ICL versus Veriflex phakic IOL for treatment of moderately high myopia: randomized paired-eye comparison.

Ahmed Awadein1, Ahmed E Habib.   

Abstract

PURPOSE: To compare the objective and subjective outcome of implantable collamer lenses (ICLs; Staar Surgical, Monrovia, CA) versus Veriflex lenses (AMO, Santa Ana, CA) for the correction of moderately high myopia.
METHODS: A prospective randomized comparative eye study was performed on 24 patients with bilateral myopia that ranged from -6 to -14.5 diopters (D). One eye was implanted with an ICL and the other eye was implanted with a Veriflex phakic intraocular lens (PIOL). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), higher-order aberrations (HOAs), contrast sensitivity, patient satisfaction, central endothelial cell count, and PIOL centration were determined 6 months after surgery
RESULTS: The logMAR UDVA and CDVA improved significantly in both groups (P < .001). There was no statistically significant difference in postoperative logMAR UDVA (P = .41) or logMAR CDVA (P = .36) between the two groups. Postoperative deviation from target refraction was -0.06 ± 0.41 D in the ICL group and -0.07 ± 0.49 D in the Veriflex group (P = .15). The difference in both induced and absolute postoperative HOAs between groups was not statistically significant. The area under the log contrast sensitivity function increased significantly in both groups postoperatively. The difference in patient satisfaction between both PIOLs was not statistically significant. A higher but statistically insignificant central endothelial cell count loss occurred in the Veriflex group (P = .11).
CONCLUSION: Both ICL and Veriflex PIOLs have equally satisfactory objective and subjective visual outcomes after surgery. Copyright 2013, SLACK Incorporated.

Entities:  

Mesh:

Year:  2013        PMID: 23820226     DOI: 10.3928/1081597X-20130617-02

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  5 in total

1.  Phakic posterior chamber intraocular lens for unilateral high myopic amblyopia in Chinese pediatric patients.

Authors:  Jing Zhang; Jin-Rong Li; Zi-Dong Chen; Min-Bin Yu; Ke-Ming Yu
Journal:  Int J Ophthalmol       Date:  2016-12-18       Impact factor: 1.779

2.  Implantable collamer lens versus iris-fixed phakic intraocular lens implantation to correct myopia: a meta-analysis.

Authors:  Guan-Lu Liang; Jing Wu; Jun-Ting Shi; Jian Liu; Feng-Ying He; Wen Xu
Journal:  PLoS One       Date:  2014-08-12       Impact factor: 3.240

3.  Short-time evaluation on intraocular scattering after implantable collamer lens implantation for correcting high myopia.

Authors:  Zhe Yu; Jun Li; Hui Song
Journal:  BMC Ophthalmol       Date:  2020-06-17       Impact factor: 2.209

4.  Optical quality after posterior chamber Phakic implantation of an intraocular Lens with a central hole (V4c implantable Collamer Lens) under different lighting conditions.

Authors:  Tianrui He; Yi Zhu; Jibo Zhou
Journal:  BMC Ophthalmol       Date:  2020-03-04       Impact factor: 2.209

5.  Visian® ICLV4c™ and Artiflex®: Comparative Analysis with the HD AnalyserTM and Integration with Subjective Performance and Anatomical Parameters.

Authors:  Pedro Manuel Baptista; Sílvia Monteiro; Ana Carolina Abreu; João Poças; Diana José; Miguel Lume; Maria do Céu Pinto
Journal:  Clin Ophthalmol       Date:  2020-12-30
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.