salvadó, Albert Alier, Lluisa Sorli, Santos Martínez, Juan Pablo Horcajada, Lluis Puig.   

Abstract

BACKGROUND: The outcome of revision surgery depends on accurate determination of the cause of prosthesis failure because treatment differs profoundly among aseptic loosening, mechanical failure, and prosthetic joint infections (PJI). QUESTIONS/PURPOSES: We sought to determine (1) the predictive role of the interval from primary to revision surgery in determining the reason for prosthesis failure of a hip, knee, shoulder, or elbow arthroplasty, and (2) whether positive cultures during revision surgery for aseptic loosening were associated with shorter event-free survival of the prosthesis.
METHODS: All patients undergoing revision surgery between July 2010 and January 2012 were included in a prospective cohort of 112 patients, and were classified as having had failure from aseptic loosening (56%), mechanical failure (15%), or PJI (29%). To make the diagnosis of PJI, at surgery we used a standardized enhanced diagnostic approach in all patients including sampling of five periprosthetic tissue specimens, sonication of removed prosthetic components, prolonged incubation of aerobic and anaerobic cultures, and multiplex PCR of sonication fluid in aseptic loosening cases. Kaplan-Meier survival and Cox proportional hazards regression analysis were performed.
RESULTS: The median time from primary to revision surgery was (p < 0.001) longer for patients with aseptic loosening (7.8 years) than for patients with mechanical failure (1.6 years) or PJI (2 years). No difference in the time to revision was observed for patients with aseptic loosening with positive or negative microbiological cultures (p = 0.594). Propionibacterium acnes was cultured below the established microbiological criteria for positivity in 12 (19%) procedures that had been presumed to have been revisions for aseptic loosening.
CONCLUSIONS: PJI should be considered in all revisions performed within 2 years of implantation even in the absence of clinical or laboratory findings suggestive for infection. However, the growth of low-virulence microorganisms below the cut-off in revisions for apparent aseptic loosening is not associated with early prosthesis failure.

Entities:  

Mesh:

Year:  2013        PMID: 23904245      PMCID: PMC3792275          DOI: 10.1007/s11999-013-3200-7

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  32 in total

1.  The Swedish Total Hip Replacement Register.

Authors:  Henrik Malchau; Peter Herberts; Thomas Eisler; Göran Garellick; Peter Söderman
Journal:  J Bone Joint Surg Am       Date:  2002       Impact factor: 5.284

2.  The Norwegian Arthroplasty Register: 11 years and 73,000 arthroplasties.

Authors:  L I Havelin; L B Engesaeter; B Espehaug; O Furnes; S A Lie; S E Vollset
Journal:  Acta Orthop Scand       Date:  2000-08

Review 3.  Prosthetic-joint infections.

Authors:  Werner Zimmerli; Andrej Trampuz; Peter E Ochsner
Journal:  N Engl J Med       Date:  2004-10-14       Impact factor: 91.245

4.  Low sensitivity of histology to predict the presence of microorganisms in suspected aseptic loosening of a joint prosthesis.

Authors:  Guillem Bori; Alex Soriano; Sebastián García; Xavier Gallart; Luis Casanova; Carme Mallofre; Manel Almela; José A Martínez; Josep Riba; Josep Mensa
Journal:  Mod Pathol       Date:  2006-06       Impact factor: 7.842

Review 5.  Prosthetic joint infections: update in diagnosis and treatment.

Authors:  Andrej Trampuz; Werner Zimmerli
Journal:  Swiss Med Wkly       Date:  2005-04-30       Impact factor: 2.193

Review 6.  Epidemiology and new developments in the diagnosis of prosthetic joint infection.

Authors:  Stéphane Corvec; María E Portillo; Bruna Maria Pasticci; Olivier Borens; Andrej Trampuz
Journal:  Int J Artif Organs       Date:  2012-10       Impact factor: 1.595

Review 7.  Is aseptic loosening truly aseptic?

