Literature DB >> 23808680

Use of robot-guided stereotactic placement of intracerebral electrodes for investigation of focal epilepsy: initial experience in the UK.

Kumar Abhinav1, Savithru Prakash, David R Sandeman.   

Abstract

We describe the operative technique and our preliminary experience with use of the Renishaw neuromate(®) stereotactic robot to implant depth electrodes for investigation of focal epilepsy in the UK. Conventional electrocorticography involving a craniotomy and implantation of grids of electrodes directly onto the brain surface is invasive and carries a high risk of major complications such as acute subdural haematoma and infection. Robot-guided depth electrodes implantation for stereotactic electroencephalography is a less invasive technique that allows accurate implantation of multiple deep brain electrodes along predefined trajectories, and has not been associated with any major surgical complications in our initial experience.

Entities:  

Mesh:

Year:  2013        PMID: 23808680     DOI: 10.3109/02688697.2013.798859

Source DB:  PubMed          Journal:  Br J Neurosurg        ISSN: 0268-8697            Impact factor:   1.596


  6 in total

Review 1.  Stereoelectroencephalography Versus Subdural Electrodes for Localization of the Epileptogenic Zone: What Is the Evidence?

Authors:  Joel S Katz; Taylor J Abel
Journal:  Neurotherapeutics       Date:  2019-01       Impact factor: 7.620

2.  Concepts and Trends n Autonomy for Robot-Assisted Surgery.

Authors:  Paolo Fiorini; Ken Y Goldberg; Yunhui Liu; Russell H Taylor
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2022-06-23       Impact factor: 14.910

Review 3.  Anesthetic considerations for stereotactic electroencephalography implantation.

Authors:  Chakrabarti Rajkalyan; Anurag Tewari; Shilpa Rao; Rafi Avitsian
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2019 Oct-Dec

4.  VarioGuide® frameless neuronavigation-guided stereoelectroencephalography in adult epilepsy patients: technique, accuracy and clinical experience.

Authors:  Barbara Ladisich; Lukas Machegger; Alexander Romagna; Herbert Krainz; Jürgen Steinbacher; Markus Leitinger; Gudrun Kalss; Niklas Thon; Eugen Trinka; Peter A Winkler; Christoph Schwartz
Journal:  Acta Neurochir (Wien)       Date:  2021-02-13       Impact factor: 2.216

5.  A novel method for implementation of frameless StereoEEG in epilepsy surgery.

Authors:  Mark Nowell; Roman Rodionov; Beate Diehl; Tim Wehner; Gergely Zombori; Jane Kinghorn; Sebastien Ourselin; John Duncan; Anna Miserocchi; Andrew McEvoy
Journal:  Neurosurgery       Date:  2014-12       Impact factor: 4.654

6.  Neuronavigation-guided Frameless Stereoelectroencephalography (SEEG).

Authors:  Ayataka Fujimoto; Tohru Okanishi; Sotaro Kanai; Keishiro Sato; Mitsuyo Nishimura; Hideo Enoki
Journal:  Neurol Med Chir (Tokyo)       Date:  2017-08-01       Impact factor: 1.742

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.