Literature DB >> 23880868

Biomechanical comparison of vertebral augmentation with silicone and PMMA cement and two filling grades.

Tobias L Schulte1, Alexander Keiler, Felix Riechelmann, Tobias Lange, Werner Schmoelz.   

Abstract

PURPOSE: Vertebral augmentation with PMMA is a widely applied treatment of vertebral osteoporotic compression fractures. Subsequent fractures are a common complication, possibly due to the relatively high stiffness of PMMA in comparison with bone. Silicone as an augmentation material has biomechanical properties closer to those of bone and might, therefore, be an alternative. The study aimed to investigate the biomechanical differences, especially stiffness, of vertebral bodies with two augmentation materials and two filling grades.
METHODS: Forty intact human osteoporotic vertebrae (T10-L5) were studied. Wedge fractures were produced in a standardized manner. For treatment, PMMA and silicone at two filling grades (16 and 35 % vertebral body fill) were assigned to four groups. Each specimen received 5,000 load cycles with a high load range of 20-65 % of fracture force, and stiffness was measured. Additional low-load stiffness measurements (100-500 N) were performed for intact and augmented vertebrae and after cyclic loading.
RESULTS: Low-load stiffness testing after cyclic loading normalized to intact vertebrae showed increased stiffness with 35 and 16 % PMMA (115 and 110 %) and reduced stiffness with 35 and 16 % silicone (87 and 82 %). After cyclic loading (high load range), the stiffness normalized to the untreated vertebrae was 361 and 304 % with 35 and 16 % PMMA, and 243 and 222 % with 35 and 16 % silicone augmentation. For both high and low load ranges, the augmentation material had a significant effect on the stiffness of the augmented vertebra, while the filling grade did not significantly affect stiffness.
CONCLUSIONS: This study for the first time directly compared the stiffness of silicone-augmented and PMMA-augmented vertebral bodies. Silicone may be a viable option in the treatment of osteoporotic fractures and it has the biomechanical potential to reduce the risk of secondary fractures.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23880868      PMCID: PMC3843779          DOI: 10.1007/s00586-013-2908-0

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  56 in total

1.  Risk factors predicting the new symptomatic vertebral compression fractures after percutaneous vertebroplasty or kyphoplasty.

Authors:  Young-Joon Rho; Woo Jin Choe; Young Il Chun
Journal:  Eur Spine J       Date:  2011-12-09       Impact factor: 3.134

2.  Vertebroplasty with high-viscosity polymethylmethacrylate cement facilitates vertebral body restoration in vitro.

Authors:  Matthias Rüger; Werner Schmoelz
Journal:  Spine (Phila Pa 1976)       Date:  2009-11-15       Impact factor: 3.468

3.  The fracture risk of adjacent vertebrae is increased by the changed loading direction after a wedge fracture.

Authors:  René Aquarius; Jasper Homminga; Nico Verdonschot; Esther Tanck
Journal:  Spine (Phila Pa 1976)       Date:  2011-03-15       Impact factor: 3.468

4.  Percutaneous vertebroplasty is not a risk factor for new osteoporotic compression fractures: results from VERTOS II.

Authors:  C A H Klazen; A Venmans; J de Vries; W J van Rooij; F H Jansen; M C Blonk; P N M Lohle; J R Juttmann; E Buskens; K J van Everdingen; A Muller; H Fransen; O E Elgersma; W P Th M Mali; H J J Verhaar
Journal:  AJNR Am J Neuroradiol       Date:  2010-07-22       Impact factor: 3.825

5.  The effectiveness and safety of vertebroplasty for osteoporotic vertebral compression fractures. A double blind, prospective, randomized, controlled study.

Authors:  Umile Giuseppe Longo; Mattia Loppini; Luca Denaro; Maria Luisa Brandi; Nicola Maffulli; Vincenzo Denaro
Journal:  Clin Cases Miner Bone Metab       Date:  2010-05

6.  Effect of vertebroplasty on pain relief, quality of life, and the incidence of new vertebral fractures: a 12-month randomized follow-up, controlled trial.

