Evaluation of a minimally invasive system for measuring glucose area under the curve during oral glucose tolerance tests: usefulness of sweat monitoring for precise measurement.

Kazuhiko Sakaguchi1, Yushi Hirota, Naoko Hashimoto, Wataru Ogawa, Tomoya Hamaguchi, Toshihiro Matsuo, Jun-ichiro Miyagawa, Mitsuyoshi Namba, Toshiyuki Sato, Seiki Okada, Koji Tomita, Munehide Matsuhisa, Hideaki Kaneto, Keisuke Kosugi, Hiroshi Maegawa, Hiromu Nakajima, Atsunori Kashiwagi.   

Abstract

AIMS: We developed a system for measuring glucose area under the curve (AUC) using minimally invasive interstitial fluid extraction technology (MIET). Sweat contamination during interstitial fluid glucose (IG) extraction affects the accuracy of glucose AUC measurement, because this technology uses extracted sodium ion levels as an internal standard. Therefore, we developed a sweat monitoring patch to reduce this effect and investigated its efficacy in volunteers undergoing oral glucose tolerance tests (OGTTs).
MATERIALS AND METHODS: Fifty diabetes mellitus inpatients and 10 healthy subjects undergoing the 75 g OGTT were included. Two sites on the forearm were pretreated with microneedle arrays, then hydrogels for interstitial fluid extraction were placed on the treated sites. Simultaneously, hydrogels for sweat monitoring were placed on untreated sites near the treated sites. Plasma glucose (PG) levels were measured every 30 min for 2 h to calculate reference AUC values. Using MIET, IG AUC was calculated from extracted glucose and sodium ion levels after attachment of the hydrogel for 2 h.
RESULTS: Good correlation between IG AUC measurements using MIET and reference AUCs measured using PG levels was confirmed over a wide AUC range (202-610 mg/h/dl) after correction for the sweat-induced error detected by the hydrogel patches on the nonpretreated skin. Strong correlation between IG AUC and peak glucose levels indicates that glucose spikes can be easily detected by this system.
CONCLUSION: We confirmed the effectiveness of a sweat monitoring patch for precise AUC measurement using MIET. This novel, easy-to-use system has potential for glucose excursion evaluation in daily clinical practice.
© 2013 Diabetes Technology Society.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23759401      PMCID: PMC3869136          DOI: 10.1177/193229681300700313

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  22 in total

Review 1.  Standards of medical care in diabetes--2012.

Authors: 
Journal:  Diabetes Care       Date:  2012-01       Impact factor: 19.112

2.  Correlation between sweat glucose and blood glucose in subjects with diabetes.

Authors:  James Moyer; Donald Wilson; Irina Finkelshtein; Bruce Wong; Russell Potts
Journal:  Diabetes Technol Ther       Date:  2012-02-29       Impact factor: 6.118

Review 3.  Technologies for continuous glucose monitoring: current problems and future promises.

Authors:  Santhisagar Vaddiraju; Diane J Burgess; Ioannis Tomazos; Faquir C Jain; Fotios Papadimitrakopoulos
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

4.  A minimally invasive system for glucose area under the curve measurement using interstitial fluid extraction technology: evaluation of the accuracy and usefulness with oral glucose tolerance tests in subjects with and without diabetes.

Authors:  Kazuhiko Sakaguchi; Yushi Hirota; Naoko Hashimoto; Wataru Ogawa; Toshiyuki Sato; Seiki Okada; Kei Hagino; Yoshihiro Asakura; Yasuo Kikkawa; Junko Kojima; Yasunori Maekawa; Hiromu Nakajima
Journal:  Diabetes Technol Ther       Date:  2012-04-26       Impact factor: 6.118

5.  Pilot studies of transdermal continuous glucose measurement in outpatient diabetic patients and in patients during and after cardiac surgery.

Authors:  Han Chuang; My-Quyen Trieu; James Hurley; Elizabeth J Taylor; Michael R England; Stanley A Nasraway
Journal:  J Diabetes Sci Technol       Date:  2008-07

6.  Risk factors for myocardial infarction and death in newly detected NIDDM: the Diabetes Intervention Study, 11-year follow-up.

Authors:  M Hanefeld; S Fischer; U Julius; J Schulze; U Schwanebeck; H Schmechel; H J Ziegelasch; J Lindner
Journal:  Diabetologia       Date:  1996-12       Impact factor: 10.122

7.  Detection of hypoglycemia with the GlucoWatch biographer.

Authors:  K R Pitzer; S Desai; T Dunn; S Edelman; Y Jayalakshmi; J Kennedy; J A Tamada; R O Potts
Journal:  Diabetes Care       Date:  2001-05       Impact factor: 19.112

Review 8.  An overview of minimally invasive technologies.

