Literature DB >> 23824387

Long-term performance of ceramic and metal femoral heads on conventional polyethylene in young and active patients: a matched-pair analysis.

Morteza Meftah1, Gregory G Klingenstein, Richard J Yun, Amar S Ranawat, Chitranjan S Ranawat.   

Abstract

BACKGROUND: Ceramic femoral heads produce less wear of the opposing polyethylene than do metal femoral heads in wear simulation studies. This is a matched-pair analysis of the wear of ceramic and metal femoral heads on conventional polyethylene in uncemented total hip replacements in young, active patients at a minimum of fifteen years of follow-up.
METHODS: From June 1989 to May 1992, thirty-one matched pairs of alumina ceramic or cobalt-chromium metal femoral heads were identified. Patients were matched on the basis of age, sex, body weight, diagnosis, and activity level. The mean age was 55 ± 9 years (range, twenty-three to sixty-five years) at the time of surgery. All procedures were performed with a posterolateral surgical approach by a single surgeon using press-fit Ranawat-Bernstein femoral stems, Harris-Galante-II acetabular cups, GUR 4150 conventional polyethylene (sterilized in argon), and 28-mm-diameter femoral heads. Wear measurements were performed by two independent observers using the computer-assisted Roman software.
RESULTS: The average duration of follow-up was 17 ± 1.7 years (range, fifteen to twenty years). The mean Hospital for Special Surgery hip scores (and standard deviation) in the ceramic and metal groups were 39 ± 4 and 40 ± 3 at the time of final follow-up. The University of California Los Angeles activity score at the time of the final follow-up was 6 ± 2 for both groups. The mean wear rates for the ceramic group and the metal group were 0.086 ± 0.05 mm/yr and 0.137 ± 0.05 mm/yr, respectively (p = 0.0015). There was one reoperation in the ceramic group because of distal femoral osteolysis. There were three failures in the metal group, requiring isolated liner exchange in two hips and revision of the acetabular component in one hip because of wear-induced osteolysis and/or loosening that caused symptoms. Five hips in the ceramic group and six hips in the metal group had radiographic evidence of acetabular or femoral osteolysis, but none were symptomatic.
CONCLUSIONS: Ceramic femoral heads produced significantly less wear on conventional polyethylene liners at the time of long-term follow-up than did metal heads in this matched-pair analysis of young and active patients with uncemented fixation.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23824387     DOI: 10.2106/JBJS.L.00432

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  17 in total

1.  Minimum five-year wear rate of metal-on-highly cross-linked polyethylene in primary total hip arthroplasty.

Authors:  Caroline Scemama; Claudio Dora; Jean Langlois; Moussa Hamadouche
Journal:  Int Orthop       Date:  2014-12-04       Impact factor: 3.075

2.  Third generation delta ceramic-on-ceramic bearing for total hip arthroplasty at mid-term follow-up.

Authors:  Alessandro Bistolfi; Riccardo Ferracini; Alessandro Aprato; Alessandro Massè; Walter Daghino; Sara Lea; Stefano Artiaco; Gwo-Chin Lee
Journal:  J Orthop       Date:  2020-08-28

3.  Gender Differences in Wear Rates for 28- vs 32-mm Ceramic Femoral Heads on Modern Highly Cross-linked Polyethylene at Midterm Follow-Up in Young Patients Undergoing Total Hip Arthroplasty.

Authors:  Jeffrey B Stambough; Gail Pashos; Ningying Wu; Jacob A Haynes; John M Martell; John C Clohisy
Journal:  J Arthroplasty       Date:  2015-10-28       Impact factor: 4.757

4.  Mid-term result of ceramic bearings in total hip arthroplasty.

Authors:  Ismail Remzi Tozun; Vahit Emre Ozden; Goksel Dikmen; Burak Beksac
Journal:  Int Orthop       Date:  2014-06-01       Impact factor: 3.075

5.  Short stem shoulder replacement.

Authors:  Simon N Bell; Jennifer A Coghlan
Journal:  Int J Shoulder Surg       Date:  2014-07

6.  Harmine Alleviates Titanium Particle-Induced Inflammatory Bone Destruction by Immunomodulatory Effect on the Macrophage Polarization and Subsequent Osteogenic Differentiation.

Authors:  Liangliang Wang; Qing Wang; Wei Wang; Gaoran Ge; Nanwei Xu; Dong Zheng; Shijie Jiang; Gongyin Zhao; Yaozeng Xu; Yuji Wang; Ruixia Zhu; Dechun Geng
Journal:  Front Immunol       Date:  2021-05-17       Impact factor: 7.561

7.  Long-term durability of alumina ceramic heads in THA.

Authors:  Nicholas A Beckmann; Tobias Gotterbarm; Moritz M Innmann; Christian Merle; Thomas Bruckner; J Philippe Kretzer; Marcus R Streit
Journal:  BMC Musculoskelet Disord       Date:  2015-09-12       Impact factor: 2.362

8.  Clinical outcomes assessment of three similar hip arthroplasty bearing surfaces.

Authors:  Christopher Parsons; Ryan Batson; Shane Reighard; Stephanie Tanner; Becky Snider; Thomas B Pace
Journal:  Orthop Rev (Pavia)       Date:  2014-05-22

9.  Catastrophic Failure of the Acetabular Polyethylene Liner in Ceramic-on-Polyethylene Total Hip Arthroplasty.

Authors:  Givenchy Manzano; Rayna A C Levin; Michael B Mayor; Ran Schwarzkopf
Journal:  J Orthop Case Rep       Date:  2014 Apr-Jun

10.  Are PEEK-on-Ceramic Bearings an Option for Total Disc Arthroplasty? An In Vitro Tribology Study.

Authors:  Ryan Siskey; Lauren Ciccarelli; Melissa K C Lui; Steven M Kurtz
Journal:  Clin Orthop Relat Res       Date:  2016-11       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.