Literature DB >> 23749649

Impact of a 4th generation iterative reconstruction technique on image quality in low-dose computed tomography of the chest in immunocompromised patients.

A Laqmani1, J H Buhk, F O Henes, T Klink, S Sehner, H C von Schultzendorff, D Hammerle, H D Nagel, G Adam, M Regier.   

Abstract

PURPOSE: To determine the image quality of an iterative reconstruction (IR) technique in low-dose MDCT (LDCT) of the chest of immunocompromised patients in an intraindividual comparison to filtered back projection (FBP) and to evaluate the dose reduction capability.
MATERIALS AND METHODS: 30 chest LDCT scans were performed in immunocompromised patients (Brilliance iCT; 20-40 mAs; mean CTDIvol: 1.7 mGy). The raw data were reconstructed using FBP and the IR technique (iDose4™, Philips, Best, The Netherlands) set to seven iteration levels. 30 routine-dose MDCT (RDCT) reconstructed with FBP served as controls (mean exposure: 116 mAs; mean CDTIvol: 7.6 mGy). Three blinded radiologists scored subjective image quality and lesion conspicuity. Quantitative parameters including CT attenuation and objective image noise (OIN) were determined.
RESULTS: In LDCT high iDose4™ levels lead to a significant decrease in OIN (FBP vs. iDose7: subscapular muscle 139.4 vs. 40.6 HU). The high iDose4™ levels provided significant improvements in image quality and artifact and noise reduction compared to LDCT FBP images. The conspicuity of subtle lesions was limited in LDCT FBP images. It significantly improved with high iDose4™ levels (> iDose4). LDCT with iDose4™ level 6 was determined to be of equivalent image quality as RDCT with FBP.
CONCLUSION: iDose4™ substantially improves image quality and lesion conspicuity and reduces noise in low-dose chest CT. Compared to RDCT, high iDose4™ levels provide equivalent image quality in LDCT, hence suggesting a potential dose reduction of almost 80%. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2013        PMID: 23749649     DOI: 10.1055/s-0033-1335577

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  13 in total

1.  Reduced-dose abdominopelvic CT using hybrid iterative reconstruction in suspected left-sided colonic diverticulitis.

Authors:  Azien Laqmani; Simon Veldhoen; Simon Dulz; Thorsten Derlin; Cyrus Behzadi; Jakob Schmidt-Holtz; Felicia Wassenberg; Susanne Sehner; Hans-Dieter Nagel; Gerhard Adam; Marc Regier
Journal:  Eur Radiol       Date:  2015-06-13       Impact factor: 5.315

Review 2.  Imaging of multiple myeloma: Current concepts.

Authors:  Thorsten Derlin; Peter Bannas
Journal:  World J Orthop       Date:  2014-07-18

3.  A Practice Quality Improvement Project: Reducing Dose of Routine Chest CT Imaging in a Busy Clinical Practice.

Authors:  Edwin A Takahashi; Marc D Kohli; Shawn D Teague
Journal:  J Digit Imaging       Date:  2016-10       Impact factor: 4.056

4.  Comparison of conventional radiography and MDCT in suspected scaphoid fractures.

Authors:  Cyrus Behzadi; Murat Karul; Frank Oliver Henes; Azien Laqmani; Philipp Catala-Lehnen; Wolfgang Lehmann; Hans-Dieter Nagel; Gerhard Adam; Marc Regier
Journal:  World J Radiol       Date:  2015-01-28

Review 5.  The role of advanced reconstruction algorithms in cardiac CT.

Authors:  Sandra S Halliburton; Yuki Tanabe; Sasan Partovi; Prabhakar Rajiah
Journal:  Cardiovasc Diagn Ther       Date:  2017-10

Review 6.  Computed tomography dose optimisation in cystic fibrosis: A review.

Authors:  Helena Ferris; Maria Twomey; Fiachra Moloney; Siobhan B O'Neill; Kevin Murphy; Owen J O'Connor; Michael Maher
Journal:  World J Radiol       Date:  2016-04-28

Review 7.  Computed tomography in cystic fibrosis lung disease: a focus on radiation exposure.

Authors:  Stella Joyce; Brian W Carey; Niamh Moore; David Mullane; Michael Moore; Mark F McEntee; Barry J Plant; Michael M Maher; Owen J O'Connor
Journal:  Pediatr Radiol       Date:  2021-03-20

8.  Fully automated image quality evaluation on patient CT: Multi-vendor and multi-reconstruction study.

Authors:  Minsoo Chun; Jin Hwa Choi; Sihwan Kim; Chulkyun Ahn; Jong Hyo Kim
Journal:  PLoS One       Date:  2022-07-20       Impact factor: 3.752

9.  Ultra Low Dose CT Pulmonary Angiography with Iterative Reconstruction.

Authors:  Andreas Sauter; Thomas Koehler; Alexander A Fingerle; Bernhard Brendel; Vivien Richter; Michael Rasper; Ernst J Rummeny; Peter B Noël; Daniela Münzel
Journal:  PLoS One       Date:  2016-09-09       Impact factor: 3.240

10.  A comparative study based on image quality and clinical task performance for CT reconstruction algorithms in radiotherapy.

Authors:  Hua Li; Steven Dolly; Hsin-Chen Chen; Mark A Anastasio; Daniel A Low; Harold H Li; Jeff M Michalski; Wade L Thorstad; Hiram Gay; Sasa Mutic
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.