Literature DB >> 23761951

Analysis of Uniformity of Magnetic Field Generated by the Two-Pair Coil System.

P Kędzia1, T Czechowski, M Baranowski, J Jurga, E Szcześniak.   

Abstract

In this paper we use a simple analysis based on properties of the axial field generated by symmetrical multipoles to reveal all possible distributions of two coaxial pairs of circular windings, which result in systems featuring zero octupole and 32 pole magnetic moments (six-order systems). Homogeneity of magnetic field of selected systems is analyzed. It has been found that one of the derived systems generates homogenous magnetic field whose volume is comparable to that yielded by the eight-order system. The influence of the current distribution and the windings placement on the field homogeneity is considered. The table, graphs and equations given in the paper facilitate the choice of the most appropriate design for a given problem. The systems presented may find applications in low field electron paramagnetic resonance imaging, some functional f-MRI (nuclear magnetic resonance imaging) and bioelectromagnetic experiments requiring the access to the working space from all directions.

Entities:  

Year:  2013        PMID: 23761951      PMCID: PMC3677240          DOI: 10.1007/s00723-012-0427-5

Source DB:  PubMed          Journal:  Appl Magn Reson        ISSN: 0937-9347            Impact factor:   0.831


  6 in total

1.  Improving the homogeneity of the magnetic field in the magnetic search coil technique.

Authors:  J Ditterich; T Eggert
Journal:  IEEE Trans Biomed Eng       Date:  2001-10       Impact factor: 4.538

2.  A four coil exposure system (tetracoil) producing a highly uniform magnetic field.

Authors:  G Gottardi; P Mesirca; C Agostini; D Remondini; F Bersani
Journal:  Bioelectromagnetics       Date:  2003-02       Impact factor: 2.010

3.  Uniform magnetic fields and double-wrapped coil systems: improved techniques for the design of bioelectromagnetic experiments.

Authors:  J L Kirschvink
Journal:  Bioelectromagnetics       Date:  1992       Impact factor: 2.010

4.  A System for Open-Access He Human Lung Imaging at Very Low Field.

Authors:  I C Ruset; L L Tsai; R W Mair; S Patz; M I Hrovat; M S Rosen; I Muradian; J Ng; G P Topulos; J P Butler; R L Walsworth; F W Hersman
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2006       Impact factor: 1.176

Review 5.  Gradient coil design: a review of methods.

Authors:  R Turner
Journal:  Magn Reson Imaging       Date:  1993       Impact factor: 2.546

6.  Magnet field profiling: analysis and correcting coil design.

Authors:  F Roméo; D I Hoult
Journal:  Magn Reson Med       Date:  1984-03       Impact factor: 4.668

  6 in total
  3 in total

1.  Design of a sustainable prepolarizing magnetic resonance imaging system for infant hydrocephalus.

Authors:  Johnes Obungoloch; Joshua R Harper; Steven Consevage; Igor M Savukov; Thomas Neuberger; Srinivas Tadigadapa; Steven J Schiff
Journal:  MAGMA       Date:  2018-04-11       Impact factor: 2.310

2.  Imaging of Subsurface Corrosion Using Gradient-Field Pulsed Eddy Current Probes with Uniform Field Excitation.

Authors:  Yong Li; Shuting Ren; Bei Yan; Ilham Mukriz Zainal Abidin; Yi Wang
Journal:  Sensors (Basel)       Date:  2017-07-31       Impact factor: 3.576

Review 3.  Approaches in cooling of resistive coil-based low-field Magnetic Resonance Imaging (MRI) systems for application in low resource settings.

Authors:  Faith Natukunda; Theodora M Twongyirwe; Steven J Schiff; Johnes Obungoloch
Journal:  BMC Biomed Eng       Date:  2021-02-12