Novel 3-dimensional motion analysis method for measuring the lumbar spine range of motion: repeatability and reliability compared with an electrogoniometer.

Michio Tojima1, Naoshi Ogata, Arito Yozu, Masahiko Sumitani, Nobuhiko Haga.   

Abstract

STUDY
DESIGN: Repeatability and reliability for measuring methods for real-time lumbar range of motion.
OBJECTIVE: We established a novel set of marker positions for 3-dimensional motion analysis (VICON system) to determine lumbar spine range of motion (LROM) and lumbar motion precisely; we compared the repeatability and reliability of VICON system with those of an electrogoniometer. SUMMARY OF BACKGROUND DATA: The assessment of the LROM using x-ray is still one of the most precise methods, despite the radiation exposure. To avoid this, alternative methods, such as the VICON system and electrogoniometer, have been widely used. No study has reported the repeatability and reliability of LROM measurements using a VICON system and electrogoniometer.
METHODS: The VICON system and electrogoniometer measured LROM and lumbar motion in 7 healthy males during 7 days. Differences between both systems were analyzed using Bland-Altman plots. Repeatability and reliability of the LROM measurements was assessed using coefficients of multiple correlations and intraclass correlation coefficients, respectively. Standard error of measurement was calculated to quantify the systematic error in LROM measurements.
RESULTS: The mean maximum LROM values using the VICON system/electrogoniometer were 42°/52° for flexion, 17°/24° for extension, 16°/16° for lateral bending, and 8°/2° for axial rotation, respectively. Between VICON system and the electrogoniometer, Bland-Altman plots revealed no discrepancies in LROM values except for flexion.Coefficients of multiple correlations for LROM showed excellent repeatability. LROM measurements with VICON system showed excellent reliability for flexion and extension and fair-to-good reliability for other motions. LROM measurements with the electrogoniometer showed excellent reliability for flexion and fair-to-good reliability for other motions. Except for axial rotation, maximum intraclass correlation coefficients using VICON system were more reliable than the electrogoniometer for measuring lumbar motion.
CONCLUSION: VICON system with our novel marker set allows practical and reliable longitudinal assessment of dynamic LROM. LEVEL OF EVIDENCE: N/A.

Entities:  

Mesh:

Year:  2013        PMID: 23797505     DOI: 10.1097/BRS.0b013e3182a0dbc5

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  11 in total

1.  Between-session reliability of opto-electronic motion capture in measuring sagittal posture and 3-D ranges of motion of the thoracolumbar spine.

Authors:  Seyed Javad Mousavi; Rebecca Tromp; Matthew C Swann; Andrew P White; Dennis E Anderson
Journal:  J Biomech       Date:  2018-09-03       Impact factor: 2.712

2.  Neck range of motion measurements using a new three-dimensional motion analysis system: validity and repeatability.

Authors:  Haruhi Inokuchi; Michio Tojima; Hiroshi Mano; Yuki Ishikawa; Naoshi Ogata; Nobuhiko Haga
Journal:  Eur Spine J       Date:  2015-04-07       Impact factor: 3.134

3.  Kinesiophobia modulates lumbar movements in people with chronic low back pain: a kinematic analysis of lumbar bending and returning movement.

Authors:  Michihiro Osumi; Masahiko Sumitani; Yuko Otake; Tomohiko Nishigami; Akira Mibu; Yuki Nishi; Ryota Imai; Gosuke Sato; Yusuke Nagakura; Shu Morioka
Journal:  Eur Spine J       Date:  2019-05-21       Impact factor: 3.134

4.  Factors Associated with Ball Velocity and Low Back Pain During Kicking in Adolescent Soccer Players.

Authors:  Michio Tojima; Seira Takei; Suguru Torii
Journal:  Open Access J Sports Med       Date:  2020-09-07

5.  Immediate effects of muscle energy technique and stabilization exercise in patients with chronic low back pain with suspected facet joint origin: A pilot study.

Authors:  Wahyuddin Wahyuddin; Mantana Vongsirinavarat; Keerin Mekhora; Sunee Bovonsunthonchai; Rachaneewan Adisaipoapun
Journal:  Hong Kong Physiother J       Date:  2020-03-20

6.  COMPARISON OF LUMBOPELVIC RHYTHM AMONG ADOLESCENT SOCCER PLAYERS WITH AND WITHOUT LOW BACK PAIN.

Authors:  Michio Tojima; Suguru Torii
Journal:  Int J Sports Phys Ther       Date:  2018-04

7.  The effect of proficiency level on measurement error of range of motion.

Authors:  Kazunori Akizuki; Kazuto Yamaguchi; Yoshiyuki Morita; Yukari Ohashi
Journal:  J Phys Ther Sci       Date:  2016-09-29

8.  Three-dimensional motion analysis of lumbopelvic rhythm during lateral trunk bending.

Authors:  Michio Tojima; Naoshi Ogata; Haruhi Inokuchi; Nobuhiko Haga
Journal:  J Phys Ther Sci       Date:  2016-08-31

9.  Three-Dimensional Motion Analysis of Lumbopelvic Rhythm During Trunk Extension.

Authors:  Michio Tojima; Naoshi Ogata; Yasuo Nakahara; Nobuhiko Haga
Journal:  J Hum Kinet       Date:  2016-04-13       Impact factor: 2.193

10.  Extrinsic feedback from a feedback device promotes the learning of range of motion measurements.

Authors:  Kazunori Akizuki; Kaho Mitamura; Ryohei Yamamoto; Kazuto Yamaguchi; Yukari Ohashi
Journal:  J Phys Ther Sci       Date:  2020-02-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.