Literature DB >> 18412234

Two years experience of a simple technique of precise ostial coronary stenting.

Philip Wong1.   

Abstract

OBJECTIVE: To evaluate a new technique of precise ostial coronary stenting without relying solely on angiography.
BACKGROUND: Precise stent positioning at ostial coronary stenosis is difficult because angiography may not be able to profile the coronary ostium, due to vessel overlap and/or foreshortening. This problem is compounded by bobbing or to and fro movement of the stent with cardiac contraction.
METHODS: A new technique of precise ostial stenting not dependant on angiography was utilized. A guidewire in a side branch was threaded through the most proximal stent cell and the stent was advanced into the target vessel until it was stopped at the carina. The stent was deployed and the side guidewire withdrawn. All results were documented by intravascular ultrasound (IVUS).
RESULTS: From October 2005 to October 2007, 58 patients with significant ostial coronary stenosis required stenting. Seventeen patients were treated in the conventional manner and the remaining 41 patients with the new technique. The ostial locations included 8 left main, 25 left anterior descending, 3 circumflex, 1 obtuse marginal, 3 right coronary, and 1 posterior descending artery. Success, as confirmed by IVUS, was achieved in 40 patients (97.6%). Failure occurred in a right coronary ostial stenosis, which was subsequently treated by the conventional method. There were no complications.
CONCLUSION: This new technique is highly successful in cases of difficulty in stenting ostial stenosis guided solely by conventional angiography. Copyright 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2008        PMID: 18412234     DOI: 10.1002/ccd.21558

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  5 in total

1.  Causes of failure with Szabo technique - an analysis of nine cases.

Authors:  Rajendra Kumar Jain; T N C Padmanabhan; Nishad Chitnis
Journal:  Indian Heart J       Date:  2013-04-10

2.  Ostial lesion of the anterior descending coronary artery treated via Szabo technique supported by stent boost imaging: a case report.

Authors:  Guangliang Wang; Xuemei Wu
Journal:  J Cardiothorac Surg       Date:  2021-05-17       Impact factor: 1.637

3.  Szabo 2-stent technique for coronary bifurcation lesions: procedural and short-term outcomes.

Authors:  Hongbo Yang; Juying Qian; Zheyong Huang; Junbo Ge
Journal:  BMC Cardiovasc Disord       Date:  2020-07-07       Impact factor: 2.298

4.  Non-invasive characterization of complex coronary lesions.

Authors:  Madhurima Vardhan; John Gounley; S James Chen; Eric C Chi; Andrew M Kahn; Jane A Leopold; Amanda Randles
Journal:  Sci Rep       Date:  2021-04-14       Impact factor: 4.379

5.  Three-dimensional optical coherence tomography reconstruction of bifurcation stenting using the Szabo anchor-wire technique.

Authors:  Katherine Yu; Harkawal Hundal; Todd Zynda; Arnold Seto
Journal:  World J Cardiol       Date:  2017-04-26
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.