Literature DB >> 23748313

The effect of healing abutment reconnection and disconnection on soft and hard peri-implant tissues: a short-term randomized controlled clinical trial.

Theofilos Koutouzis1, Giasemi Koutouzis, Hana Gadalla, Rodrigo Neiva.   

Abstract

PURPOSE: It has been reported that multiple abutment disconnections and reconnections following implant placement may compromise the peri-implant mucosal seal and may lead to increased marginal bone loss. Thus, the aim of this study was to evaluate the effect of healing abutment disconnection and reconnection on soft and hard peri-implant tissues.
MATERIALS AND METHODS: Sixteen patients were included in this prospective randomized controlled clinical trial. Following one-stage implant placement, test group implants (n = 10) received a permanent abutment and control group implants (n = 11) received a healing abutment. After 2 months of healing, control group implants underwent a prosthetic protocol involving implant-level impressions and a two-time abutment disconnection and reconnection process prior to delivery of the definitive prosthesis. Test group implants underwent a prosthetic protocol involving abutment-level impressions without any abutment disconnection. Clinical parameters were recorded at 2 weeks, 2 months, 3 months, and 6 months, and marginal bone levels were assessed radiographically at implant placement, 3 months, and 6 months.
RESULTS: The overall survival rate from implant placement to the last follow-up visit was 100% for both groups. The mean marginal bone loss at the 6-month examination was 0.13 mm for test group implants and 0.28 mm for control group implants. There were no significant differences regarding changes in peri-implant mucosal dimensions between the two groups.
CONCLUSION: The present study indicates that implants receiving a final abutment at the time of implant placement exhibited minimal marginal bone loss and were similar to implants subjected to abutment disconnection and reconnection two times. Disconnection and reconnection of the abutment two times did not cause negative dimensional changes in the peri-implant mucosa.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23748313     DOI: 10.11607/jomi.3022

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  9 in total

1.  Validation of an implant stability measurement device using the percussion response: a clinical research study.

Authors:  Yurie Okuhama; Koudai Nagata; Hyunjin Kim; Hayato Tsuruoka; Mihoko Atsumi; Hiromasa Kawana
Journal:  BMC Oral Health       Date:  2022-07-14       Impact factor: 3.747

2.  Relationship between implant stability on the abutment and platform level by means of resonance frequency analysis: A cross-sectional study.

Authors:  Frederico Santos Lages; Dhelfeson Willya Douglas-de-Oliveira; Guilherme Siqueira Ibelli; Fatimah Assaf; Thallita Pereira Queiroz; Fernando Oliveira Costa
Journal:  PLoS One       Date:  2017-07-24       Impact factor: 3.240

Review 3.  One-time versus repeated abutment connection for platform-switched implant: A systematic review and meta-analysis.

Authors:  Qing-Qing Wang; Ruoxi Dai; Chris Ying Cao; Hui Fang; Min Han; Quan-Li Li
Journal:  PLoS One       Date:  2017-10-19       Impact factor: 3.240

4.  Clinical and Radiological Evaluation of Delayed and Early Loading of Single-Tooth Implant Placement: A 6-Month, Prospective, Randomized, Follow-up Clinical Study.

Authors:  Santhosh Sekar; Thangakumaran Suthanthiran; Arthiie Thangavelu; Sasi Kumar Karupannan; Fairlin Prem; Dhivya Rajendran
Journal:  J Pharm Bioallied Sci       Date:  2019-05

5.  One Abutment One Time: A Multicenter, Prospective, Controlled, Randomized Study.

Authors:  José Vicente Ríos-Santos; Gregorio Tello-González; Pedro Lázaro-Calvo; Francisco Javier Gil Mur; Blanca Ríos-Carrasco; Ana Fernández-Palacín; Mariano Herrero-Climent
Journal:  Int J Environ Res Public Health       Date:  2020-12-17       Impact factor: 3.390

6.  Comparative evaluation of peri-implant tissues in definitive and repeated abutment replacements: A randomized clinical trial.

Authors:  Prachi Rajendra Rathi; Rajashri Abhay Kolte; Abhay Pandurang Kolte
Journal:  J Indian Soc Periodontol       Date:  2022-01-01

7.  The Association of the One-Abutment at One-Time Concept with Marginal Bone Loss around the SLA and Platform Switch and Conical Abutment Implants.

Authors:  Nasreen Hamudi; Eitan Barnea; Evgeny Weinberg; Amir Laviv; Eitan Mijiritsky; Shlomo Matalon; Liat Chaushu; Roni Kolerman
Journal:  J Clin Med       Date:  2021-12-24       Impact factor: 4.241

8.  Digital vs. conventional workflow for one-abutment one-time immediate restoration in the esthetic zone: a randomized controlled trial.

Authors:  Brieuc Hanozin; Lou Li Manni; Geoffrey Lecloux; Miljana Bacevic; France Lambert
Journal:  Int J Implant Dent       Date:  2022-02-07

9.  A Retrospective Observational Study Assessing the Clinical Outcomes of a Novel Implant System with Low-Speed Site Preparation Protocol and Tri-Oval Implant Geometry.

Authors:  Giacomo Fabbri; Tristan Staas; Istvan Urban
Journal:  J Clin Med       Date:  2022-08-18       Impact factor: 4.964

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.