Literature DB >> 23730423

Vertical fracture of the mandibular posterior ramus border secondary to the stress of the rigid internal fixation material.

Metin Sencimen1, Aydin Gulses, Hasan Ayberk Altug.   

Abstract

A unique case of a vertical fracture of the mandibular posterior ramus border secondary to the stress of the rigid internal fixation material is described in this study. We think that the surgeon's experience and awareness play a key role in avoidance of such a complication.

Entities:  

Keywords:  orthognathic surgery; rigid internal fixation

Year:  2012        PMID: 23730423      PMCID: PMC3444017          DOI: 10.1055/s-0032-1313365

Source DB:  PubMed          Journal:  Craniomaxillofac Trauma Reconstr        ISSN: 1943-3875


  7 in total

Review 1.  Stability of orthognathic surgery: a review of rigid fixation.

Authors:  J E Van Sickels; D A Richardson
Journal:  Br J Oral Maxillofac Surg       Date:  1996-08       Impact factor: 1.651

2.  Three lateral osteotomy designs for bilateral sagittal split osteotomy: biomechanical evaluation with three-dimensional finite element analysis.

Authors:  Hiromasa Takahashi; Shigeaki Moriyama; Haruhiko Furuta; Hisao Matsunaga; Yuki Sakamoto; Toshihiro Kikuta
Journal:  Head Face Med       Date:  2010-03-26       Impact factor: 2.151

3.  Cone-beam computerized tomography evaluation of condylar changes and stability following two-jaw surgery: Le Fort I osteotomy and mandibular setback surgery with rigid fixation.

Authors:  Yong-Il Kim; Bong-Hae Cho; Yun-Hoa Jung; Woo-Sung Son; Soo-Byung Park
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2010-11-05

4.  A comparison of synovial fluid pressure after immediate versus gradual mandibular advancement in the miniature pig.

Authors:  Alan S Herford; Robert Hoffman; Samuel Demirdji; Philip J Boyne; Joseph M Caruso; V Leroy Leggitt; Luis Vega
Journal:  J Oral Maxillofac Surg       Date:  2005-06       Impact factor: 1.895

5.  Postoperative stability after sagittal split ramus osteotomies for a mandibular setback with monocortical plate fixation or bicortical screw fixation.

Authors:  Il-Hyuk Chung; Chung-Kyu Yoo; Eun-Kyung Lee; Jong-An Ihm; Chang-Joo Park; Ji-Sun Lim; Kyung-Gyun Hwang
Journal:  J Oral Maxillofac Surg       Date:  2008-03       Impact factor: 1.895

6.  Semirigid fixation of mandible and maxilla in orthognathic surgery: stability and advantages.

Authors:  Mehmet Emin Mavili; Halil Ibrahim Canter; Banu Saglam-Aydinatay
Journal:  Ann Plast Surg       Date:  2009-10       Impact factor: 1.539

7.  The fate of titanium miniplates and screws used in maxillofacial surgery: a 10 year retrospective study.

Authors:  J O'Connell; C Murphy; O Ikeagwuani; C Adley; G Kearns
Journal:  Int J Oral Maxillofac Surg       Date:  2009-03-21       Impact factor: 2.789

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.