Literature DB >> 23788604

Dual-energy 4-phase CT scan in primary hyperparathyroidism.

D Lau, H Yang, P L Kei.   

Abstract

Entities:  

Mesh:

Year:  2013        PMID: 23788604      PMCID: PMC8051454          DOI: 10.3174/ajnr.A3657

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


× No keyword cloud information.
  5 in total

1.  Parathyroid lesions: characterization with dual-phase arterial and venous enhanced CT of the neck.

Authors:  A R Gafton; C M Glastonbury; J D Eastwood; J K Hoang
Journal:  AJNR Am J Neuroradiol       Date:  2012-01-12       Impact factor: 3.825

2.  Image quality and radiation dose of dual-energy CT of the head and neck compared with a standard 120-kVp acquisition.

Authors:  A M Tawfik; J M Kerl; A A Razek; R W Bauer; N E Nour-Eldin; T J Vogl; M G Mack
Journal:  AJNR Am J Neuroradiol       Date:  2011-09-08       Impact factor: 3.825

3.  Diagnostic accuracy of 4D-CT for parathyroid adenomas and hyperplasia.

Authors:  J L Chazen; A Gupta; A Dunning; C D Phillips
Journal:  AJNR Am J Neuroradiol       Date:  2011-12-01       Impact factor: 3.825

4.  Parathyroid localization with modified 4D-computed tomography and ultrasonography for patients with primary hyperparathyroidism.

Authors:  David I Kutler; Rachel Moquete; Elias Kazam; William I Kuhel
Journal:  Laryngoscope       Date:  2011-05-06       Impact factor: 3.325

5.  Accuracy of four-dimensional CT for the localization of abnormal parathyroid glands in patients with primary hyperparathyroidism.

Authors:  George J Hunter; Dawid Schellingerhout; Thinh H Vu; Nancy D Perrier; Leena M Hamberg
Journal:  Radiology       Date:  2012-07-12       Impact factor: 11.105

  5 in total
  3 in total

Review 1.  Clinical applications of dual-energy CT in head and neck imaging.

Authors:  Daniel Thomas Ginat; Michael Mayich; Laleh Daftari-Besheli; Rajiv Gupta
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-12-04       Impact factor: 2.503

2.  Renal Adiposity Does not Preclude Quantitative Assessment of Renal Function Using Dual-Energy Multidetector CT in Mildly Obese Human Subjects.

Authors:  Christopher M Ferguson; Alfonso Eirin; Gregory J Michalak; Ahmad F Hedayat; Abdelrhman M Abumoawad; Ahmed Saad; Xiangyang Zhu; Stephen C Textor; Cynthia H McCollough; Lilach O Lerman
Journal:  Acad Radiol       Date:  2019-01-14       Impact factor: 3.173

Review 3.  Dual-Energy CT in Head and Neck Imaging.

Authors:  Elise D Roele; Veronique C M L Timmer; Lauretta A A Vaassen; Anna M J L van Kroonenburgh; A A Postma
Journal:  Curr Radiol Rep       Date:  2017-03-29
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.