New total knee arthroplasty designs: do young patients notice?

Ryan M Nunley1, Denis Nam, Keith R Berend, Adolph V Lombardi, Douglas A Dennis, Craig J Della Valle, Robert L Barrack.   

Abstract

BACKGROUND: Although the volume of total knee arthroplasties (TKAs) performed in the United States continues to increase, recent reports have shown the percentage of patients who remain "unsatisfied" is as high as 15% to 30%. Recently, several newer implant designs have been developed to potentially improve patient outcomes. QUESTIONS/PURPOSES: The purpose of this study was to determine the impact of high-flex, gender-specific, and rotating-platform TKA designs on patient satisfaction and functional outcomes.
METHODS: A four-center study was designed to quantify the degree of residual symptoms and functional deficits in patients undergoing TKA with newer implant designs compared with a 10-year-old, cruciate-retaining (CR) TKA system introduced in 2003. Each contributing surgeon was fellowship-trained and specialized in joint replacement surgery. Only patients younger than 60 years old were included. Data were collected by an independent, third-party survey center blinded to the implant type, who administered questionnaires about patient satisfaction, residual symptoms, function, and pre- and postoperative activity levels using previously published survey instruments. Two hundred thirty-seven CR, 137 rotating-platform, 88 gender-specific, and 65 high-flex TKAs were included in the analysis. Differences in baseline demographic variables were accounted for using multiple logistic regression statistical analyses.
RESULTS: Patients who received certain newer designs reported more residual symptoms (grinding, popping, and clicking) in the 30 days before survey administration than the group receiving a 10-year-old CR design (CR, 24% [57 of 237 patients] versus gender-specific, 36% [32 of 88 patients]; odds ratio [OR], 2.1; 95% confidence interval [CI], 1.1-3.8; p=0.03; and rotating-platform, 43% [59 of 137 patients]; OR, 2.2; 95% CI, 1.3-3.7; p<0.001). They also reported more functional problems, including getting in and out of a chair (CR, 19% [46 of 237 patients] versus gender-specific, 37% [32 of 88 patients]; OR, 1.0; 95% CI, 1.1-3.5; p=0.001). Patients with newer TKA designs did not demonstrate any improvements in function or patient satisfaction versus those who received the 10-year-old CR design.
CONCLUSIONS: When interviewed by an independent, blinded third party, the use of newer implant designs did not improve patient satisfaction and the presence of residual symptoms when compared with patients who received the 10-year-old CR design. Future studies should prospectively determine whether the purported benefits of newer implant designs improve patient-perceived outcomes. LEVEL OF EVIDENCE: Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2015        PMID: 24903823      PMCID: PMC4390919          DOI: 10.1007/s11999-014-3713-8

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  43 in total

1.  Kneeling kinematics after total knee arthroplasty: anterior-posterior contact position of a standard and a high-flex tibial insert design.

Authors:  Kathryn M Coughlin; Stephen J Incavo; Robert R Doohen; Kazuyoshi Gamada; Scott Banks; Bruce D Beynnon
Journal:  J Arthroplasty       Date:  2007-02       Impact factor: 4.757

2.  Three-dimensional tibiofemoral kinematics during deep flexion kneeling in a mobile-bearing total knee arthroplasty.

Authors:  Eiichi Nakamura; S A Banks; Azusa Tanaka; Akira Sei; Hiroshi Mizuta
Journal:  J Arthroplasty       Date:  2008-09-26       Impact factor: 4.757

3.  The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement.

Authors:  D L Bartel; V L Bicknell; T M Wright
Journal:  J Bone Joint Surg Am       Date:  1986-09       Impact factor: 5.284

4.  The patient-specific functional scale: psychometrics, clinimetrics, and application as a clinical outcome measure.

Authors:  Katyana Kowalchuk Horn; Sophie Jennings; Gillian Richardson; Ditte Van Vliet; Cheryl Hefford; J Haxby Abbott
Journal:  J Orthop Sports Phys Ther       Date:  2011-10-25       Impact factor: 4.751

5.  Range of motion in total knee replacement.

Authors:  Y S Anouchi; M McShane; F Kelly; J Elting; J Stiehl
Journal:  Clin Orthop Relat Res       Date:  1996-10       Impact factor: 4.176

6.  Predictors of moderate-severe functional limitation 2 and 5 years after revision total knee arthroplasty.

Authors:  Jasvinder A Singh; Megan M O'Byrne; W Scott Harmsen; David G Lewallen
Journal:  J Arthroplasty       Date:  2010-10       Impact factor: 4.757

