Literature DB >> 23828621

A multimodal approach in total hip arthroplasty preoperative templating.

Massimiliano Marcucci1, Pier Francesco Indelli, Leonardo Latella, Paolo Poli, Devin King.   

Abstract

OBJECTIVES: Accurate preoperative planning is mandatory for a successful total hip arthroplasty (THA). Templating helps to achieve multiple technical goals, including offset restoration, leg-length equality, and components positioning. This study aims to measure how successful a new stepwise method for preoperative radiographic templating is in achieving postoperative restoration of anatomy.
METHODS: We measured the relationship of several radiographic landmarks on the affected limb in comparison to the unaffected limb to define the appropriate position of the components. One hundred consecutive patients with unilateral disease undergoing THA were retrospectively analyzed. The preoperative templates were compared with the postoperative radiographs.
RESULTS: Accuracy in achieving the desired offset, leg-length discrepancy within 5 mm, was 93 % and 100 % respectively. Acetabular component positioning within 2° was replicated in 92 %.
CONCLUSION: We conclude that this technique can help the surgeon to accurately reproduce the anatomy of the contralateral unaffected hip.

Entities:  

Mesh:

Year:  2013        PMID: 23828621     DOI: 10.1007/s00256-013-1677-5

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  30 in total

1.  [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses].

Authors:  N A Ramaniraka; L R Rakotomanana; P J Rubin; P Leyvraz
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  2000-10

2.  Intraoperative radiographs for placing acetabular components in hip resurfacing arthroplasty.

Authors:  Thomas P Gross; Fei Liu; Lee Webb
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

3.  Digital templating in total hip arthroplasty.

Authors:  James V Bono
Journal:  J Bone Joint Surg Am       Date:  2004       Impact factor: 5.284

4.  Preoperative templating and biomechanics in total hip arthroplasty.

Authors:  Thomas P Schmalzried
Journal:  Orthopedics       Date:  2005-08       Impact factor: 1.390

5.  A systematic approach to the plain radiographic evaluation of the young adult hip.

Authors:  John C Clohisy; John C Carlisle; Paul E Beaulé; Young-Jo Kim; Robert T Trousdale; Rafael J Sierra; Michael Leunig; Perry L Schoenecker; Michael B Millis
Journal:  J Bone Joint Surg Am       Date:  2008-11       Impact factor: 5.284

6.  The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty.

Authors:  Alejandro González Della Valle; Gastón Slullitel; Francisco Piccaluga; Eduardo A Salvati
Journal:  J Arthroplasty       Date:  2005-01       Impact factor: 4.757

7.  Effect of femoral component offset on polyethylene wear in total hip arthroplasty.

Authors:  D P Sakalkale; P F Sharkey; K Eng; W J Hozack; R H Rothman
Journal:  Clin Orthop Relat Res       Date:  2001-07       Impact factor: 4.176

8.  Postoperative sciatic and femoral nerve palsy with reference to leg lengthening and medialization/lateralization of the hip joint following total hip arthroplasty.

Authors:  O A Nercessian; F Piccoluga; N S Eftekhar
Journal:  Clin Orthop Relat Res       Date:  1994-07       Impact factor: 4.176

Review 9.  The pants too short, the leg too long!

Authors:  C S Ranawat
Journal:  Orthopedics       Date:  1999-09       Impact factor: 1.390

10.  A new digital preoperative planning method for total hip arthroplasties.

Authors:  Hendrikus J A Crooijmans; Armand M R P Laumen; Carola van Pul; Jan B A van Mourik
Journal:  Clin Orthop Relat Res       Date:  2008-09-10       Impact factor: 4.176

View more
  10 in total

1.  Templating in uncemented total hip arthroplasty-on intra- and interobserver reliability and professional experience.

Authors:  Nils J Strøm; Are Hugo Pripp; Olav Reikerås
Journal:  Ann Transl Med       Date:  2017-02

2.  Dual-position calibration markers for total hip arthroplasty: theoretical comparison to fixed calibration and single marker method.

Authors:  Christoph Kolja Boese; Sebastian Wilhelm; Stefan Haneder; Philipp Lechler; Peer Eysel; Jan Bredow
Journal:  Int Orthop       Date:  2018-06-20       Impact factor: 3.075

3.  Digital templating without a calibration marker is accurate at predicting implant size for hip hemiarthroplasty.

Authors:  Mina Derias; Muhammad A Khan; Jamie Buchanan
Journal:  Eur J Trauma Emerg Surg       Date:  2018-09-12       Impact factor: 3.693

4.  Clinical outcome of design modifications to the CLS Spotorno Stem in total hip replacement.

Authors:  Angelo Graceffa; Pier Francesco Indelli; Leonardo Latella; Paolo Poli; Alexander Fulco; Massimiliano Marcucci
Journal:  Joints       Date:  2016-09-21

Review 5.  Computed tomography for preoperative planning in total hip arthroplasty: what radiologists need to know.

Authors:  Alexander Huppertz; Sebastian Radmer; Moritz Wagner; Torsten Roessler; Bernd Hamm; Martin Sparmann
Journal:  Skeletal Radiol       Date:  2014-03-13       Impact factor: 2.199

6.  Templating in uncemented THA. On accuracy and postoperative leg length discrepancy.

Authors:  Nils J Strøm; Olav Reikerås
Journal:  J Orthop       Date:  2018-01-17

7.  CORR Insights®: The External Obturator Footprint Is a Usable, Accurate, and Reliable Landmark for Stem Depth in Direct Anterior THA.

Authors:  Lucian Bogdan Solomon
Journal:  Clin Orthop Relat Res       Date:  2021-08-01       Impact factor: 4.755

8.  A Novel Method of Determining Acetabular Component Size to Guide Explant in Revision Hip Arthroplasty.

Authors:  Fiachra O Deasmhunaigh; Jeremy Abetz; Shaun English; David Mitchell; Biswadev Mitra
Journal:  Arthroplast Today       Date:  2020-04-24

9.  Implications of component size and calibration error on digital templating for total hip arthroplasty. A visual matrix from a simple mathematical model.

Authors:  Christoph Kolja Boese; Tim Rolvien; Matthias Trost; Michael Frink; Jan Hubert; Frank Timo Beil; Christian Ries
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-04-17       Impact factor: 2.924

10.  The External Obturator Footprint Is a Usable, Accurate, and Reliable Landmark for Stem Depth in Direct Anterior THA.

Authors:  Georges Vles; Alexander Meynen; Jef De Mulder; Stijn Ghijselings
Journal:  Clin Orthop Relat Res       Date:  2021-08-01       Impact factor: 4.755

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.