Literature DB >> 23868070

Taking the perfect nuclear image: quality control, acquisition, and processing techniques for cardiac SPECT, PET, and hybrid imaging.

James A Case1, Timothy M Bateman.   

Abstract

Nuclear Cardiology for the past 40 years has distinguished itself in its ability to non-invasively assess regional myocardial blood flow and identify obstructive coronary disease. This has led to advances in managing the diagnosis, risk stratification, and prognostic assessment of cardiac patients. These advances have all been predicated on the collection of high quality nuclear image data. National and international professional societies have established guidelines for nuclear laboratories to maintain high quality nuclear cardiology services. In addition, laboratory accreditation has further advanced the goal of the establishing high quality standards for the provision of nuclear cardiology services. This article summarizes the principles of nuclear cardiology single photon emission computed tomography (SPECT) and positron emission tomography (PET) imaging and techniques for maintaining quality: from the calibration of imaging equipment to post processing techniques. It also will explore the quality considerations of newer technologies such as cadmium zinc telleride (CZT)-based SPECT systems and absolute blood flow measurement techniques using PET.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23868070     DOI: 10.1007/s12350-013-9760-9

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  41 in total

1.  The value and practice of attenuation correction for myocardial perfusion SPECT imaging: a joint position statement from the American Society of Nuclear Cardiology and the Society of Nuclear Medicine.

Authors:  Robert C Hendel; James R Corbett; S James Cullom; E Gordon DePuey; Ernest V Garcia; Timothy M Bateman
Journal:  J Nucl Cardiol       Date:  2002 Jan-Feb       Impact factor: 5.952

2.  Wide-beam reconstruction half-time SPECT improves diagnostic certainty and preserves normalcy and accuracy: a quantitative perfusion analysis.

Authors:  Regina S Druz; Lawrence M Phillips; Michelle Chugkowski; Loukas Boutis; Bruce Rutkin; Stanley Katz
Journal:  J Nucl Cardiol       Date:  2010-12-23       Impact factor: 5.952

3.  Left ventricular apical thinning as normal anatomy.

Authors:  Kevin M Johnson; Hilary E Johnson; David A Dowe
Journal:  J Comput Assist Tomogr       Date:  2009 May-Jun       Impact factor: 1.826

4.  A novel high-sensitivity rapid-acquisition single-photon cardiac imaging camera.

Authors:  Sanjiv S Gambhir; Daniel S Berman; Jack Ziffer; Michael Nagler; Martin Sandler; Jim Patton; Brian Hutton; Tali Sharir; Shlomo Ben Haim; Simona Ben Haim
Journal:  J Nucl Med       Date:  2009-04       Impact factor: 10.057

Review 5.  Cardiac dedicated ultrafast SPECT cameras: new designs and clinical implications.

Authors:  Ernest V Garcia; Tracy L Faber; Fabio P Esteves
Journal:  J Nucl Med       Date:  2011-01-13       Impact factor: 10.057

Review 6.  Clinical review of attenuation-corrected cardiac SPECT.

Authors:  J R Corbett; E P Ficaro
Journal:  J Nucl Cardiol       Date:  1999 Jan-Feb       Impact factor: 5.952

7.  Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact.

Authors:  E G DePuey; A Rozanski
Journal:  J Nucl Med       Date:  1995-06       Impact factor: 10.057

8.  Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: comparison with ECG-gated Tc-99m sestamibi SPECT.

Authors:  Timothy M Bateman; Gary V Heller; A Iain McGhie; John D Friedman; James A Case; Jan R Bryngelson; Ginger K Hertenstein; Kelly L Moutray; Kimberly Reid; S James Cullom
Journal:  J Nucl Cardiol       Date:  2006 Jan-Feb       Impact factor: 5.952

9.  Motion correction and myocardial perfusion SPECT using manufacturer provided software. Does it affect image interpretation?

Authors:  Teresa Massardo; Rodrigo Jaimovich; Ricardo Faure; Manuel Muñoz; Rita Alay; Héctor Gatica
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-11-14       Impact factor: 9.236

10.  Diagnostic accuracy of rubidium-82 myocardial perfusion imaging with hybrid positron emission tomography/computed tomography in the detection of coronary artery disease.

Authors:  Uchechukwu K Sampson; Sharmila Dorbala; Atul Limaye; Raymond Kwong; Marcelo F Di Carli
Journal:  J Am Coll Cardiol       Date:  2007-02-26       Impact factor: 24.094

View more
  5 in total

Review 1.  Relationship between Calcium Score and Myocardial Scintigraphy in the Diagnosis of Coronary Disease.

Authors:  Fabio Paiva Rossini Siqueira; Claudio Tinoco Mesquita; Alair Augusto Sarmet M Damas Dos Santos; Marcelo Souto Nacif
Journal:  Arq Bras Cardiol       Date:  2016-07-18       Impact factor: 2.000

2.  Accurate myocardial blood flow measurements: Quality from start to finish is key to success.

Authors:  James Case
Journal:  J Nucl Cardiol       Date:  2016-12-02       Impact factor: 5.952

3.  Status of cardiovascular PET radiation exposure and strategies for reduction: An Information Statement from the Cardiovascular PET Task Force.

Authors:  James A Case; Robert A deKemp; Piotr J Slomka; Mark F Smith; Gary V Heller; Manuel D Cerqueira
Journal:  J Nucl Cardiol       Date:  2017-05-16       Impact factor: 5.952

4.  Simulation Study of a Frame-Based Motion Correction Algorithm for Positron Emission Imaging.

Authors:  Héctor Espinós-Morató; David Cascales-Picó; Marina Vergara; Ángel Hernández-Martínez; José María Benlloch Baviera; María José Rodríguez-Álvarez
Journal:  Sensors (Basel)       Date:  2021-04-08       Impact factor: 3.576

Review 5.  Quality markers in cardiology: measures of outcomes and clinical practice--a perspective of the Spanish Society of Cardiology and of Thoracic and Cardiovascular Surgery.

Authors:  José-Luis López-Sendón; José Ramón González-Juanatey; Fausto Pinto; José Cuenca Castillo; Lina Badimón; Regina Dalmau; Esteban González Torrecilla; José Ramón López Mínguez; Alicia M Maceira; Domingo Pascual-Figal; José Luis Pomar Moya-Prats; Alessandro Sionis; José Luis Zamorano
Journal:  Eur Heart J       Date:  2015-10-21       Impact factor: 29.983

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.