7.  Assessing activity in joint replacement patients.

Authors:  C A Zahiri; T P Schmalzried; E S Szuszczewicz; H C Amstutz
Journal:  J Arthroplasty       Date:  1998-12       Impact factor: 4.757

8.  Which is the best activity rating scale for patients undergoing total joint arthroplasty?

Authors:  Florian D Naal; Franco M Impellizzeri; Michael Leunig
Journal:  Clin Orthop Relat Res       Date:  2008-06-28       Impact factor: 4.176

9.  Do patients return to work after total knee arthroplasty?

Authors:  Adolph V Lombardi; Ryan M Nunley; Keith R Berend; Erin L Ruh; John C Clohisy; William G Hamilton; Craig J Della Valle; Javad Parvizi; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

10.  Prevalence of cholesterol screening and high blood cholesterol among adults--United States, 2005, 2007, and 2009.

Authors: 
Journal:  MMWR Morb Mortal Wkly Rep       Date:  2012-09-07       Impact factor: 17.586

View more
  11 in total

Review 1.  Larger range of motion and increased return to activity, but higher revision rates following unicompartmental versus total knee arthroplasty in patients under 65: a systematic review.

Authors:  Laura J Kleeblad; Jelle P van der List; Hendrik A Zuiderbaan; Andrew D Pearle
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-11-28       Impact factor: 4.342

2.  Editorial: How Does CORR ® Evaluate Survey Studies?

Authors:  Matthew B Dobbs; Mark C Gebhardt; Terence J Gioe; Paul A Manner; Raphaël Porcher; Clare M Rimnac; Montri D Wongworawat; Seth S Leopold
Journal:  Clin Orthop Relat Res       Date:  2017-06-29       Impact factor: 4.176

Review 3.  Intraoperative load-sensing drives the level of constraint in primary total knee arthroplasty: Surgical technique and review of the literature.

Authors:  Salvatore Risitano; Brian Karamian; Pier Francesco Indelli
Journal:  J Clin Orthop Trauma       Date:  2017-06-02

4.  Short term patient outcomes after total knee arthroplasty: Does the implant matter?

Authors:  Ilda B Molloy; Benjamin J Keeney; Michael B Sparks; Nicholas G Paddock; Karl M Koenig; Wayne E Moschetti; David S Jevsevar
Journal:  Knee       Date:  2019-03-23       Impact factor: 2.199

5.  Personalised high tibial osteotomy has mechanical safety equivalent to generic device in a case-control in silico clinical trial.

Authors:  Alisdair R MacLeod; Nicholas Peckham; Gil Serrancolí; Ines Rombach; Patrick Hourigan; Vipul I Mandalia; Andrew D Toms; Benjamin J Fregly; Harinderjit S Gill
Journal:  Commun Med (Lond)       Date:  2021-06-30

6.  What Is the Frequency of Noise Generation in Modern Knee Arthroplasty and Is It Associated With Residual Symptoms?

Authors:  Denis Nam; Toby Barrack; Ryan M Nunley; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2017-01       Impact factor: 4.176

7.  Does Knee Prosthesis Survivorship Improve When Implant Designs Change? Findings from the Australian Orthopaedic Association National Joint Replacement Registry.

Authors:  Peter L Lewis; Stephen E Graves; Richard N de Steiger; David G Campbell; Yi Peng; Alesha Hatton; Michelle Lorimer
Journal:  Clin Orthop Relat Res       Date:  2020-06       Impact factor: 4.755

8.  The ratio of patient body mass index to age: a cost-effective implant selection guideline for total knee arthroplasty.

Authors:  Feroz A Osmani; Nicholas Bolz; Khalid Odeh; Craig Bearison; Ran Schwarzkopf; Richard Iorio
Journal:  Arthroplast Today       Date:  2017-10-21

9.  Does knee awareness differ between different knee arthroplasty prostheses? A matched, case-control, cross-sectional study.

Authors:  Morten G Thomsen; Roshan Latifi; Thomas Kallemose; Henrik Husted; Anders Troelsen
Journal:  BMC Musculoskelet Disord       Date:  2016-04-01       Impact factor: 2.362

10.  Gait comparison of unicompartmental and total knee arthroplasties with healthy controls.

Authors:  G G Jones; M Kotti; A V Wiik; R Collins; M J Brevadt; R K Strachan; J P Cobb
Journal:  Bone Joint J       Date:  2016-10       Impact factor: 5.082

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.