Literature DB >> 11476929

Evaluation of voxel-based registration of 3-D power Doppler ultrasound and 3-D magnetic resonance angiographic images of carotid arteries.

P J Slomka1, J Mandel, D Downey, A Fenster.   

Abstract

Spatial registration and fusion of ultrasound (US) images with other modalities may aid clinical interpretation. We implemented and evaluated on patient data an automated retrospective registration of magnetic resonance angiography (MRA) carotid bifurcation images with 3-D power Doppler ultrasound (PD US) and indirectly with 3-D B-mode US. Volumes were initially thresholded to reduce the uncorrelated noise signals. The registration algorithm subsequently maximized the mutual information measure between the PD US and 3-D MRA via iterative simplex search to find best "rigid body" transformation. We rated the performance of the algorithm visually on (n = 5) clinical MRA and 3-D PD US datasets. We also evaluated quantitatively the effect of thresholding, initial misalignment of the paired volumes and the reproducibility registration. We investigated the effect of image artefacts by simulation experiments. Preregistration misalignments of up to 5 mm in the transaxial plane, up to 10 mm along the axis of the carotids and up to 40 degrees resulted in 107 of 110 successful registrations, with translational and rotational errors of 0.32 mm +/- 0.3 mm and 1.6 +/- 2.1 degrees. The algorithm was not affected by missing arterial segments of up to 8 mm in length. The average registration time was 4 min. We conclude that the algorithm could be applied to 3-D US PD and MRA data for automated multimodality registration of carotid vessels without the use of fiducials.

Entities:  

Mesh:

Year:  2001        PMID: 11476929     DOI: 10.1016/s0301-5629(01)00387-8

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  13 in total

1.  Interventional navigation for abdominal therapy based on simultaneous use of MRI and ultrasound.

Authors:  J Hong; H Nakashima; K Konishi; S Ieiri; K Tanoue; M Nakamuta; M Hashizume
Journal:  Med Biol Eng Comput       Date:  2006-11-11       Impact factor: 2.602

2.  Mutual-information-based image to patient re-registration using intraoperative ultrasound in image-guided neurosurgery.

Authors:  Songbai Ji; Ziji Wu; Alex Hartov; David W Roberts; Keith D Paulsen
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

3.  A hybrid framework for registration of carotid ultrasound images combining iconic and geometric features.

Authors:  Anupama Gupta; Harsh K Verma; Savita Gupta
Journal:  Med Biol Eng Comput       Date:  2013-05-25       Impact factor: 2.602

4.  Patient Registration Using Intraoperative Stereovision in Image-guided Open Spinal Surgery.

Authors:  Songbai Ji; Xiaoyao Fan; Keith D Paulsen; David W Roberts; Sohail K Mirza; S Scott Lollis
Journal:  IEEE Trans Biomed Eng       Date:  2015-03-26       Impact factor: 4.538

5.  Combining multiple true 3D ultrasound image volumes through re-registration and rasterization.

Authors:  Songbai Ji; David W Roberts; Alex Hartov; Keith D Paulsen
Journal:  Med Image Comput Comput Assist Interv       Date:  2009

6.  Intraoperative patient registration using volumetric true 3D ultrasound without fiducials.

Authors:  Songbai Ji; David W Roberts; Alex Hartov; Keith D Paulsen
Journal:  Med Phys       Date:  2012-12       Impact factor: 4.071

7.  The ultrasound brain helmet: new transducers and volume registration for in vivo simultaneous multi-transducer 3-D transcranial imaging.

Authors:  Brooks D Lindsey; Edward D Light; Heather A Nicoletto; Ellen R Bennett; Daniel T Laskowitz; Stephen W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-06       Impact factor: 2.725

8.  A neurosurgical navigation system based on intraoperative tumour remnant estimation.

Authors:  Jaesung Hong; Yoshihiro Muragaki; Ryoichi Nakamura; Makoto Hashizume; Hiroshi Iseki
Journal:  J Robot Surg       Date:  2007-02-10

9.  Coregistration of ultrasonography and magnetic resonance imaging with a preliminary investigation of the spatial colocalization of vascular endothelial growth factor receptor 2 expression and tumor perfusion in a murine tumor model.

Authors:  Mary E Loveless; Jennifer G Whisenant; Kevin Wilson; Andrej Lyshchik; Tuhin K Sinha; John C Gore; Thomas E Yankeelov
Journal:  Mol Imaging       Date:  2009 Jul-Aug       Impact factor: 4.488

10.  3D ultrasound-CT registration of the liver using combined landmark-intensity information.

Authors:  Thomas Lange; Nils Papenberg; Stefan Heldmann; Jan Modersitzki; Bernd Fischer; Hans Lamecker; Peter M Schlag
Journal:  Int J Comput Assist Radiol Surg       Date:  2008-10-19       Impact factor: 2.924

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.