Literature DB >> 23809379

Causes of failure with Szabo technique - an analysis of nine cases.

Rajendra Kumar Jain1, T N C Padmanabhan, Nishad Chitnis.   

Abstract

OBJECTIVE: The objective of this case series is to identify and define causes of failure of Szabo technique in rapid-exchange monorail system for ostial lesions. METHODS AND
RESULTS: From March 2009 to March 2011, 42 patients with an ostial lesion were treated percutaneously at our institution using Szabo technique in a monorail stent system. All patients received unfractionated heparin during intervention. Loading dose of clopidogrel, followed by clopidogrel and aspirin was administered. In 57% of patients, drug-eluting stents were used and in 42.8% patients bare metal stents. The stent was advanced over both wires, the target wire and the anchor wire. The anchor wire, which was passed through the proximal trailing strut of the stent helps to achieve precise stenting. The procedure was considered to be successful if stent was placed precisely covering the lesion and without stent loss or anchor wire prolapsing. Of the total 42 patients, the procedure was successful in 33, while failed in 9. Majority of failures were due to wire entanglement, which was fixed successfully in 3 cases by removing and reinserting the anchor wire. Out of other three failures, in one stent dislodgment occurred, stent could not cross the lesion in one and in another anchor wire got looped and prolapsed into target vessel.
CONCLUSION: This case series shows that the Szabo technique, in spite of some difficulties like wire entanglement, stent dislodgement and resistance during stent advancement, is a simple and feasible method for treating variety of ostial lesions precisely compared to conventional angioplasty.
Copyright © 2013 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23809379      PMCID: PMC3861314          DOI: 10.1016/j.ihj.2013.04.023

Source DB:  PubMed          Journal:  Indian Heart J        ISSN: 0019-4832


  4 in total

1.  A new technique to anchor stents for exact placement in ostial stenoses: the stent tail wire or Szabo technique.

Authors:  Morton J Kern; David Ouellette; Tony Frianeza
Journal:  Catheter Cardiovasc Interv       Date:  2006-12       Impact factor: 2.692

2.  Treatment of ostial lesions using the Szabo technique: a case series.

Authors:  Robert J Applegate; Jonathan M Davis; Joshua C Leonard
Journal:  Catheter Cardiovasc Interv       Date:  2008-11-15       Impact factor: 2.692

3.  Percutaneous coronary intervention of ostial lesions.

Authors:  Percy Jokhi; Nicholas Curzen
Journal:  EuroIntervention       Date:  2009-09       Impact factor: 6.534

4.  Two years experience of a simple technique of precise ostial coronary stenting.

Authors:  Philip Wong
Journal:  Catheter Cardiovasc Interv       Date:  2008-09-01       Impact factor: 2.692

  4 in total
  4 in total

1.  Pentafurcation of left main coronary artery.

Authors:  Paweł Tyczyński; Rafał Wolny; Hubert Łazarczyk; Paweł Litwiński; Sang Wook Kim; Adam Witkowski
Journal:  Postepy Kardiol Interwencyjnej       Date:  2016-11-17       Impact factor: 1.426

2.  Szabo 2-stent technique for coronary bifurcation lesions: procedural and short-term outcomes.

Authors:  Hongbo Yang; Juying Qian; Zheyong Huang; Junbo Ge
Journal:  BMC Cardiovasc Disord       Date:  2020-07-07       Impact factor: 2.298

3.  The Use of Bumper Wire Technique and Intravascular Ultrasound for Precise Aorto-Ostial Stenting.

Authors:  Pavan K V Reddy; Joseph Daibes; Michel Skaf; Roberto Ochoa; Tomohiro Fujisaki; Patricia Lin; Apurva Patel; Tak Kwan
Journal:  Front Cardiovasc Med       Date:  2022-07-14

4.  Potential value of guard-wire technology in the interventional treatment for ostial coronary lesions.

Authors:  Xiaoqiong Wang; Xuemei Zong; Bingqiang Li; Zhanying Han; Xinjie Duan; Ying Li; Jing Zhang; Yaohui Wang; Yaoli Wang
Journal:  BMC Cardiovasc Disord       Date:  2020-11-19       Impact factor: 2.298

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.