Automatic selection of tube potential for radiation dose reduction in vascular and contrast-enhanced abdominopelvic CT.

Lifeng Yu1, Joel G Fletcher, Katharine L Grant, Rickey E Carter, David M Hough, John M Barlow, Terri J Vrtiska, Eric E Williamson, Phillip M Young, Brian C Goss, Maria Shiung, Shuai Leng, Ranier Raupach, Bernhard Schmidt, Thomas Flohr, Cynthia H McCollough.   

Abstract

OBJECTIVE: The purpose of this study is to assess the ability of a novel automatic tube potential selection tool to reduce radiation dose while maintaining diagnostic quality in CT angiography (CTA) and contrast-enhanced abdominopelvic CT.
MATERIALS AND METHODS: One hundred one CTA examinations and 90 contrastenhanced abdominopelvic examinations were performed using an automatic tube potential selection tool on a 128-MDCT scanner. Two vascular radiologists and two abdominal radiologists evaluated the image quality for sharpness, noise, artifact, and diagnostic confidence. In a subset of patients who had undergone prior studies (CTA, 28 patients; abdominopelvic CT, 25 patients), a side-by-side comparison was performed by a separate radiologist. Dose reduction and iodine contrast-to-noise ratio resulting from use of the tool were calculated.
RESULTS: For CTA, 80 or 100 kV was selected for 73% of the scans, with a mean dose reduction of 36% relative to the reference 120-kV protocol. For abdominopelvic CT examinations, 80 or 100 kV was used for 55% of the scans, with a mean dose reduction of 25%. Overall dose reduction relative to the reference 120-kV protocol was 25% and 13% for CTA and abdominopelvic CT scans, respectively. Over 98% of scans had acceptable sharpness, noise texture, artifact, and diagnostic confidence for both readers and diagnostic tasks; 94-100% of scans had acceptable noise. Iodine contrast-to-noise ratio was significantly higher than (p < 0.001) or similar to (p = 0.11) that of prior scans, and equivalent quality was achieved despite the dose reduction.
CONCLUSION: Automatic tube potential selection provides an efficient and quantitativeway to guide the selection of the optimal tube potential for CTA and abdominopelvic CT examinations.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23883244     DOI: 10.2214/AJR.12.9610

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  14 in total

1.  Aortic CT angiography dose reduction: investigation of optimal noise index and iterative algorithm strength in combination with low kV.

Authors:  Osvaldo Rampado; Stefania Busso; Domenica Garabello; Ezio Marengo; Marco Valerio; Simona Capello; Simona Veglia; Ottavio Davini; Roberto Ropolo
Journal:  Radiol Med       Date:  2015-12-16       Impact factor: 3.469

2.  Observer performance for adaptive, image-based denoising and filtered back projection compared to scanner-based iterative reconstruction for lower dose CT enterography.

Authors:  Joel G Fletcher; Amy K Hara; Jeff L Fidler; Alvin C Silva; John M Barlow; Rickey E Carter; Adam Bartley; Maria Shiung; David R Holmes; Nicolas K Weber; David H Bruining; Lifeng Yu; Cynthia H McCollough
Journal:  Abdom Imaging       Date:  2015-06

3.  Symptomatic and Radiographic Manifestations of Kidney Stone Recurrence and Their Prediction by Risk Factors: A Prospective Cohort Study.

Authors:  Matthew R D'Costa; William E Haley; Kristin C Mara; Felicity T Enders; Terri J Vrtiska; Vernon M Pais; Steven J Jacobsen; Cynthia H McCollough; John C Lieske; Andrew D Rule
Journal:  J Am Soc Nephrol       Date:  2019-06-07       Impact factor: 10.121

4.  Image quality and radiation reduction of 320-row area detector CT coronary angiography with optimal tube voltage selection and an automatic exposure control system: comparison with body mass index-adapted protocol.

Authors:  Jiyeon Lim; Eun-Ah Park; Whal Lee; Hackjoon Shim; Jin Wook Chung
Journal:  Int J Cardiovasc Imaging       Date:  2015-01-22       Impact factor: 2.357

5.  Image quality and radiation dose of brain computed tomography in children: effects of decreasing tube voltage from 120 kVp to 80 kVp.

Authors:  Ji Eun Park; Young Hun Choi; Jung-Eun Cheon; Woo Sun Kim; In-One Kim; Hyun Suk Cho; Young Jin Ryu; Yu Jin Kim
Journal:  Pediatr Radiol       Date:  2017-03-14

6.  Imaging the Parasinus Region with a Third-Generation Dual-Source CT and the Effect of Tin Filtration on Image Quality and Radiation Dose.

Authors:  M M Lell; M S May; M Brand; A Eller; T Buder; E Hofmann; M Uder; W Wuest
Journal:  AJNR Am J Neuroradiol       Date:  2015-03-26       Impact factor: 3.825

7.  Should radiologists care about kV? Phantom and clinical study of effects of kV on hemoperitoneum HU in the setting of splenic injuries.

Authors:  Dillon Hickman; Jie Zhang; Kristen McQuerry; James Lee
Journal:  Emerg Radiol       Date:  2019-11-26

8.  Maximizing Iodine Contrast-to-Noise Ratios in Abdominal CT Imaging through Use of Energy Domain Noise Reduction and Virtual Monoenergetic Dual-Energy CT.

Authors:  Shuai Leng; Lifeng Yu; Joel G Fletcher; Cynthia H McCollough
Journal:  Radiology       Date:  2015-04-10       Impact factor: 11.105

9.  Observer Performance in the Detection and Classification of Malignant Hepatic Nodules and Masses with CT Image-Space Denoising and Iterative Reconstruction.

Authors:  Joel G Fletcher; Lifeng Yu; Zhoubo Li; Armando Manduca; Daniel J Blezek; David M Hough; Sudhakar K Venkatesh; Gregory C Brickner; Joseph C Cernigliaro; Amy K Hara; Jeff L Fidler; David S Lake; Maria Shiung; David Lewis; Shuai Leng; Kurt E Augustine; Rickey E Carter; David R Holmes; Cynthia H McCollough
Journal:  Radiology       Date:  2015-05-26       Impact factor: 11.105

Review 10.  Spontaneous Coronary Artery Dissection: Current State of the Science: A Scientific Statement From the American Heart Association.

Authors:  Sharonne N Hayes; Esther S H Kim; Jacqueline Saw; David Adlam; Cynthia Arslanian-Engoren; Katherine E Economy; Santhi K Ganesh; Rajiv Gulati; Mark E Lindsay; Jennifer H Mieres; Sahar Naderi; Svati Shah; David E Thaler; Marysia S Tweet; Malissa J Wood
Journal:  Circulation       Date:  2018-02-22       Impact factor: 29.690