Literature DB >> 22025731

Spatiotemporal monitoring of high-intensity focused ultrasound therapy with passive acoustic mapping.

Carl R Jensen1, Robert W Ritchie, Miklós Gyöngy, James R T Collin, Tom Leslie, Constantin-C Coussios.   

Abstract

PURPOSE: To demonstrate feasibility of monitoring high-intensity focused ultrasound (HIFU) treatment with passive acoustic mapping of broadband and harmonic emissions reconstructed from filtered-channel radiofrequency data in ex vivo bovine tissue.
MATERIALS AND METHODS: Both passive acoustic emissions and B-mode images were recorded with a diagnostic ultrasound machine during 180 HIFU exposures of five freshly excised, degassed bovine livers. Tissue was exposed to peak rarefactional pressures between 3.6 and 8.0 MPa for 2, 5, or 10 seconds. The B-mode images were analyzed for hyperechoic activity, and threshold levels were determined for the harmonic (1.17 mJ) and broadband (0.0137 mJ) components of the passively reconstructed source energy to predict tissue ablation. Both imaging methods were compared with tissue lesions after exposure to determine their spatial accuracy and their capability to help predict presence of ablated tissue. Performance of both methods as detectors was compared (matched-pair test design).
RESULTS: Passive mapping successfully aided prediction of the presence of tissue ablation more often than did conventional hyperechoic images (49 of 58 [84%] vs 31 of 58 [53%], P < .001). At 5.4-6.3-MPa exposures, sensitivity, specificity, negative predictive value, and positive predictive value of the two methods, respectively, were 15 of 20 versus five of 21 (P = .006), eight of nine versus eight of nine (P = .72), 15 of 16 versus five of six (P = .53), and eight of 13 versus eight of 24 (P = .011). Across HIFU exposure amplitude ranges, passive acoustic mapping also aided correct prediction of the visually detected location of ablation following tissue sectioning in 42 of 45 exposures for which the harmonic and broadband threshold levels for tissue ablation were exceeded. Early cavitation activity indicated the focal position within the tissue before irreversible tissue damage occurred.
CONCLUSION: Passive acoustic mapping significantly outperformed the conventional hyperecho technique as an ultrasound-based HIFU monitoring method, as both a detector of lesion occurrence and a method of mapping the position of ablated tissue.

Entities:  

Mesh:

Year:  2011        PMID: 22025731     DOI: 10.1148/radiol.11110670

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  50 in total

Review 1.  Ultrasound enhanced drug delivery to the brain and central nervous system.

Authors:  Meaghan A O'Reilly; Kullervo Hynynen
Journal:  Int J Hyperthermia       Date:  2012       Impact factor: 3.914

2.  Passive imaging with pulsed ultrasound insonations.

Authors:  Kevin J Haworth; T Douglas Mast; Kirthi Radhakrishnan; Mark T Burgess; Jonathan A Kopechek; Shao-Ling Huang; David D McPherson; Christy K Holland
Journal:  J Acoust Soc Am       Date:  2012-07       Impact factor: 1.840

Review 3.  High-Intensity Focused Ultrasound: Current Status for Image-Guided Therapy.

Authors:  Alexander Copelan; Jason Hartman; Monzer Chehab; Aradhana M Venkatesan
Journal:  Semin Intervent Radiol       Date:  2015-12       Impact factor: 1.513

Review 4.  Therapeutic potential of ultrasound microbubbles in gastrointestinal oncology: recent advances and future prospects.

Authors:  Tatiana D Khokhlova; Yasser Haider; Joo Ha Hwang
Journal:  Therap Adv Gastroenterol       Date:  2015-11       Impact factor: 4.409

5.  Integrated ultrasound and magnetic resonance imaging for simultaneous temperature and cavitation monitoring during focused ultrasound therapies.

Authors:  Costas D Arvanitis; Nathan McDannold
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

6.  A super-resolution ultrasound method for brain vascular mapping.

Authors:  Meaghan A O'Reilly; Kullervo Hynynen
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

7.  Three-dimensional transcranial ultrasound imaging of microbubble clouds using a sparse hemispherical array.

Authors:  Meaghan A O'Reilly; Ryan M Jones; Kullervo Hynynen
Journal:  IEEE Trans Biomed Eng       Date:  2014-04       Impact factor: 4.538

8.  A new active cavitation mapping technique for pulsed HIFU applications--bubble Doppler.

Authors:  Tong Li; Tatiana D Khokhlova; Oleg A Sapozhnikov; Matthew O'Donnell; Joo Ha Hwang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-10       Impact factor: 2.725

9.  Spatial specificity and sensitivity of passive cavitation imaging for monitoring high-intensity focused ultrasound thermal ablation in ex vivo bovine liver.

Authors:  Kevin Haworth; Vasant A Salgaonkar; Nicholas M Corregan; Christy K Holland; T D Mast
Journal:  Proc Meet Acoust       Date:  2013-06-02

10.  Multi-parametric monitoring and assessment of high-intensity focused ultrasound (HIFU) boiling by harmonic motion imaging for focused ultrasound (HMIFU): an ex vivo feasibility study.

Authors:  Gary Y Hou; Fabrice Marquet; Shutao Wang; Elisa E Konofagou
Journal:  Phys Med Biol       Date:  2014-02-20       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.