Literature DB >> 21181520

Wide-beam reconstruction half-time SPECT improves diagnostic certainty and preserves normalcy and accuracy: a quantitative perfusion analysis.

Regina S Druz1, Lawrence M Phillips, Michelle Chugkowski, Loukas Boutis, Bruce Rutkin, Stanley Katz.   

Abstract

BACKGROUND: Filtered back-projection (FBP) has been a standard in SPECT imaging. Newer iterative reconstruction algorithms have been shown to improve image quality and shorten acquisition time by taking into account statistical nature of raw data and using resolution recovery (RR). Wide-beam reconstruction (WBR) is an iterative algorithm with RR and adaptive noise control. We prospectively investigated outcome of WBR half-time SPECT on diagnostic certainty, accuracy and normalcy by quantitative perfusion analysis in comparison to full-time FBP images.
METHODS: 434 patients underwent rest (201)Tl/stress (99m)Tc-sestamibi full-time (20 s/stop, FBP) followed by a half-time (10 s/stop, WBR) SPECT. 34 patients underwent an angiogram within 90 days of SPECT. Diagnostic certainty was based on summed stress scores (SSS, 5-point/17 segments): normal if SSS ≤ 1, equivocal if SSS = 2-3, and abnormal if SSS ≥ 4. Perfusion defects were normalized to a percent of total myocardium, and expressed as %LV = defect SSS/maximal SSS × 100% with maximal SSS of 28 for left anterior descending (LAD), and of 20 for right coronary (RCA) and left circumflex (LCX). Change in %LV (Δ%LV = %LV FBP - %LV WBR) was evaluated for diagnostically discordant versus concordant scans.
RESULTS: SSS and %LV demonstrated very good correlation. There were significantly fewer equivocal scans with WBR (38 vs 151 FBP, P < .0001). Most discordant scans were equivocal FBP SPECT becoming normal with WBR (123/151). Δ%LV(LAD) for discordant studies was greater for women (5.4% ± 4.2%, P < .001), while Δ%LV(RCA,LCX) (4.4% ± 5.1%, P < .001; 1.2% ± 5.0%, P = .04) were greater for men. Normalcy rate was 91.4% for FBP and WBR with more definitely normal WBR studies (84.5% vs 43.9% for FBP, P < .0001). There were no differences in sensitivity (FBP 84.2%, WBR 81.6%), specificity (FBP 54.6%, WBR 63.6%), and accuracy (FBP, WBR 77.6%).
CONCLUSION: Quantitative perfusion analysis suggests that adaptive noise control with WBR improves uniformity of myocardium comparing to FBP techniques, and results in improved diagnostic certainty while preserving normalcy and accuracy.

Entities:  

Mesh:

Year:  2010        PMID: 21181520     DOI: 10.1007/s12350-010-9304-5

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  12 in total

Review 1.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association.

Authors:  Manuel D Cerqueira; Neil J Weissman; Vasken Dilsizian; Alice K Jacobs; Sanjiv Kaul; Warren K Laskey; Dudley J Pennell; John A Rumberger; Thomas Ryan; Mario S Verani
Journal:  J Nucl Cardiol       Date:  2002 Mar-Apr       Impact factor: 5.952

2.  ACC/AHA 2002 guideline update for exercise testing: summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee to Update the 1997 Exercise Testing Guidelines).

Authors:  Raymond J Gibbons; Gary J Balady; J Timothy Bricker; Bernard R Chaitman; Gerald F Fletcher; Victor F Froelicher; Daniel B Mark; Ben D McCallister; Aryan N Mooss; Michael G O'Reilly; William L Winters; Raymond J Gibbons; Elliott M Antman; Joseph S Alpert; David P Faxon; Valentin Fuster; Gabriel Gregoratos; Loren F Hiratzka; Alice K Jacobs; Richard O Russell; Sidney C Smith
Journal:  Circulation       Date:  2002-10-01       Impact factor: 29.690

3.  Stress protocols and tracers.

Authors:  Milena J Henzlova; Manuel D Cerqueira; John J Mahmarian; Siu-Sun Yao
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

4.  Clinical results of a novel wide beam reconstruction method for shortening scan time of Tc-99m cardiac SPECT perfusion studies.

Authors:  Salvador Borges-Neto; Robert A Pagnanelli; Linda K Shaw; Emily Honeycutt; Shuli C Shwartz; George L Adams; Ralph Edward Coleman
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

5.  Incremental prognostic value of myocardial perfusion single photon emission computed tomography for the prediction of cardiac death: differential stratification for risk of cardiac death and myocardial infarction.

