Literature DB >> 23864146

Integrating Retraction Modeling Into an Atlas-Based Framework for Brain Shift Prediction.

Ishita Chen, Rowena E Ong, Amber L Simpson, Kay Sun, Reid C Thompson, Michael I Miga.   

Abstract

In recent work, an atlas-based statistical model for brain shift prediction, which accounts for uncertainty in the intraoperative environment, has been proposed. Previous work reported in the literature using this technique did not account for local deformation caused by surgical retraction. It is challenging to precisely localize the retractor location prior to surgery and the retractor is often moved in the course of the procedure. This paper proposes a technique that involves computing the retractor-induced brain deformation in the operating room through an active model solve and linearly superposing the solution with the precomputed deformation atlas. As a result, the new method takes advantage of the atlas-based framework's accounting for uncertainties while also incorporating the effects of retraction with minimal intraoperative computing. This new approach was tested using simulation and phantom experiments. The results showed an improvement in average shift correction from 50% (ranging from 14 to 81%) for gravity atlas alone to 80% using the active solve retraction component (ranging from 73 to 85%). This paper presents a novel yet simple way to integrate retraction into the atlas-based brain shift computation framework.

Entities:  

Mesh:

Year:  2013        PMID: 23864146      PMCID: PMC4411214          DOI: 10.1109/TBME.2013.2272658

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  18 in total

1.  Modeling of retraction and resection for intraoperative updating of images.

Authors:  M I Miga; D W Roberts; F E Kennedy; L A Platenik; A Hartov; K E Lunn; K D Paulsen
Journal:  Neurosurgery       Date:  2001-07       Impact factor: 4.654

2.  Model-driven brain shift compensation.

Authors:  Oskar Skrinjar; Arya Nabavi; James Duncan
Journal:  Med Image Anal       Date:  2002-12       Impact factor: 8.545

3.  In vivo quantification of retraction deformation modeling for updated image-guidance during neurosurgery.

Authors:  Leah A Platenik; Michael I Miga; David W Roberts; Karen E Lunn; Francis E Kennedy; Alex Hartov; Keith D Paulsen
Journal:  IEEE Trans Biomed Eng       Date:  2002-08       Impact factor: 4.538

4.  Cortical surface tracking using a stereoscopic operating microscope.

Authors:  Hai Sun; David W Roberts; Hany Farid; Ziji Wu; Alex Hartov; Keith D Paulsen
Journal:  Neurosurgery       Date:  2005-01       Impact factor: 4.654

5.  An atlas-based method to compensate for brain shift: preliminary results.

Authors:  Prashanth Dumpuri; Reid C Thompson; Benoit M Dawant; A Cao; Michael I Miga
Journal:  Med Image Anal       Date:  2007-03-01       Impact factor: 8.545

6.  Intraoperative brain shift and deformation: a quantitative analysis of cortical displacement in 28 cases.

Authors:  D W Roberts; A Hartov; F E Kennedy; M I Miga; K D Paulsen
Journal:  Neurosurgery       Date:  1998-10       Impact factor: 4.654

7.  Intraoperative cortical surface characterization using laser range scanning: preliminary results.

Authors:  Tuhin K Sinha; Michael I Miga; David M Cash; Robert J Weil
Journal:  Neurosurgery       Date:  2006-10       Impact factor: 4.654

8.  Quantification of, visualization of, and compensation for brain shift using intraoperative magnetic resonance imaging.

Authors:  C Nimsky; O Ganslandt; S Cerny; P Hastreiter; G Greiner; R Fahlbusch
Journal:  Neurosurgery       Date:  2000-11       Impact factor: 4.654

9.  Patient-specific model of brain deformation: application to medical image registration.

Authors:  Adam Wittek; Karol Miller; Ron Kikinis; Simon K Warfield
Journal:  J Biomech       Date:  2006-05-06       Impact factor: 2.712

10.  A mobile computed tomographic scanner with intraoperative and intensive care unit applications.

Authors:  W E Butler; C M Piaggio; C Constantinou; L Niklason; R G Gonzalez; G R Cosgrove; N T Zervas
Journal:  Neurosurgery       Date:  1998-06       Impact factor: 4.654

View more
  5 in total

1.  Toward a generic real-time compression correction framework for tracked ultrasound.

Authors:  Thomas S Pheiffer; Michael I Miga
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-04-23       Impact factor: 2.924

2.  Android application for determining surgical variables in brain-tumor resection procedures.

Authors:  Rohan C Vijayan; Reid C Thompson; Lola B Chambless; Peter J Morone; Le He; Logan W Clements; Rebekah H Griesenauer; Hakmook Kang; Michael I Miga
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-02

Review 3.  Computational Modeling for Enhancing Soft Tissue Image Guided Surgery: An Application in Neurosurgery.

Authors:  Michael I Miga
Journal:  Ann Biomed Eng       Date:  2015-09-09       Impact factor: 3.934

4.  Retrospective study comparing model-based deformation correction to intraoperative magnetic resonance imaging for image-guided neurosurgery.

Authors:  Ma Luo; Sarah F Frisken; Jared A Weis; Logan W Clements; Prashin Unadkat; Reid C Thompson; Alexandra J Golby; Michael I Miga
Journal:  J Med Imaging (Bellingham)       Date:  2017-09-13

Review 5.  Intraoperative Imaging Modalities and Compensation for Brain Shift in Tumor Resection Surgery.

Authors:  Siming Bayer; Andreas Maier; Martin Ostermeier; Rebecca Fahrig
Journal:  Int J Biomed Imaging       Date:  2017-06-05
  5 in total