Literature DB >> 23823738

Effect of crown to implant ratio and implant dimensions on periimplant stress of splinted implant-supported crowns: a finite element analysis.

Mehmet Bayraktar1, B Alper Gultekin, Serdar Yalcin, Eitan Mijiritsky.   

Abstract

PURPOSE: To assess the influence of different crown-implant (C/I) ratios and implant dimensions on periimplant stress in the partially edentulous posterior mandible by 3-dimensional finite element analysis (FEA).
MATERIALS AND METHODS: Two implants were placed in the second premolar and first molar regions of the mandibular model. The implants were then splinted with a 2-unit fixed bridge. The influence of 3 parameters (C/I ratio, implant length, and implant diameter) on periimplant bone stress was then analyzed by using FEA.
RESULTS: C/I ratios showed a direct relationship with periimplant bone stress, but the absolute height of the clinical crown had a much more significant influence. The implant length had less influence on the periimplant bone stress than the implant diameter. Lower stress values were detected in wide-diameter implants, even in scenarios involving long crowns.
CONCLUSIONS: Crown height is a more important factor affecting the periimplant bone stress than the C/I ratio for splinted implant-supported crowns. Two-unit fixed restorations with high C/I ratios may be successfully used with wide-diameter implants in the posterior mandible.

Mesh:

Substances:

Year:  2013        PMID: 23823738     DOI: 10.1097/ID.0b013e31829c224d

Source DB:  PubMed          Journal:  Implant Dent        ISSN: 1056-6163            Impact factor:   2.454


  4 in total

1.  Impact of peri-implant bone resorption, prosthetic materials, and crown to implant ratio on the stress distribution of short implants: a finite element analysis.

Authors:  Pinar Ercal; Aysegul Erten Taysi; Demet Cagil Ayvalioglu; Meltem Mert Eren; Soner Sismanoglu
Journal:  Med Biol Eng Comput       Date:  2021-03-17       Impact factor: 2.602

2.  Clinical evaluation of the stability of implants placed at different supracrestal levels.

Authors:  B Alper Gultekin; Ali Sirali; Pinar Gultekin; Selim Ersanli
Journal:  J Istanb Univ Fac Dent       Date:  2016-10-01

3.  Three-dimensional finite element analysis of extra short implants focusing on implant designs and materials.

Authors:  Haruka Araki; Tamaki Nakano; Shinji Ono; Hirofumi Yatani
Journal:  Int J Implant Dent       Date:  2020-01-29

4.  Biomechanical finite element analysis of short-implant-supported, 3-unit, fixed CAD/CAM prostheses in the posterior mandible.

Authors:  Lana Zupancic Cepic; Martin Frank; Andreas Reisinger; Dieter Pahr; Werner Zechner; Andreas Schedle
Journal:  Int J Implant Dent       Date:  2022-02-11
  4 in total