Literature DB >> 23740025

A prospective feasibility study of sub-millisievert abdominopelvic CT using iterative reconstruction in Crohn's disease.

Siobhan B O'Neill1, Patrick D Mc Laughlin, Lee Crush, Owen J O'Connor, Sebastian R Mc Williams, Orla Craig, Anne Marie Mc Garrigle, Fiona O'Neill, Jackie Bye, Max F Ryan, Fergus Shanahan, Michael M Maher.   

Abstract

OBJECTIVE: Iterative reconstruction (IR) allows diagnostic CT imaging with less radiation exposure than filtered back projection (FBP). We studied an IR low-dose CT abdomen/pelvis (LDCTAP) protocol, designed to image at an effective dose (ED) approximating 1 mSv in patients with Crohn's disease (CD).
METHODS: Forty patients, mean age 37 ± 13.4 years (range 17-69), with CD underwent two synchronous CT protocols (conventional-dose (CDCTAP) and LDCTAP). CDCTAP and LDCTAP images were compared for diagnostic acceptability, yield, image quality and ED (in millisieverts). The optimal level of IR for LDCTAP was also studied.
RESULTS: LDCTAP yielded a mean ED of 1.3 ± 0.8 mSv compared with 4.7 ± 2.9 mSv for CDCTAP, reducing ED by 73.7 ± 3.3 % (mean dose reduction, 3.5 ± 2.1 mSv; P < 0.001) and dose length product by 73.6 ± 2.6 % (P < 0.001). Sub-millisievert (0.84 mSv) imaging was performed for patients with a body mass index (BMI) less than 25 (i.e. 63 % of our cohort). LDCTAP resulted in increased image noise and reduced diagnostic acceptability compared with CDCTAP despite use of IR, but detection of extra-luminal complications was comparable.
CONCLUSION: Patients with suspected active CD can be adequately imaged using LDCTAP, yielding comparable information regarding extent, activity and complications of CD compared with CDCTAP, but with 74 % less dose. LDCTAP at doses equivalent to that of two abdominal radiographs represents a feasible alternative to CDCTAP. KEY POINTS: • Radiation dose is a concern when imaging patients with Crohn's disease. • New techniques allow low-dose abdominopelvic CT with acceptable image quality. • Using hybrid iterative reconstruction, its diagnostic yield compares well with that of conventional CT. • Sub-millisievert CT of patients with Crohn's disease appears technically and clinically feasible.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23740025     DOI: 10.1007/s00330-013-2858-2

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  32 in total

1.  Comparison of Z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis.

Authors:  Mannudeep K Kalra; Michael M Maher; Thomas L Toth; Ravi S Kamath; Elkan F Halpern; Sanjay Saini
Journal:  Radiology       Date:  2004-08       Impact factor: 11.105

2.  Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients.

Authors:  Yoshiko Sagara; Amy K Hara; William Pavlicek; Alvin C Silva; Robert G Paden; Qing Wu
Journal:  AJR Am J Roentgenol       Date:  2010-09       Impact factor: 3.959

3.  Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique.

Authors:  Priyanka Prakash; Mannudeep K Kalra; Avinash K Kambadakone; Homer Pien; Jiang Hsieh; Michael A Blake; Dushyant V Sahani
Journal:  Invest Radiol       Date:  2010-04       Impact factor: 6.016

Review 4.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

Review 5.  Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm.

Authors:  Alvin C Silva; Holly J Lawder; Amy Hara; Jennifer Kujak; William Pavlicek
Journal:  AJR Am J Roentgenol       Date:  2010-01       Impact factor: 3.959

6.  Selection of symptomatic patients with Crohn's disease for abdominopelvic computed tomography: role of serum C-reactive protein.

Authors:  Alan N Desmond; Kevin O'Regan; Neera Malik; Sebastian McWilliams; Siobhan O'Neill; Eamonn M Quigley; Fergus Shanahan; Michael M Maher
Journal:  Can Assoc Radiol J       Date:  2012-03-14       Impact factor: 2.248

7.  Lower tube voltage reduces contrast material and radiation doses on 16-MDCT aortography.

Authors:  Yoshiharu Nakayama; Kazuo Awai; Yoshinori Funama; Duo Liu; Takeshi Nakaura; Yoshitaka Tamura; Yasuyuki Yamashita
Journal:  AJR Am J Roentgenol       Date:  2006-11       Impact factor: 3.959

8.  The 15-Country Collaborative Study of Cancer Risk among Radiation Workers in the Nuclear Industry: estimates of radiation-related cancer risks.

Authors:  E Cardis; M Vrijheid; M Blettner; E Gilbert; M Hakama; C Hill; G Howe; J Kaldor; C R Muirhead; M Schubauer-Berigan; T Yoshimura; F Bermann; G Cowper; J Fix; C Hacker; B Heinmiller; M Marshall; I Thierry-Chef; D Utterback; Y-O Ahn; E Amoros; P Ashmore; A Auvinen; J-M Bae; J Bernar; A Biau; E Combalot; P Deboodt; A Diez Sacristan; M Eklöf; H Engels; G Engholm; G Gulis; R R Habib; K Holan; H Hyvonen; A Kerekes; J Kurtinaitis; H Malker; M Martuzzi; A Mastauskas; A Monnet; M Moser; M S Pearce; D B Richardson; F Rodriguez-Artalejo; A Rogel; H Tardy; M Telle-Lamberton; I Turai; M Usel; K Veress
Journal:  Radiat Res       Date:  2007-04       Impact factor: 2.841

9.  Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction techniques.

