Literature DB >> 2384485

Accuracy of determining the point of force application with piezoelectric force plates.

M F Bobbert1, H C Schamhardt.   

Abstract

The accuracy of determining the point of force application with piezoelectric force plates, as specified by the manufacturer, is lower than needed for certain applications. The purpose of this study was to evaluate the accuracy of a commonly used plate (KISTLER type 9287) and to improve it by proposing a correction algorithm. Forces were applied to a wooden board, supported in one corner by a stylus that rested on the force plate. To determine the influence of position and magnitude of the force vector, the stylus was placed on 117 different locations, and calibrated masses were used to exert vertical forces between 0 and 2000 N. To determine the influence of loading rate, dynamic tests were performed in which a subject ran across the board. In static tests at a given stylus position with actual coordinates x (short axis) and y (long axis), it was found that the calculated coordinates x and y of the point of force application had virtually constant values at forces above 1000 N. In dynamic tests, oscillations could occur in x and y with an amplitude of more than 20 mm. When these were avoided or removed by filtering, static and dynamic tests at a given stylus position showed the same values for x and y at forces above 1000 N. Across stylus positions, the errors x-x and y-y (measured at 1600 N) ranged from -20 to +20 mm. The average over 117 points of the absolute errors magnitude of x-x and magnitude of y-y amounted to 3.5 and 6.3 mm, respectively (mean values of three plates).(ABSTRACT TRUNCATED AT 250 WORDS)

Mesh:

Year:  1990        PMID: 2384485     DOI: 10.1016/0021-9290(90)90169-4

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  9 in total

1.  Instrumented staircase for ground reaction measurement.

Authors:  R Riener; M Rabuffetti; C Frigo; J Quintern; G Schmidt
Journal:  Med Biol Eng Comput       Date:  1999-07       Impact factor: 2.602

2.  Periodical in-situ re-calibration of force platforms: a new method for the robust estimation of the calibration matrix.

Authors:  A Cappello; D Lenzi; L Chiari
Journal:  Med Biol Eng Comput       Date:  2004-05       Impact factor: 2.602

3.  Spatial synchronization of an insole pressure distribution system with a 3D motion analysis system for center of pressure measurements.

Authors:  Laetitia Fradet; Johannes Siegel; Marieke Dahl; Merkur Alimusaj; Sebastian I Wolf
Journal:  Med Biol Eng Comput       Date:  2008-08-26       Impact factor: 2.602

Review 4.  Methodological factors affecting joint moments estimation in clinical gait analysis: a systematic review.

Authors:  Valentina Camomilla; Andrea Cereatti; Andrea Giovanni Cutti; Silvia Fantozzi; Rita Stagni; Giuseppe Vannozzi
Journal:  Biomed Eng Online       Date:  2017-08-18       Impact factor: 2.819

5.  Intra-session test-retest reliability of magnitude and structure of center of pressure from the Nintendo Wii Balance Board™ for a visually impaired and normally sighted population.

Authors:  Pamela E Jeter; Jiangxia Wang; Jialiang Gu; Michael P Barry; Crystal Roach; Marilyn Corson; Lindsay Yang; Gislin Dagnelie
Journal:  Gait Posture       Date:  2014-12-04       Impact factor: 2.840

6.  Concurrent word generation and motor performance: further evidence for language-motor interaction.

Authors:  Amy D Rodriguez; Matthew L McCabe; Joe R Nocera; Jamie Reilly
Journal:  PLoS One       Date:  2012-05-15       Impact factor: 3.240

7.  Spot check of the calibrated force platform location.

Authors:  M Rabuffetti; M Ferrarin; F Benvenuti
Journal:  Med Biol Eng Comput       Date:  2001-11       Impact factor: 3.079

8.  Differences in center of pressure trajectory between normal and steppage gait.

Authors:  Nima Jamshidi; Mostafa Rostami; Siamak Najarian; Mohammad Bagher Menhaj; Mohammad Saadatnia; Firooz Salami
Journal:  J Res Med Sci       Date:  2010-01       Impact factor: 1.852

Review 9.  Monitoring Neuromuscular Performance in Military Personnel.

Authors:  Justin J Merrigan; Jason D Stone; Andrew G Thompson; W Guy Hornsby; Joshua A Hagen
Journal:  Int J Environ Res Public Health       Date:  2020-12-07       Impact factor: 3.390

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.