Literature DB >> 18662642

Closed-loop control of consciousness during lung transplantation: an observational study.

Ngai Liu1, Thierry Chazot, Bernard Trillat, Mireille Michel-Cherqui, Jean Yves Marandon, Jean-Dominique Law-Koune, Bertrand Rives, Marc Fischler.   

Abstract

OBJECTIVE: To determine if propofol infusion can be steered automatically by using bispectral index (BIS) as a controller during lung transplantation.
DESIGN: A prospective study of patients undergoing lung transplantation.
SETTING: University hospital. PARTICIPANTS: Twenty consecutive patients scheduled for bilateral (n = 14) or single (n = 6) lung transplantation.
INTERVENTIONS: The goal of the closed-loop administration of propofol was to maintain the BIS value between 40 and 60 during the maintenance phase. The remifentanil infusion was adjusted according to standard clinical practice.
MEASUREMENTS AND MAIN RESULTS: The closed-loop system was able to provide anesthesia maintenance for all patients. Cardiopulmonary bypass was used in 5 patients, and 14 patients received a thoracic epidural catheter. The BIS value was maintained between 40 and 60 during 84% +/- 16% of the maintenance phase. Eleven patients were extubated in the operating room, and 1 patient needed reintubation.
CONCLUSION: Closed-loop control of consciousness by a computer during lung transplantation is clinically feasible.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18662642     DOI: 10.1053/j.jvca.2008.04.022

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  11 in total

1.  Dynamic behavior of BIS, M-entropy and neuroSENSE brain function monitors.

Authors:  Stéphane Bibian; Guy A Dumont; Tatjana Zikov
Journal:  J Clin Monit Comput       Date:  2010-12-05       Impact factor: 2.502

2.  Bi-spectral index guided closed-loop anaesthesia delivery system (CLADS) in pheochromocytoma.

Authors:  Harihar V Hegde; G D Puri; Bhupesh Kumar; Arunanshu Behera
Journal:  J Clin Monit Comput       Date:  2009-06-11       Impact factor: 2.502

3.  A closed-loop anesthetic delivery system for real-time control of burst suppression.

Authors:  Max Y Liberman; Shinung Ching; Jessica Chemali; Emery N Brown
Journal:  J Neural Eng       Date:  2013-06-07       Impact factor: 5.379

4.  An enriched simulation environment for evaluation of closed-loop anesthesia.

Authors:  Mengqi Fang; Yuan Tao; Youqing Wang
Journal:  J Clin Monit Comput       Date:  2013-06-08       Impact factor: 2.502

5.  Anesthetic experience in patient for single lung transplantation with previous contralateral pneumonectomy -A case report-.

Authors:  Ji-Hyun Chung; Seung-Cheol Cha; Jin-Hwan Hwang; Seong Chang Woo
Journal:  Korean J Anesthesiol       Date:  2012-05-24

6.  Automated sedation outperforms manual administration of propofol and remifentanil in critically ill patients with deep sedation: a randomized phase II trial.

Authors:  Morgan Le Guen; Ngai Liu; Eric Bourgeois; Thierry Chazot; Daniel I Sessler; Jean-Jacques Rouby; Marc Fischler
Journal:  Intensive Care Med       Date:  2012-12-06       Impact factor: 17.440

7.  Real-time closed-loop control in a rodent model of medically induced coma using burst suppression.

Authors:  ShiNung Ching; Max Y Liberman; Jessica J Chemali; M Brandon Westover; Jonathan D Kenny; Ken Solt; Patrick L Purdon; Emery N Brown
Journal:  Anesthesiology       Date:  2013-10       Impact factor: 7.892

8.  A technical description of a novel pharmacological anesthesia robot.

Authors:  Mohamad Wehbe; Erik Arbeid; Shantale Cyr; Pierre A Mathieu; Riccardo Taddei; Joshua Morse; Thomas M Hemmerling
Journal:  J Clin Monit Comput       Date:  2013-06-15       Impact factor: 2.502

9.  Anesthetic management in lung transplantation: Our single-center experience.

Authors:  Atakan Erkılınç; Pınar Karaca Baysal; Mustafa Emre Gürcü
Journal:  Turk Gogus Kalp Damar Cerrahisi Derg       Date:  2021-04-26       Impact factor: 0.332

10.  Closed-loop control better than open-loop control of profofol TCI guided by BIS: a randomized, controlled, multicenter clinical trial to evaluate the CONCERT-CL closed-loop system.

Authors:  Yu Liu; Min Li; Dong Yang; Xuena Zhang; Anshi Wu; Shanglong Yao; Zhanggang Xue; Yun Yue
Journal:  PLoS One       Date:  2015-04-17       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.