Authors:  Sarabjeet Singh; Mannudeep K Kalra; Jiang Hsieh; Paul E Licato; Synho Do; Homer H Pien; Michael A Blake
Journal:  Radiology       Date:  2010-09-09       Impact factor: 11.105

10.  MR imaging of the small bowel.

Authors:  Jeff L Fidler; Luis Guimaraes; David M Einstein
Journal:  Radiographics       Date:  2009-10       Impact factor: 5.333

View more
  16 in total

1.  Reduced-dose abdominopelvic CT using hybrid iterative reconstruction in suspected left-sided colonic diverticulitis.

Authors:  Azien Laqmani; Simon Veldhoen; Simon Dulz; Thorsten Derlin; Cyrus Behzadi; Jakob Schmidt-Holtz; Felicia Wassenberg; Susanne Sehner; Hans-Dieter Nagel; Gerhard Adam; Marc Regier
Journal:  Eur Radiol       Date:  2015-06-13       Impact factor: 5.315

Review 2.  Dose reduction in pediatric abdominal CT: use of iterative reconstruction techniques across different CT platforms.

Authors:  Ranish Deedar Ali Khawaja; Sarabjeet Singh; Alexi Otrakji; Atul Padole; Ruth Lim; Katherine Nimkin; Sjirk Westra; Mannudeep K Kalra; Michael S Gee
Journal:  Pediatr Radiol       Date:  2014-11-27

3.  Iterative reconstruction improves image quality and preserves diagnostic accuracy in the setting of blunt solid organ injuries.

Authors:  Scott D Steenburg; Scott Persohn; Changyu Shen; Jeff W Dunkle; Sean D Gussick; Matthew J Petersen; Amy Wisnewski-Rhodes; Ryan T Whitesell
Journal:  Emerg Radiol       Date:  2014-06-07

4.  Low-dose CT imaging of the acute abdomen using model-based iterative reconstruction: a prospective study.

Authors:  Fiachra Moloney; Karl James; Maria Twomey; David Ryan; Tyler M Grey; Amber Downes; Richard G Kavanagh; Niamh Moore; Mary Jane Murphy; Jackie Bye; Brian W Carey; Sean E McSweeney; Conor Deasy; Emmett Andrews; Fergus Shanahan; Michael M Maher; Owen J O'Connor
Journal:  Emerg Radiol       Date:  2018-11-17

5.  Cumulative radiation exposure from diagnostic imaging in intensive care unit patients.

Authors:  Fiachra Moloney; Daniel Fama; Maria Twomey; Ruth O'Leary; Conor Houlihane; Kevin P Murphy; Siobhan B O'Neill; Owen J O'Connor; Dorothy Breen; Michael M Maher
Journal:  World J Radiol       Date:  2016-04-28

Review 6.  Computed tomography dose optimisation in cystic fibrosis: A review.

Authors:  Helena Ferris; Maria Twomey; Fiachra Moloney; Siobhan B O'Neill; Kevin Murphy; Owen J O'Connor; Michael Maher
Journal:  World J Radiol       Date:  2016-04-28

7.  The utilisation and diagnostic yield of radiological imaging in a specialist functional GI disorder clinic: an 11-year retrospective study.

Authors:  Micheal Breen; Kevin P Murphy; Siobhan B O'Neill; Joanne P O'Donovan; Sebastian McWilliams; Alan N Desmond; Fergus Shanahan; Eamonn M Quigley; Michael M Maher
Journal:  Eur Radiol       Date:  2014-07-25       Impact factor: 5.315

8.  Inflammatory bowel disease-the role of cross-sectional imaging techniques in the investigation of the small bowel.

Authors:  Athanasios Athanasakos; Argyro Mazioti; Nikolaos Economopoulos; Christina Kontopoulou; Georgios Stathis; Dimitrios Filippiadis; Themistoklis Spyridopoulos; Efthymia Alexopoulou
Journal:  Insights Imaging       Date:  2014-12-24

9.  Effects of oral contrast on dose in abdominopelvic computed tomography with pure iterative reconstruction.

Authors:  Kevin P Murphy; Liam J Healy; Lee Crush; Maria Twomey; Fiachra Moloney; Sylvia Sexton; Owen J O'Connor; Michael M Maher
Journal:  World J Radiol       Date:  2016-09-28

10.  Crohn's disease Activity: Abdominal Computed Tomography Histopathology Correlation.

Authors:  N Paquet; J N Glickman; S M Erturk; P R Ros; J T Heverhagen; M A Patak
Journal:  Eur J Radiol Open       Date:  2016-04-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.