Literature DB >> 21557243

Parathyroid localization with modified 4D-computed tomography and ultrasonography for patients with primary hyperparathyroidism.

David I Kutler1, Rachel Moquete, Elias Kazam, William I Kuhel.   

Abstract

OBJECTIVES: In this article, we report our decade-long experience in using modified 4D-computed tomography in combination with ultrasonography (Mod 4D-CT/US) to localize abnormal parathyroid glands in patients with primary hyperparathyroidism. STUDY
DESIGN: Retrospective medical record review at a university-based academic medical center.
METHODS: Patients with primary hyperparathyroidism who underwent a Mod 4D-CT/US and parathyroidectomy between January 1998 and May 2009 were included in the study. Results from preoperative localization studies were compared with operative findings, pathologic data, and biochemical measurements to assess the sensitivity and specificity as well as the positive and negative predictive values of Mod 4D-CT/US.
RESULTS: Mod 4D-CT/US demonstrated 94% sensitivity and 96% specificity when these imaging studies were used to lateralize the hyperfunctioning parathyroid glands to one side of the neck. In regard to localizing abnormal parathyroid glands to a specific quadrant of the neck (i.e., right-left; superior-inferior), the sensitivity and specificity of Mod 4D-CT/US was 82% and 93%, respectively. Mod 4D-CT/US had a 92% positive predictive value for single-gland disease and 75% for multigland disease. The negative predictive value for single and multigland disease (MGD) were 73% and 92%, respectively.
CONCLUSIONS: Mod 4D-CT/US provides excellent sensitivity and specificity in terms of localizing abnormal parathyroid glands to the correct side and quadrant in patients with primary hyperparathyroidism, and it correctly identifies many patients with MGD.
Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21557243     DOI: 10.1002/lary.21783

Source DB:  PubMed          Journal:  Laryngoscope        ISSN: 0023-852X            Impact factor:   3.325


  20 in total

1.  Parathyroid lesions: characterization with dual-phase arterial and venous enhanced CT of the neck.

Authors:  A R Gafton; C M Glastonbury; J D Eastwood; J K Hoang
Journal:  AJNR Am J Neuroradiol       Date:  2012-01-12       Impact factor: 3.825

2.  Dynamic parathyroid CT: are 2 phases sufficient?

Authors:  A R Sepahdari; A Harari
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-22       Impact factor: 3.825

3.  Effect of tumor volume on the enhancement pattern of parathyroid adenoma on parathyroid four-dimensional CT.

Authors:  Eun Kyoung Lee; Tae Jin Yun; Ji-Hoon Kim; Kyu Eun Lee; Su-Jin Kim; Jae-Kyung Won; Koung Mi Kang; Seung Hong Choi; Chul-Ho Sohn
Journal:  Neuroradiology       Date:  2016-02-05       Impact factor: 2.804

4.  Preoperative ¹¹C-methionine PET/CT enables focused parathyroidectomy in MIBI-SPECT negative parathyroid adenoma.

Authors:  Christina Lenschow; Peter Gassmann; Christian Wenning; Norbert Senninger; Mario Colombo-Benkmann
Journal:  World J Surg       Date:  2015-07       Impact factor: 3.352

5.  4D-CT for preoperative localization of abnormal parathyroid glands in patients with hyperparathyroidism: accuracy and ability to stratify patients by unilateral versus bilateral disease in surgery-naive and re-exploration patients.

Authors:  H R Kelly; L M Hamberg; G J Hunter
Journal:  AJNR Am J Neuroradiol       Date:  2013-07-18       Impact factor: 3.825

6.  Dual-energy 4-phase CT scan in primary hyperparathyroidism.

Authors:  D Lau; H Yang; P L Kei
Journal:  AJNR Am J Neuroradiol       Date:  2013-06-20       Impact factor: 3.825

7.  MR appearance of parathyroid adenomas at 3 T in patients with primary hyperparathyroidism: what radiologists need to know for pre-operative localization.

Authors:  B Sacconi; R Argirò; Daniele Diacinti; A Iannarelli; M Bezzi; C Cipriani; D Pisani; V Cipolla; C De Felice; S Minisola; C Catalano
Journal:  Eur Radiol       Date:  2015-05-31       Impact factor: 5.315

8.  Multiparametric ultrasonography and ultrasound elastography in the differentiation of parathyroid lesions from ectopic thyroid lesions or lymphadenopathies.

Authors:  Andrea M Isidori; Vito Cantisani; Elisa Giannetta; Daniele Diacinti; Emanuele David; Valerio Forte; Daniela Elia; Corrado De Vito; Emilia Sbardella; Daniele Gianfrilli; Francesco Monteleone; Jessica Pepe; Salvatore Minisola; Giorgio Ascenti; Vito D'Andrea; Carlo Catalano; Ferdinando D'Ambrosio
Journal:  Endocrine       Date:  2016-10-05       Impact factor: 3.633

9.  Dynamic CT for parathyroid disease: are multiple phases necessary?

Authors:  P Raghavan; C R Durst; D A Ornan; S Mukherjee; M Wintermark; J T Patrie; W Xin; A L Shada; J B Hanks; P W Smith
Journal:  AJNR Am J Neuroradiol       Date:  2014-06-05       Impact factor: 3.825

10.  Clinical efficacy of 2-phase versus 4-phase computed tomography for localization in primary hyperparathyroidism.

Authors:  Adriana G Ramirez; Amber L Shada; Allison N Martin; Prashant Raghavan; Christopher R Durst; Sugoto Mukherjee; John R Gaughen; David A Ornan; John B Hanks; Philip W Smith
Journal:  Surgery       Date:  2016-06-11       Impact factor: 3.982

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.