| Literature DB >> 23813223 |
Ahmed Alzaraa1, Dhya Al-Leswas, Wen Yuan Chung, Gianpiero Gravante, Morgan Bruno, Kevin West, Ashley Dennison, David Lloyd.
Abstract
Following transplantation, areas of hypoperfusion can be associated with metabolic changes and poor organ recovery. Our study evaluated contrast-enhanced ultrasound (CEUS) agents for the detection of such areas. Livers were collected from ten pigs, connected to extracorporeal circuits and perfused using autologous blood. After 1 and 4 h livers were scanned with an ultrasound machine following the administration of CEUS agents. Biopsies from perfused and non-perfused areas were collected. The entire parenchyma enhanced strongly on non-contrast ultrasound at 1 h with no perfusion defects. Four hours later multiple perfusion defects manifested not evident with non-contrast ultrasound. Histology confirmed non-perfused areas corresponded to ischemic zones. In our model the addition of CEUS revealed perfusion defects after 4 h. This might facilitate detection and characterization of perfusion defects in transplanted livers.Entities:
Mesh:
Substances:
Year: 2013 PMID: 23813223 DOI: 10.1007/s10047-013-0717-1
Source DB: PubMed Journal: J Artif Organs ISSN: 1434-7229 Impact factor: 1.731