Authors:  Jordi Blasco; Angeles Martinez-Ferrer; Juan Macho; Luis San Roman; Jaume Pomés; Josep Carrasco; Ana Monegal; Nuria Guañabens; Pilar Peris
Journal:  J Bone Miner Res       Date:  2012-05       Impact factor: 6.741

7.  Analysis of adjacent fracture after percutaneous vertebroplasty: does intradiscal cement leakage really increase the risk of adjacent vertebral fracture?

Authors:  Kyung-Ah Lee; Suk-Joo Hong; Seunghun Lee; In Ho Cha; Baek-Hyun Kim; Eun-Young Kang
Journal:  Skeletal Radiol       Date:  2011-03-12       Impact factor: 2.199

8.  New vertebral osteoporotic compression fractures after percutaneous vertebroplasty: retrospective analysis of risk factors.

Authors:  Wei-Che Lin; Tien-Tsai Cheng; Yu-Chang Lee; Tsu-Nai Wang; Yu-Fan Cheng; Chun-Chung Lui; Chun-Yen Yu
Journal:  J Vasc Interv Radiol       Date:  2008-02       Impact factor: 3.464

9.  Predictive factors for subsequent vertebral fracture after percutaneous vertebroplasty.

Authors:  Yong Ahn; June Ho Lee; Ho-Yeon Lee; Sang-Ho Lee; Sang-Hyun Keem
Journal:  J Neurosurg Spine       Date:  2008-08

10.  The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit: finite-element analysis.

Authors:  Anne Polikeit; Lutz Peter Nolte; Stephen J Ferguson
Journal:  Spine (Phila Pa 1976)       Date:  2003-05-15       Impact factor: 3.468

View more
  6 in total

1.  Biomechanical evaluation of an injectable and biodegradable copolymer P(PF-co-CL) in a cadaveric vertebral body defect model.

Authors:  Zhong Fang; Hugo Giambini; Heng Zeng; Jon J Camp; Mahrokh Dadsetan; Richard A Robb; Kai-Nan An; Michael J Yaszemski; Lichun Lu
Journal:  Tissue Eng Part A       Date:  2014-01-10       Impact factor: 3.845

2.  Timing of PMMA cement application for pedicle screw augmentation affects screw anchorage.

Authors:  Werner Schmoelz; Christian Heinz Heinrichs; Sven Schmidt; Angel R Piñera; Felix Tome-Bermejo; Javier M Duart; Marlies Bauer; Luis Álvarez Galovich
Journal:  Eur Spine J       Date:  2017-04-03       Impact factor: 3.134

3.  Modification of PMMA vertebroplasty cement for reduced stiffness by addition of normal saline: a material properties evaluation.

Authors:  Christian Schröder; Mai Nguyen; Michael Kraxenberger; Yan Chevalier; Carolin Melcher; Bernd Wegener; Christof Birkenmaier
Journal:  Eur Spine J       Date:  2016-12-09       Impact factor: 3.134

4.  Elastoplasty as a promising novel technique: Vertebral augmentation with an elastic silicone-based polymer.

Authors:  Alessandro Gasbarrini; Riccardo Ghermandi; Yunus Emre Akman; Marco Girolami; Stefano Boriani
Journal:  Acta Orthop Traumatol Turc       Date:  2017-02-13       Impact factor: 1.511

5.  Local osteo-enhancement of osteoporotic vertebra with a triphasic bone implant material increases strength-a biomechanical study.

Authors:  Matthias Trost; Werner Schmoelz; Doris Wimmer; Romed Hörmann; Sönke Frey; Tobias Ludger Schulte
Journal:  Arch Orthop Trauma Surg       Date:  2020-02-27       Impact factor: 3.067

6.  Comparison of targeted percutaneous vertebroplasty and traditional percutaneous vertebroplasty for the treatment of osteoporotic vertebral compression fractures in the elderly.

Authors:  Lingli Yuan; Jianzhong Bai; Chunhui Geng; Guansheng Han; Wendi Xu; Zhongchuan Zhang; Hong Luo; Xunbing Zhu
Journal:  J Orthop Surg Res       Date:  2020-08-26       Impact factor: 2.359

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.