Literature DB >> 23857073

Application of a novel metal artifact correction algorithm in flat-panel CT after coil embolization of brain aneurysms: intraindividual comparison.

J-H Buhk1, M Groth, S Sehner, J Fiehler, N O Schmidt, U Grzyska.   

Abstract

PURPOSE: To evaluate a novel algorithm for correcting beam hardening artifacts caused by metal implants in computed tomography performed on a C-arm angiography system equipped with a flat panel (FP-CT).
MATERIALS AND METHODS: 16 datasets of cerebral FP-CT acquisitions after coil embolization of brain aneurysms in the context of acute subarachnoid hemorrhage have been reconstructed by applying a soft tissue kernel with and without a novel reconstruction filter for metal artifact correction. Image reading was performed in multiplanar reformations (MPR) in average mode on a dedicated radiological workplace in comparison to the preinterventional native multisection CT (MS-CT) scan serving as the anatomic gold standard. Two independent radiologists performed image scoring following a defined scale in direct comparison of the image data with and without artifact correction. For statistical analysis, a random intercept model was calculated.
RESULTS: The inter-rater agreement was very high (ICC = 86.3 %). The soft tissue image quality and visualization of the CSF spaces at the level of the implants was substantially improved. The additional metal artifact correction algorithm did not induce impairment of the subjective image quality in any other brain regions.
CONCLUSION: Adding metal artifact correction to FP-CT in an acute postinterventional setting helps to visualize the close vicinity of the aneurysm at a generally consistent image quality. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23857073     DOI: 10.1055/s-0033-1350117

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  5 in total

1.  Evaluation of a metal artifact reduction algorithm applied to post-interventional flat detector CT in comparison to pre-treatment CT in patients with acute subarachnoid haemorrhage.

Authors:  Angelika Mennecke; Stanislav Svergun; Bernhard Scholz; Kevin Royalty; Arnd Dörfler; Tobias Struffert
Journal:  Eur Radiol       Date:  2016-04-16       Impact factor: 5.315

2.  A Patient Dose-Reduction Technique for Neuroendovascular Image-Guided Interventions: Image-Quality Comparison Study.

Authors:  A Sonig; S V Setlur Nagesh; V S Fennell; S Gandhi; L Rangel-Castilla; C N Ionita; K V Snyder; L N Hopkins; D R Bednarek; S Rudin; A H Siddiqui; E I Levy
Journal:  AJNR Am J Neuroradiol       Date:  2018-02-15       Impact factor: 3.825

3.  Evaluation of a prototype correction algorithm to reduce metal artefacts in flat detector computed tomography of scaphoid fixation screws.

Authors:  Lukas Filli; Magda Marcon; Bernhard Scholz; Maurizio Calcagni; Tim Finkenstädt; Gustav Andreisek; Roman Guggenberger
Journal:  Skeletal Radiol       Date:  2014-08-28       Impact factor: 2.199

4.  Evaluation of an optimized metal artifact reduction algorithm for flat-detector angiography compared to DSA imaging in follow-up after neurovascular procedures.

Authors:  Nadine Amelung; Volker Maus; Daniel Behme; Ismini E Papageorgiou; Johanna Rosemarie Leyhe; Michael Knauth; Marios Nikos Psychogios
Journal:  BMC Med Imaging       Date:  2019-08-14       Impact factor: 1.930

5.  Metal artifact reduction for flat panel detector intravenous CT angiography in patients with intracranial metallic implants after endovascular and surgical treatment.

Authors:  Rastislav Pjontek; Belgin Önenköprülü; Bernhard Scholz; Yiannis Kyriakou; Gerrit A Schubert; Omid Nikoubashman; Ahmed Othman; Martin Wiesmann; Marc A Brockmann
Journal:  J Neurointerv Surg       Date:  2015-09-07       Impact factor: 5.836