Authors:  B H Ginsberg
Journal:  Clin Chem       Date:  1992-09       Impact factor: 8.327

9.  Acarbose for prevention of type 2 diabetes mellitus: the STOP-NIDDM randomised trial.

Authors:  Jean-Louis Chiasson; Robert G Josse; Ramon Gomis; Markolf Hanefeld; Avraham Karasik; Markku Laakso
Journal:  Lancet       Date:  2002-06-15       Impact factor: 79.321

Review 10.  Management of hyperglycemia in type 2 diabetes: a patient-centered approach: position statement of the American Diabetes Association (ADA) and the European Association for the Study of Diabetes (EASD).

Authors:  Silvio E Inzucchi; Richard M Bergenstal; John B Buse; Michaela Diamant; Ele Ferrannini; Michael Nauck; Anne L Peters; Apostolos Tsapas; Richard Wender; David R Matthews
Journal:  Diabetes Care       Date:  2012-04-19       Impact factor: 19.112

View more
  9 in total

Review 1.  Wearable biosensors for healthcare monitoring.

Authors:  Jayoung Kim; Alan S Campbell; Berta Esteban-Fernández de Ávila; Joseph Wang
Journal:  Nat Biotechnol       Date:  2019-02-25       Impact factor: 54.908

2.  Soft, skin-mounted microfluidic systems for measuring secretory fluidic pressures generated at the surface of the skin by eccrine sweat glands.

Authors:  Jungil Choi; Yeguang Xue; Wei Xia; Tyler R Ray; Jonathan T Reeder; Amay J Bandodkar; Daeshik Kang; Shuai Xu; Yonggang Huang; John A Rogers
Journal:  Lab Chip       Date:  2017-07-25       Impact factor: 6.799

3.  A stretchable and screen-printed electrochemical sensor for glucose determination in human perspiration.

Authors:  A Abellán-Llobregat; Itthipon Jeerapan; A Bandodkar; L Vidal; A Canals; J Wang; E Morallón
Journal:  Biosens Bioelectron       Date:  2017-01-26       Impact factor: 10.618

4.  Three-dimensional paper-based microfluidic electrochemical integrated devices (3D-PMED) for wearable electrochemical glucose detection.

Authors:  Qingpeng Cao; Bo Liang; Tingting Tu; Jinwei Wei; Lu Fang; Xuesong Ye
Journal:  RSC Adv       Date:  2019-02-14       Impact factor: 4.036

5.  A graphene-based electrochemical device with thermoresponsive microneedles for diabetes monitoring and therapy.

Authors:  Hyunjae Lee; Tae Kyu Choi; Young Bum Lee; Hye Rim Cho; Roozbeh Ghaffari; Liu Wang; Hyung Jin Choi; Taek Dong Chung; Nanshu Lu; Taeghwan Hyeon; Seung Hong Choi; Dae-Hyeong Kim
Journal:  Nat Nanotechnol       Date:  2016-03-21       Impact factor: 39.213

6.  Evaluation of a Novel Glucose Area Under the Curve (AUC) Monitoring System: Comparison with the AUC by Continuous Glucose Monitoring.

Authors:  Satoshi Ugi; Hiroshi Maegawa; Katsutaro Morino; Yoshihiko Nishio; Toshiyuki Sato; Seiki Okada; Yasuo Kikkawa; Toshihiro Watanabe; Hiromu Nakajima; Atsunori Kashiwagi
Journal:  Diabetes Metab J       Date:  2016-07-26       Impact factor: 5.376

7.  A thermal activated and differential self-calibrated flexible epidermal biomicrofluidic device for wearable accurate blood glucose monitoring.

Authors:  Zhihua Pu; Xingguo Zhang; Haixia Yu; Jiaan Tu; Hailong Chen; Yuncong Liu; Xiao Su; Ridong Wang; Lei Zhang; Dachao Li
Journal:  Sci Adv       Date:  2021-01-27       Impact factor: 14.136

8.  Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients.

Authors:  Mei Uemura; Yutaka Yano; Toshinari Suzuki; Taro Yasuma; Toshiyuki Sato; Aya Morimoto; Samiko Hosoya; Chihiro Suminaka; Hiromu Nakajima; Esteban C Gabazza; Yoshiyuki Takei
Journal:  Diabetes Metab J       Date:  2017-08       Impact factor: 5.376

9.  Wearable/disposable sweat-based glucose monitoring device with multistage transdermal drug delivery module.

Authors:  Hyunjae Lee; Changyeong Song; Yong Seok Hong; Minsung Kim; Hye Rim Cho; Taegyu Kang; Kwangsoo Shin; Seung Hong Choi; Taeghwan Hyeon; Dae-Hyeong Kim
Journal:  Sci Adv       Date:  2017-03-08       Impact factor: 14.957

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.