Literature DB >> 23733430

Effect of proximal contact strength on the three-dimensional displacements of implant-supported cantilever fixed partial dentures under axial loading.

Zhen-zhen Peng1, Xin-min Chen, Jun Wang, Ai-jie Li, Zu-jie Xu.   

Abstract

OBJECTIVE: This study investigated the effect of proximal contact strength on the three-dimensional displacements of cantilever fixed partial denture (CFPD) under vertically concentrated loading with digital laser speckle (DLS) technique.
METHODS: Fresh mandible of beagle dog was used to establish the implant-supported CFPD for specimen. DLS technique was employed for measuring the three-dimensional displacement of the prosthesis under vertically concentrated loading ranging from 200 to 3000 g. The effect of the contact tightness on the displacement of CFPD was investigated by means of changing the contact tightness.
RESULTS: When an axial concentrated loading was exerted on the pontic of the implant-supported CFPD, the displacement of the CFPD was the greatest. The displacement of the prosthesis decreased with the increase of contact strength. When the contact strength was 0, 0.95, and 3.25 N, the displacement of the buccolingual direction was smaller than that of the mesiodistal direction but greater than that of the occlusogingival direction. When the force on the contact area was 6.50 N, the mesiodistal displacement of the prosthesis was the biggest while the buccolingual displacement was the smallest.
CONCLUSIONS: The implant-supported CFPD is an effective therapy for fully or partially edentulous patients. The restoration of the contact area and the selection of the appropriate contact strength can reduce the displacement of the CFPD, and get a better stress distribution. The most appropriate force value is 3.25 N in this study.

Entities:  

Mesh:

Year:  2013        PMID: 23733430      PMCID: PMC3682169          DOI: 10.1631/jzus.B1200264

Source DB:  PubMed          Journal:  J Zhejiang Univ Sci B        ISSN: 1673-1581            Impact factor:   3.066


  26 in total

1.  Measurement of the physiological mobility of individual teeth in an axial direction.

Authors:  G J PARFITT
Journal:  J Dent Res       Date:  1960 May-Jun       Impact factor: 6.116

2.  Cantilever fixed prostheses utilizing dental implants: a 10-year retrospective analysis.

Authors:  Curtis M Becker
Journal:  Quintessence Int       Date:  2004-06       Impact factor: 1.677

3.  Finite element analysis of fixed partial denture replacement.

Authors:  S A Romeed; S L Fok; N H F Wilson
Journal:  J Oral Rehabil       Date:  2004-12       Impact factor: 3.837

4.  Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws.

Authors:  R Adell; B Eriksson; U Lekholm; P I Brånemark; T Jemt
Journal:  Int J Oral Maxillofac Implants       Date:  1990       Impact factor: 2.804

5.  Methods to improve a periodontally involved terminal abutment of a cantilever fixed partial denture--a finite element stress analysis.

Authors:  C H Wang; H E Lee; C C Wang; H P Chang
Journal:  J Oral Rehabil       Date:  1998-04       Impact factor: 3.837

6.  Biological factors contributing to failures of osseointegrated oral implants. (I). Success criteria and epidemiology.

Authors:  M Esposito; J M Hirsch; U Lekholm; P Thomsen
Journal:  Eur J Oral Sci       Date:  1998-02       Impact factor: 2.612

7.  Three-dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown.

Authors:  M Sevimay; F Turhan; M A Kiliçarslan; G Eskitascioglu
Journal:  J Prosthet Dent       Date:  2005-03       Impact factor: 3.426

8.  The biomechanics of force distribution in implant-supported prostheses.

Authors:  L A Weinberg
Journal:  Int J Oral Maxillofac Implants       Date:  1993       Impact factor: 2.804

9.  Complications in the tissue integrated prostheses components: clinical and mechanical evaluation.

Authors:  D Kohavi
Journal:  J Oral Rehabil       Date:  1993-07       Impact factor: 3.837

10.  The influence of occlusal loading location on stresses transferred to implant-supported prostheses and supporting bone: A three-dimensional finite element study.

Authors:  Gurcan Eskitascioglu; Aslihan Usumez; Mujde Sevimay; Emel Soykan; Elif Unsal
Journal:  J Prosthet Dent       Date:  2004-02       Impact factor: 3.426

View more