Short and longer term repeatability of ballistocardiography in a sitting position with EMFi sensor.

Jarmo Alametsä1, Ari Palomäki, Jari Viik.   

Abstract

Short and long-term alterations of ballistocardiographic parameters (BCG) were studied in a sitting position using Electromechanical Film (EMFi) sensors. Several physiological parameters were recorded from 48 men of middle age in consecutive recordings and after a 2-week interval. The duration and amplitudes of the signal components were studied. The repeatability index R, the Pearson correlation, and Bland-Altman (BA) repeatability methods were used to determine how repeatable the studied signals are. In consecutive and during 2 week recordings, the Pearson correlation rates for BCG systolic component values (from 0.88/0.83 (T(RJ)) to 0.97/0.78 (A(IJ)), PWV values for the left 0.97/0.67 and right ankle 0.98/0.76) were detected indicating excellent repeatability during consecutive recordings. Respectively BA T(RJ) was -0.002 ± 0.028/-0.004 ± 0.030. Corresponding R values were T(RJ) 0.90/0.82 and right ankle PWV 0.98/0.81. Quite modest blood pressure R values were obtained between 2 week recordings (systolic 0.63, diastolic 0.75, and heart rate 0.59). BCG and PWV measured with EMFi sensors are highly repeatable in consecutive recordings. In longer time interval recordings, BCG is influenced by hemodynamic instability, but in spite of this the reproducibility of the main parameters of the BCG and PWV were better than measured heart rate and blood pressure values.

Entities:  

Mesh:

Year:  2011        PMID: 21336678     DOI: 10.1007/s11517-011-0746-y

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  18 in total

1.  Design of an ultra low frequency force ballistocardiograph on the principle of the horizontal pendulum.

Authors:  T J REEVES; W B JONES; L L HEFNER
Journal:  Circulation       Date:  1957-07       Impact factor: 29.690

2.  Dynamic comparison of current ballistocardiographic methods. I. Artifacts in the dynamically simple ballistocardiographic methods.

Authors:  S A TALBOT; W K HARRISON
Journal:  Circulation       Date:  1955-10       Impact factor: 29.690

3.  The ballistocardiogram in the diagnosis of coronary arterial disease.

Authors:  E G WADE; R M FULTON; J MACKINNON
Journal:  Br Heart J       Date:  1956-01

Review 4.  Contour analysis of the photoplethysmographic pulse measured at the finger.

Authors:  Sandrine C Millasseau; James M Ritter; Kenji Takazawa; Philip J Chowienczyk
Journal:  J Hypertens       Date:  2006-08       Impact factor: 4.844

5.  THE CONSTRUCTION OF NORMAL STANDARDS FOR CARDIAC OUTPUT IN MAN.

Authors:  J M Tanner
Journal:  J Clin Invest       Date:  1949-05       Impact factor: 14.808

6.  On certain abnormal ballistic complexes; their relationships to other mechanical and electrical events of the cardiac cycle.

Authors:  P T KUO; T G SCHNABEL; C F KAY
Journal:  Circulation       Date:  1952-07       Impact factor: 29.690

7.  Home blood pressure has a stronger association with arterial stiffness than clinic blood pressure: the Finn-Home Study.

Authors:  Teemu J Niiranen; Antti M Jula; Ilkka M Kantola; Mika Kähönen; Antti Reunanen
Journal:  Blood Press Monit       Date:  2009-10       Impact factor: 1.444

Review 8.  A procedure for evaluation of non-invasive blood pressure simulators.

Authors:  Gregor Gersak; Ales Zemva; Janko Drnovsek
Journal:  Med Biol Eng Comput       Date:  2009-10-13       Impact factor: 2.602

9.  A simple ballistocardiographic measure (IJ/HI amplitude ratio) in relation to electrocardiographic evidence of ischaemic heart disease.

Authors:  U de Faire; T Theorell
Journal:  Scand J Clin Lab Invest       Date:  1979-09       Impact factor: 1.713

10.  Unreliable oscillometric blood pressure measurement: prevalence, repeatability and characteristics of the phenomenon.

Authors:  G S Stergiou; P Lourida; D Tzamouranis; N M Baibas
Journal:  J Hum Hypertens       Date:  2009-03-26       Impact factor: 3.012

View more
  4 in total

1.  Simplified detection of myocardial ischemia by seismocardiography. Differentiation between causes of altered myocardial function.

Authors:  M Becker; A B Roehl; U Siekmann; A Koch; M de la Fuente; R Roissant; K Radermacher; N Marx; M Hein
Journal:  Herz       Date:  2013-06-23       Impact factor: 1.443

2.  A Ballistographic Approach for Continuous and Non-Obtrusive Monitoring of Movement in Neonates.

Authors:  Rohan Joshi; Bart L Bierling; Xi Long; Janna Weijers; Loe Feijs; Carola Van Pul; Peter Andriessen
Journal:  IEEE J Transl Eng Health Med       Date:  2018-10-12       Impact factor: 3.316

3.  Kinocardiography Derived from Ballistocardiography and Seismocardiography Shows High Repeatability in Healthy Subjects.

Authors:  Amin Hossein; Jérémy Rabineau; Damien Gorlier; Jose Ignacio Juarez Del Rio; Philippe van de Borne; Pierre-François Migeotte; Antoine Nonclercq
Journal:  Sensors (Basel)       Date:  2021-01-26       Impact factor: 3.576

4.  Efficacy of Non-contact BallistocardiographySystem to Determine Heart Rate Variability.

Authors:  Gaurav Parchani; Gulshan Kumar; Raghavendra Rao; Kaviraja Udupa; Vibhor Saran
Journal:  Ann Neurosci       Date:  2022-02-02
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.