Literature DB >> 23783214

Comparison of fixed and mobile-bearing total knee arthroplasty at a mean follow-up of 116 months.

Alessandro Bistolfi1, Giuseppe Massazza, Gwo-Chin Lee, Davide Deledda, Paola Berchialla, Maurizio Crova.   

Abstract

BACKGROUND: The superiority of mobile-bearing total knee arthroplasty implants over fixed-bearing implants, or vice versa, is still debated.
METHODS: A series of patients with similar clinical and radiographic characteristics were treated consecutively with 100 fixed-bearing followed by 100 rotating-platform implants. Patients underwent prospective clinical and radiographic evaluation.
RESULTS: The mean duration of follow-up was 116 months (range, sixty-one to 144 months). Clinical, radiographic, and implant survival outcomes were compared. No significant differences between the mobile-bearing and fixed-bearing groups were found with respect to the clinical outcome or cumulative implant survival at the time of the latest follow-up. Three of the fixed-bearing implants and one of the rotating-platform implants had required revision surgery.
CONCLUSIONS: No differences between mobile-bearing and fixed-bearing designs were demonstrated at a mean of 116 months of follow-up.

Entities:  

Mesh:

Year:  2013        PMID: 23783214     DOI: 10.2106/JBJS.L.00327

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  11 in total

1.  International comparative evaluation of knee replacement with fixed or mobile non-posterior-stabilized implants.

Authors:  Robert Namba; Stephen Graves; Otto Robertsson; Ove Furnes; Susanna Stea; Lluis Puig-Verdié; Daniel Hoeffel; Guy Cafri; Elizabeth Paxton; Art Sedrakyan
Journal:  J Bone Joint Surg Am       Date:  2014-12-17       Impact factor: 5.284

2.  Treatment of knee osteoarthritis by intra-articular injection of concentrated autologous adipose tissue: a twenty four month follow-up study.

Authors:  Alessandro Bistolfi; Ilaria Roato; Giulia Fornelli; Luigi Sabatini; Alessandro Massè; Riccardo Ferracini
Journal:  Int Orthop       Date:  2021-01-04       Impact factor: 3.075

3.  New total knee arthroplasty designs: do young patients notice?

Authors:  Ryan M Nunley; Denis Nam; Keith R Berend; Adolph V Lombardi; Douglas A Dennis; Craig J Della Valle; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2015-01       Impact factor: 4.176

4.  NexGen® LPS mobile bearing total knee arthroplasty: 10-year results.

Authors:  Alessandro Bistolfi; Gwo-Chin Lee; Davide Deledda; Federica Rosso; Paola Berchialla; Maurizio Crova; Giuseppe Massazza
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-04-30       Impact factor: 4.342

Review 5.  Cruciate retaining and cruciate substituting ultra-congruent insert.

Authors:  Luca Mazzucchelli; Davide Deledda; Federica Rosso; Nicola Ratto; Matteo Bruzzone; Davide Edoardo Bonasia; Roberto Rossi
Journal:  Ann Transl Med       Date:  2016-01

6.  Long-term follow-up of a non-randomised prospective cohort of one hundred and ninety two total knee arthroplasties using the NexGen implant.

Authors:  Alfredo Schiavone Panni; Franceso Falez; Rocco D'Apolito; Katia Corona; Carlo Perisano; Michele Vasso
Journal:  Int Orthop       Date:  2017-03-22       Impact factor: 3.075

7.  Mobile-bearing prosthesis and intraoperative gap balancing are not predictors of superior knee flexion: a prospective randomized study.

Authors:  Yukihide Minoda; Hiroyoshi Iwaki; Mitsuhiko Ikebuchi; Taku Yoshida; Shigekazu Mizokawa; Maki Itokazu; Hiroaki Nakamura
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-01-17       Impact factor: 4.342

8.  Acute, recurrent total knee dislocation: Polyethylene dislocation and malreduction.

Authors:  Samuel F Thompson; Blake E Peterson; Ajay Aggarwal
Journal:  Arthroplast Today       Date:  2015-03-20

9.  No difference in clinical outcome, pain, and range of motion between fixed and mobile bearing Attune total knee arthroplasty: a prospective single-center trial.

Authors:  Paul Ruckenstuhl; Fabio Revelant; Georg Hauer; Gerwin A Bernhardt; Lukas Leitner; Gerald Gruber; Andreas Leithner; Patrick Sadoghi
Journal:  BMC Musculoskelet Disord       Date:  2022-05-02       Impact factor: 2.562

10.  Mobile-bearing insert used with total knee arthroplasty does not rotate on the tibial tray during a squatting activity: a cross-sectional study.

Authors:  Kenji Hoshi; Goro Watanabe; Yasuo Kurose; Ryuji Tanaka; Jiro Fujii; Kazuyoshi Gamada
Journal:  J Orthop Surg Res       Date:  2020-03-20       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.