Literature DB >> 23709356

A hybrid framework for registration of carotid ultrasound images combining iconic and geometric features.

Anupama Gupta1, Harsh K Verma, Savita Gupta.   

Abstract

Stroke is the third major cause of death worldwide behind heart disease and cancer. Carotid atherosclerosis is the most frequent cause of ischemic stroke. Early diagnosis of carotid plaque and serial monitoring of its size with the help of imaging modalities can help to prevent the atherosclerotic complications. The main difficulty is inevitable variability of patient's head positions during image acquisitions. The time series registration of carotid images helps to improve the monitoring, characterization, and quantification of the disease by suppressing the global movements of the patient. In this work, a novel hybrid registration technique has been proposed and evaluated for registration of carotid ultrasound images taken at different times. The proposed hybrid method bridges the gap between the feature-based and intensity-based registration methods. The feature-based iterative closest point algorithm is used to provide a coarse registration which is subsequently refined by the intensity-based algorithm. The proposed framework uses rigid transformation model coupled with mutual information (MI) similarity measure and Powell optimizer. For quantitative evaluation, different registration approaches have been compared using four error metrics: visual information fidelity, structural similarity index, correlation coefficient, and MI. Qualitative evaluation has also been done using the visual examination of the registered image pairs.

Entities:  

Mesh:

Year:  2013        PMID: 23709356     DOI: 10.1007/s11517-013-1086-x

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  12 in total

1.  Evaluation of voxel-based registration of 3-D power Doppler ultrasound and 3-D magnetic resonance angiographic images of carotid arteries.

Authors:  P J Slomka; J Mandel; D Downey; A Fenster
Journal:  Ultrasound Med Biol       Date:  2001-07       Impact factor: 2.998

2.  Coupling dense and landmark-based approaches for nonrigid registration.

Authors:  Pierre Hellier; Christian Barillot
Journal:  IEEE Trans Med Imaging       Date:  2003-02       Impact factor: 10.048

3.  Image quality assessment: from error visibility to structural similarity.

Authors:  Zhou Wang; Alan Conrad Bovik; Hamid Rahim Sheikh; Eero P Simoncelli
Journal:  IEEE Trans Image Process       Date:  2004-04       Impact factor: 10.856

4.  Comparison of ultrasonography, CT angiography, and digital subtraction angiography in severe carotid stenoses.

Authors:  R Herzig; S Burval; B Krupka; I Vlachová; K Urbánek; J Mares
Journal:  Eur J Neurol       Date:  2004-11       Impact factor: 6.089

5.  Three-Dimensional Volume Registration of Carotid MR Images.

Authors:  Baowei Fei; Jasjit S Suri; David L Wilson
Journal:  Stud Health Technol Inform       Date:  2005

6.  Image information and visual quality.

Authors:  Hamid Rahim Sheikh; Alan C Bovik
Journal:  IEEE Trans Image Process       Date:  2006-02       Impact factor: 10.856

Review 7.  2011 ASA/ACCF/AHA/AANN/AANS/ACR/ASNR/CNS/SAIP/SCAI/SIR/SNIS/SVM/SVS guideline on the management of patients with extracranial carotid and vertebral artery disease: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines, and the American Stroke Association, American Association of Neuroscience Nurses, American Association of Neurological Surgeons, American College of Radiology, American Society of Neuroradiology, Congress of Neurological Surgeons, Society of Atherosclerosis Imaging and Prevention, Society for Cardiovascular Angiography and Interventions, Society of Interventional Radiology, Society of NeuroInterventional Surgery, Society for Vascular Medicine, and Society for Vascular Surgery.

Authors:  Thomas G Brott; Jonathan L Halperin; Suhny Abbara; J Michael Bacharach; John D Barr; Ruth L Bush; Christopher U Cates; Mark A Creager; Susan B Fowler; Gary Friday; Vicki S Hertzberg; E Bruce McIff; Wesley S Moore; Peter D Panagos; Thomas S Riles; Robert H Rosenwasser; Allen J Taylor
Journal:  J Am Coll Cardiol       Date:  2011-02-01       Impact factor: 24.094

8.  Multimodality image registration by maximization of mutual information.

Authors:  F Maes; A Collignon; D Vandermeulen; G Marchal; P Suetens
Journal:  IEEE Trans Med Imaging       Date:  1997-04       Impact factor: 10.048

9.  Nonrigid registration of three-dimensional ultrasound and magnetic resonance images of the carotid arteries.

Authors:  Nuwan D Nanayakkara; Bernard Chiu; Abbas Samani; J David Spence; Jagath Samarabandu; Grace Parraga; Aaron Fenster
Journal:  Med Phys       Date:  2009-02       Impact factor: 4.071

10.  A "twisting and bending" model-based nonrigid image registration technique for 3-D ultrasound carotid images.

Authors:  Nuwan D Nanayakkara; Bernard Chiu; Abbas Samani; J David Spence; Jagath Samarabandu; Aaron Fenster
Journal:  IEEE Trans Med Imaging       Date:  2008-10       Impact factor: 10.048

View more
  3 in total

1.  A hybrid registration-based method for whole-body micro-CT mice images.

Authors:  Xiaochao Qu; Xueyuan Gao; Xianhui Xu; Shouping Zhu; Jimin Liang
Journal:  Med Biol Eng Comput       Date:  2015-09-21       Impact factor: 2.602

2.  Comparative evaluation of registration algorithms in different brain databases with varying difficulty: results and insights.

Authors:  Yangming Ou; Hamed Akbari; Michel Bilello; Xiao Da; Christos Davatzikos
Journal:  IEEE Trans Med Imaging       Date:  2014-06-13       Impact factor: 10.048

3.  Breast biopsy navigation system with an assisted needle holder tool and 2D graphical user interface.

Authors:  Jackrit Suthakorn; Narucha Tanaiutchawoot; Cholatip Wiratkapan; Songpol Ongwattanakul
Journal:  Eur J Radiol Open       Date:  2018-07-18
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.