Literature DB >> 19713603

Contrast-enhanced ultrasound in liver transplant: first results and potential for complications in the postoperative period.

D-A Clevert1, M Stickel, N Minaifar, F Löhe, C Graeb, K W Jauch, M Reiser.   

Abstract

PURPOSE: This study compared the efficacy of contrast-enhanced ultrasound (CEUS) using a second generation contrast medium versus CT or MRA in the assessment of vascular and biliary complications in postoperative follow-up of liver transplantation. METHODS AND MATERIALS: The study group consisted of 36 consecutive liver transplant recipients who underwent post-transplantation CEUS examination after developing ascites and/or unclear liver function tests. Real time CEUS was performed after a bolus injection of SonoVue (1.6-2.4 ml, Bracco, Imaging Germany) followed by 10 ml of saline solution. Using contrast harmonic imaging (CHI) technique (Logiq 9, GE) with a 2.5-4-MHz transducer, a low mechanical index was chosen to avoid early destruction of the microbubbles (MI 0.1-0.2). In order to confirm the results, the patients underwent contrast-enhanced MRI or CT.
RESULTS: Complications were identified in 16 of 36 patients (44.4%). Five transplants (14%) had hepatic artery thrombosis (n=2) or significant stenosis (n=3). Six transplants (16%) developed portal vein stenosis (n=4) or portal vein thrombosis (n=2). MRI or CT confirmed the findings of the CEUS in all 11 cases. Biliary stricture at the anastomotic site was detected in 5 patients. MR-CP confirmed the findings of all strictures.
CONCLUSION: Due to advances in contrast-enhanced US, vascular and biliary complications in the postoperative period following liver transplantation can be reliably diagnosed non-invasively on the intensive care unit. CEUS shows vascular as well as biliary complications in the postoperative patient with a high degree of accuracy.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19713603     DOI: 10.3233/CH-2009-1223

Source DB:  PubMed          Journal:  Clin Hemorheol Microcirc        ISSN: 1386-0291            Impact factor:   2.375


  8 in total

1.  Intraductally applied contrast-enhanced ultrasound (IA-CEUS) for evaluating obstructive disease and secretory dysfunction of the salivary glands.

Authors:  Pamela Zengel; A Berghaus; C Weiler; M Reiser; D A Clevert
Journal:  Eur Radiol       Date:  2010-12-31       Impact factor: 5.315

Review 2.  Vascular complications after adult living donor liver transplantation: Evaluation with ultrasonography.

Authors:  Lin Ma; Qiang Lu; Yan Luo
Journal:  World J Gastroenterol       Date:  2016-01-28       Impact factor: 5.742

3.  Contrast-enhanced ultrasound detects perfusion defects in an ex vivo porcine liver model: a useful tool for the study of hepatic reperfusion.

Authors:  Ahmed Alzaraa; Dhya Al-Leswas; Wen Yuan Chung; Gianpiero Gravante; Morgan Bruno; Kevin West; Ashley Dennison; David Lloyd
Journal:  J Artif Organs       Date:  2013-06-29       Impact factor: 1.731

Review 4.  Contrast-enhanced ultrasound applications in liver transplant imaging.

Authors:  Giuseppe Como; Luca Montaldo; Umberto Baccarani; Dario Lorenzin; Chiara Zuiani; Rossano Girometti
Journal:  Abdom Radiol (NY)       Date:  2021-01

5.  Is Routine Intraoperative Contrast-Enhanced Ultrasonography Useful During Whole Liver Transplantation?

Authors:  Nicolas Golse; Simone Santoni; Vincent Karam; Oriana Ciacio; Gabriella Pittau; Marc-Antoine Allard; Daniel Cherqui; Antonio Sa Cunha; René Adam; Denis Castaing; Eric Vibert
Journal:  World J Surg       Date:  2018-05       Impact factor: 3.352

Review 6.  Post-operative imaging in liver transplantation: state-of-the-art and future perspectives.

Authors:  Rossano Girometti; Giuseppe Como; Massimo Bazzocchi; Chiara Zuiani
Journal:  World J Gastroenterol       Date:  2014-05-28       Impact factor: 5.742

Review 7.  Application of contrast-enhanced ultrasound after liver transplantation: Current status and perspectives.

Authors:  Jie Ren; Tao Wu; Bo-Wen Zheng; Ying-Yi Tan; Rong-Qin Zheng; Gui-Hua Chen
Journal:  World J Gastroenterol       Date:  2016-01-28       Impact factor: 5.742

Review 8.  Contrast-enhanced ultrasound of transplant organs - liver and kidney - in children.

Authors:  Doris Franke; Reza J Daugherty; Damjana Ključevšek; Aikaterini Ntoulia; Vasileios Rafailidis; Marcelo S Takahashi; Alvaro Torres; Bernarda Viteri; Frank M Volberg
Journal:  Pediatr Radiol       Date:  2021-05-12
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.