Literature DB >> 12524679

A four coil exposure system (tetracoil) producing a highly uniform magnetic field.

G Gottardi1, P Mesirca, C Agostini, D Remondini, F Bersani.   

Abstract

We propose a magnetic field exposure system (tetracoil) for in vitro and in vivo experiments, composed of two couples of circular coils satisfying a spherical constraint, whose characteristics are chosen in order to maximize the uniformity region of the magnetic field. Analytical calculations and computer simulations show that our system, as compared to the other most largely used magnetic field exposure systems, represents an optimal compromise in terms of field uniformity, accessibility for biological experiments, and ratio between overall dimension and uniformity region. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2003        PMID: 12524679     DOI: 10.1002/bem.10074

Source DB:  PubMed          Journal:  Bioelectromagnetics        ISSN: 0197-8462            Impact factor:   2.010


  6 in total

1.  Posture-dependent human 3He lung imaging in an open-access MRI system: initial results.

Authors:  Leo L Tsai; Ross W Mair; Chih-Hao Li; Matthew S Rosen; Samuel Patz; Ronald L Walsworth
Journal:  Acad Radiol       Date:  2008-06       Impact factor: 3.173

2.  An open-access, very-low-field MRI system for posture-dependent 3He human lung imaging.

Authors:  L L Tsai; R W Mair; M S Rosen; S Patz; R L Walsworth
Journal:  J Magn Reson       Date:  2008-05-24       Impact factor: 2.229

3.  Analysis of Uniformity of Magnetic Field Generated by the Two-Pair Coil System.

Authors:  P Kędzia; T Czechowski; M Baranowski; J Jurga; E Szcześniak
Journal:  Appl Magn Reson       Date:  2013-01-08       Impact factor: 0.831

4.  Design of a sustainable prepolarizing magnetic resonance imaging system for infant hydrocephalus.

Authors:  Johnes Obungoloch; Joshua R Harper; Steven Consevage; Igor M Savukov; Thomas Neuberger; Srinivas Tadigadapa; Steven J Schiff
Journal:  MAGMA       Date:  2018-04-11       Impact factor: 2.310

5.  SQUID-based detection of ultra-low-field multinuclear NMR of substances hyperpolarized using signal amplification by reversible exchange.

Authors:  K Buckenmaier; M Rudolph; C Back; T Misztal; U Bommerich; P Fehling; D Koelle; R Kleiner; H A Mayer; K Scheffler; J Bernarding; M Plaumann
Journal:  Sci Rep       Date:  2017-10-18       Impact factor: 4.379

6.  Hyperpolarised gas filling station for medical imaging using polarised 129Xe and 3He.

Authors:  Wai Tung Lee; Gang Zheng; Cavin L Talbot; Xin Tong; Tim D'Adam; Steven R Parnell; Michael de Veer; Graham Jenkin; Graeme R Polglase; Stuart B Hooper; Bruce R Thompson; Francis Thien; Gary F Egan
Journal:  Magn Reson Imaging       Date:  2021-02-15       Impact factor: 2.546

  6 in total