Authors:  Carl L Nelson; Alex C McLaren; Sandra G McLaren; Jeffrey W Johnson; Mark S Smeltzer
Journal:  Clin Orthop Relat Res       Date:  2005-08       Impact factor: 4.176

8.  Is "aseptic" loosening of the prosthetic cup after total hip replacement due to nonculturable bacterial pathogens in patients with low-grade infection?

Authors:  A Ince; J Rupp; L Frommelt; A Katzer; J Gille; J F Löhr
Journal:  Clin Infect Dis       Date:  2004-11-02       Impact factor: 9.079

9.  Synovial fluid leukocyte count and differential for the diagnosis of prosthetic knee infection.

Authors:  Andrej Trampuz; Arlen D Hanssen; Douglas R Osmon; Jayawant Mandrekar; James M Steckelberg; Robin Patel
Journal:  Am J Med       Date:  2004-10-15       Impact factor: 4.965

Review 10.  The problem is osteolysis.

Authors:  W H Harris
Journal:  Clin Orthop Relat Res       Date:  1995-02       Impact factor: 4.176

View more
  28 in total

Review 1.  [Orthopaedic implant-associated infections: Update of antimicrobial therapy].

Authors:  W Zimmerli
Journal:  Orthopade       Date:  2015-12       Impact factor: 1.087

2.  Does Preoperative Antimicrobial Prophylaxis Influence the Diagnostic Potential of Periprosthetic Tissues in Hip or Knee Infections?

Authors:  Klemen Bedenčič; Martina Kavčič; Nataša Faganeli; Rene Mihalič; Blaž Mavčič; Jožica Dolenc; Zlatka Bajc; Rihard Trebše
Journal:  Clin Orthop Relat Res       Date:  2015-08-08       Impact factor: 4.176

3.  Improved diagnosis of orthopedic implant-associated infection by inoculation of sonication fluid into blood culture bottles.

Authors:  María Eugenia Portillo; Margarita Salvadó; Andrej Trampuz; Ana Siverio; Albert Alier; Lluisa Sorli; Santos Martínez; Daniel Pérez-Prieto; Juan P Horcajada; Lluis Puig-Verdie
Journal:  J Clin Microbiol       Date:  2015-03-04       Impact factor: 5.948

4.  C-reactive protein misdiagnoses delayed postoperative spinal implant infections in patients with low-virulent microorganisms.

Authors:  Doruk Akgün; Justus Bürger; Matthias Pumberger; Michael Putzier
Journal:  Eur Spine J       Date:  2019-02-02       Impact factor: 3.134

5.  CORR Insights®: the Otto Aufranc Award: modifiable versus nonmodifiable risk factors for infection after hip arthroplasty.

Authors:  Lucian Bogdan Solomon
Journal:  Clin Orthop Relat Res       Date:  2014-08-13       Impact factor: 4.176

Review 6.  Ten questions on prosthetic shoulder infection.

Authors:  Elizabeth M Pinder; Joshua Cy Ong; R Stephen Bale; Ian A Trail
Journal:  Shoulder Elbow       Date:  2016-03-08

7.  [Periprosthetic infection after hip arthroplasty].

Authors:  T Winkler; A Trampuz; S Hardt; V Janz; C Kleber; C Perka
Journal:  Orthopade       Date:  2014-01       Impact factor: 1.087

8.  Integrated IT Platform for Coordination of Diagnosis, Treatment, and Aftercare of Prosthetic Joint Infections.

Authors:  Rüdiger VON Eisenhart-Rothe; Heinrich Maria Laurentius Mühlhofer; Christian Suren; Susanne Feihl; Christiane Querbach; Patrick Rämer; Florian Pohlig; Jakob Thurner; Rudolf Bernard; Dirk Busch
Journal:  In Vivo       Date:  2019 Sep-Oct       Impact factor: 2.155

Review 9.  Management of painful reverse shoulder arthroplasty.

Authors:  Anders L Ekelund
Journal:  Shoulder Elbow       Date:  2017-04-09

Review 10.  Implantable Device-Related Infection.

Authors:  J Scott VanEpps; John G Younger
Journal:  Shock       Date:  2016-12       Impact factor: 3.454

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.