Authors:  R Hachamovitch; D S Berman; L J Shaw; H Kiat; I Cohen; J A Cabico; J Friedman; G A Diamond
Journal:  Circulation       Date:  1998-02-17       Impact factor: 29.690

6.  Ordered subset expectation maximization and wide beam reconstruction "half-time" gated myocardial perfusion SPECT functional imaging: a comparison to "full-time" filtered backprojection.

Authors:  E Gordon DePuey; Ramesh Gadiraju; John Clark; Linda Thompson; Frank Anstett; Shuli C Shwartz
Journal:  J Nucl Cardiol       Date:  2008-04-24       Impact factor: 5.952

7.  Comparison of the short-term survival benefit associated with revascularization compared with medical therapy in patients with no prior coronary artery disease undergoing stress myocardial perfusion single photon emission computed tomography.

Authors:  Rory Hachamovitch; Sean W Hayes; John D Friedman; Ishac Cohen; Daniel S Berman
Journal:  Circulation       Date:  2003-05-27       Impact factor: 29.690

8.  Wide beam reconstruction "quarter-time" gated myocardial perfusion SPECT functional imaging: a comparison to "full-time" ordered subset expectation maximum.

Authors:  E Gordon DePuey; Srinivas Bommireddipalli; John Clark; Linda Thompson; Yossi Srour
Journal:  J Nucl Cardiol       Date:  2009-06-17       Impact factor: 5.952

9.  A multicenter evaluation of a new post-processing method with depth-dependent collimator resolution applied to full-time and half-time acquisitions without and with simultaneously acquired attenuation correction.

Authors:  Carmelo V Venero; Gary V Heller; Timothy M Bateman; A Iain McGhie; Alan W Ahlberg; Deborah Katten; Staci A Courter; Robert J Golub; James A Case; S James Cullom
Journal:  J Nucl Cardiol       Date:  2009-07-07       Impact factor: 5.952

10.  Multicenter investigation comparing a highly efficient half-time stress-only attenuation correction approach against standard rest-stress Tc-99m SPECT imaging.

Authors:  Timothy M Bateman; Gary V Heller; A Iain McGhie; Staci A Courter; Robert A Golub; James A Case; S James Cullom
Journal:  J Nucl Cardiol       Date:  2009-06-23       Impact factor: 5.952

View more
  9 in total

1.  Advances in SPECT camera software and hardware: currently available and new on the horizon.

Authors:  E Gordon DePuey
Journal:  J Nucl Cardiol       Date:  2012-06       Impact factor: 5.952

Review 2.  Recent advances in cardiac SPECT instrumentation and system design.

Authors:  Mark F Smith
Journal:  Curr Cardiol Rep       Date:  2013-08       Impact factor: 2.931

3.  Contemporary Cardiac SPECT Imaging-Innovations and Best Practices: An Information Statement from the American Society of Nuclear Cardiology.

Authors:  Brian G Abbott; James A Case; Sharmila Dorbala; Andrew J Einstein; James R Galt; Robert Pagnanelli; Renée P Bullock-Palmer; Prem Soman; R Glenn Wells
Journal:  J Nucl Cardiol       Date:  2018-10       Impact factor: 5.952

4.  Advances in image reconstruction software in nuclear cardiology: Is all that glitters gold?

Authors:  Claudio Marcassa; Orazio Zoccarato
Journal:  J Nucl Cardiol       Date:  2016-05-24       Impact factor: 5.952

5.  Proof of concept for low-dose molecular breast imaging with a dual-head CZT gamma camera. Part I. Evaluation in phantoms.

Authors:  Carrie B Hruska; Amanda L Weinmann; Michael K O'Connor
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

6.  Myocardial perfusion imaging with a solid-state camera: simulation of a very low dose imaging protocol.

Authors:  Ryo Nakazato; Daniel S Berman; Sean W Hayes; Mathews Fish; Richard Padgett; Yuan Xu; Mark Lemley; Rafael Baavour; Nathaniel Roth; Piotr J Slomka
Journal:  J Nucl Med       Date:  2013-01-15       Impact factor: 10.057

Review 7.  Taking the perfect nuclear image: quality control, acquisition, and processing techniques for cardiac SPECT, PET, and hybrid imaging.

Authors:  James A Case; Timothy M Bateman
Journal:  J Nucl Cardiol       Date:  2013-10       Impact factor: 5.952

Review 8.  Recent trends in nuclear cardiology practice.

Authors:  Kyoung Sook Won; Bong-Il Song
Journal:  Chonnam Med J       Date:  2013-08-22

9.  Technical note: Partitioning of gated single photon emission computed tomography raw data for protocols optimization.

Authors:  Cleiton Cavalcante Queiroz; Marcos Antonio Dorea Machado; Antonio Augusto Brito Ximenes; Andre Gustavo Silva Pino; Eduardo Martins Netto
Journal:  J Appl Clin Med Phys       Date:  2021-12-17       Impact factor: 2.102

  9 in total