| Literature DB >> 35706854 |
Nopadol Precha1, Chayada Rattanaphan1, Tanyaporn Galiga1, Presert Makkaew1, Nutcha Narom1, Siriuma Jawjit1.
Abstract
Background: The bacteriological quality of drinking water has become a public health concern according to its association with water-borne diseases. Nowadays, there are several different types of drinking water, including water cooler dispensers (WCDs), which are becoming a popular device in educational institutions. Therefore, this study aims to determine the bacteriological quality of drinking water from WCDs, and inspect their hygienic conditions in students' dormitories at a university in Nakhon Si Thammarat, Thailand.Entities:
Keywords: Drinking water; environmental monitoring; hygiene; water quality
Year: 2022 PMID: 35706854 PMCID: PMC9188901 DOI: 10.4103/ijpvm.IJPVM_644_20
Source DB: PubMed Journal: Int J Prev Med ISSN: 2008-7802
The results of bacteriological analysis of drinking water from WCDs
| Water quality parameters | Range ( | Drinking water quality Std* |
|---|---|---|
| Total coliform bacteria (MPN/100 mL) | 2.2-17 | <2.2 |
| Fecal coliform bacteria (MPN/100 mL) | 2.2-34 | <2.2 |
|
| Detected | nd† |
WCDs=Water cooler dispensers. *Reference from Thai Industrial Standards Institute (2006). †nd=Non-detected in 100 mL of water samples
Assessment of hygienic conditions of the drinking water dispenser machines (n=53)
| Items | WCDs evaluation* | |
|---|---|---|
|
| ||
| Satisfactory | Unsatisfactory | |
| Location: | ||
| 1. The location should be away from dust particles, water drainage, and garbage at least 30 m | 28 (52.83) | 25 (47.17) |
| 2. The location was not wet and unsanitary condition around the water dispenser machines and have proper water drainage | 43 (81.13) | 10 (18.87) |
| 3. The dispenser machines should be covered with a cap on the inlet to prevent insects | 45 (84.91) | 8 (15.09) |
| 4. The dispenser machines were installed at least 10 cm above the ground as indicated by stability | 38 (71.70) | 15 (28.30) |
| 5. There is the electric system to prevent a short-circuit and equipment grounding conductor | 53 (100) | 0 (0.00) |
| 6. Should be provided the container above the ground properly | 53 (100) | 0 (0.00) |
| Features of machine: | ||
| 7. The machines inspected had no rusted, stability, to prevent short-circuit | 53 (100) | 0 (0.00) |
| 8. Parts exposed directly to the water were made of the materials used with food, without odor, color, or taste that may affect water quality | 53 (100) | 0 (0.00) |
| 9. The water faucet was at least 60 cm above the ground | 53 (100) | 0 (0.00) |
| 10. Parts exposed directly to the water were not presented thallophytic plants or any unsanitary | 40 (75.47) | 13 (24.53) |
| Water resources and quality improvement: | ||
| 11. Water resources were satisfactory being clean such as water supply and groundwater | 53 (100) | 0 (0.00) |
| Drinking water standardized quality control: | ||
| 12. Water sampling to test for physical characteristic, chemical characteristic and bacteria at least 1 time/year | 53 (100) | 0 (0.00) |
| Maintenance and cleaning: | ||
| 13. Cleaning the machines setting every day to prevent dust was spreading | 0 (0.00) | 53 (100) |
| 14. Cleaning the outlet and water container every day to prevent dust was spreading | 0 (0.00) | 53 (100) |
| 15. Cleaning water storage at least 1 time/month | 0 (0.00) | 53 (100) |
| 16. Cleaning and change filter membrane according to the machine company | 0 (0.00) | 53 (100) |
| Monitoring | ||
| 17. Water quality record and Maintenance record by specify performance details | 0 (0.00) | 53 (100) |
| 18. Show the information of water quality for customers | 0 (0.00) | 53 (100) |
WCDs=Water cooler dispensers. *Reference from Business Detrimental to Health, in the Public Health Act 1992 and the Ministry of Public Health announcement (no. 362) of 2013
The correlation analysis of hygienic condition and fecal coliform
| Hygienic conditions | Correlation coefficient ( | 95% CI for |
|
|---|---|---|---|
| The location should be away from dust particles, water drainage and garbage at least 30 m | 0.139 | 0.001-0.278 | 0.05 |
| The location was not wet and unsanitary condition around the water dispenser machines and have proper water drainage | 0.566 | 0.338-0.794 | <0.0001 |
| Parts exposed directly to the water were not presented thallophytic plants or any unsanitary | -0.068 | -0.197-0.061 | 0.303 |
CI=Confidence interval