Literature DB >> 23703899

Three-dimensional multidetector computed tomography versus conventional 2-dimensional transesophageal echocardiography for annular sizing in transcatheter aortic valve replacement: Influence on postprocedural paravalvular aortic regurgitation.

Nicolaj C Hansson1, Leif Thuesen, Vibeke E Hjortdal, Jonathon Leipsic, Henning R Andersen, Steen H Poulsen, John G Webb, Evald H Christiansen, Lars E Rasmussen, Lars R Krusell, Kim Terp, Kaj E Klaaborg, Mariann Tang, Jens F Lassen, Hans E Bøtker, Bjarne L Nørgaard.   

Abstract

OBJECTIVES: In transcatheter aortic valve replacement (TAVR), the influence of aortic annular assessment with either multidetector computed tomography (MDCT) or conventional transesophageal echocardiography (TEE) on the incidence of postprocedural paravalvular aortic regurgitation (PAR) was evaluated.
BACKGROUND: PAR remains a major limitation in TAVR. Appropriate selection of transcatheter heart valve (THV) size is crucial to prevent PAR.
METHODS: Outcomes following TAVR with a balloon-expandable THV were compared in two retrospective cohorts identified according to whether THV size selection was based on TEE (study group 1, n = 80) or MDCT (study group 2, n = 58).
RESULTS: The two study groups were comparable with regard to baseline clinical, risk score, and echocardiographic characteristics. The incidence of moderate/severe PAR was lower in study group 2 than in group 1, 8.6% versus 28.8% (P < 0.01). The difference between the THV nominal diameter and MDCT annular diameter was predictive of moderate/severe PAR (AUC 0.84; 95% CI: 0.72-0.92). Neither age, gender, body mass index, annular eccentricity index, aortic valve calcification nor the difference between the THV diameter and the TEE annular diameter predicted postprocedural PAR. Increased THV oversizing relative to the MDCT mean annular diameter was associated with reduced severity of PAR. No difference in perprocedural complications between two study groups was observed.
CONCLUSION: MDCT-based annular sizing in TAVR significantly reduces postprocedural PAR, and THV oversizing appears pivotal in this aspect. Further delineation of the optimal degree of THV oversizing is needed.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  Transcatheter aortic valve replacement; aortic annulus; computed tomography; echocardiography; paravalvular regurgitation; valve sizing

Mesh:

Year:  2013        PMID: 23703899     DOI: 10.1002/ccd.25005

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  10 in total

Review 1.  DNA transposons in vertebrate functional genomics.

Authors:  C Miskey; Z Izsvák; K Kawakami; Z Ivics
Journal:  Cell Mol Life Sci       Date:  2005-03       Impact factor: 9.261

Review 2.  [Aortic valve stenosis: computed tomography prior to transcatheter aortic valve implantation (TAVI). How can the outcome be improved?].

Authors:  M Hell; S Achenbach; M Arnold
Journal:  Herz       Date:  2015-06       Impact factor: 1.443

3.  Multi-parametric approach to predict prosthetic valve size using CMR and clinical data: insights from SAVR.

Authors:  Federico E Mordini; Conor F Hynes; Richard L Amdur; Jeffrey Panting; Dominic A Emerson; Jason Morrissette; Erin Goheen-Thomas; Michael D Greenberg; Gregory D Trachiotis
Journal:  Int J Cardiovasc Imaging       Date:  2021-03-10       Impact factor: 2.357

Review 4.  Role of Imaging in Transcatheter Aortic Valve Replacement.

Authors:  Corinna Storz; Tobias Geisler; Mike Notohamiprodjo; Konstantin Nikolaou; Fabian Bamberg
Journal:  Curr Treat Options Cardiovasc Med       Date:  2016-10

Review 5.  On the Mechanics of Transcatheter Aortic Valve Replacement.

Authors:  Lakshmi P Dasi; Hoda Hatoum; Arash Kheradvar; Ramin Zareian; S Hamed Alavi; Wei Sun; Caitlin Martin; Thuy Pham; Qian Wang; Prem A Midha; Vrishank Raghav; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2016-11-21       Impact factor: 3.934

Review 6.  Preoperative TAVR Planning: How to Do It.

Authors:  Rodrigo Petersen Saadi; Ana Paula Tagliari; Eduardo Keller Saadi; Marcelo Haertel Miglioranza; Carisi Anne Polanczyck
Journal:  J Clin Med       Date:  2022-05-05       Impact factor: 4.964

7.  Calcification Characteristics of Low-Flow Low-Gradient Severe Aortic Stenosis in Patients Undergoing Transcatheter Aortic Valve Replacement.

Authors:  Barbara E Stähli; Thi Dan Linh Nguyen-Kim; Cathérine Gebhard; Thomas Frauenfelder; Felix C Tanner; Fabian Nietlispach; Francesco Maisano; Volkmar Falk; Thomas F Lüscher; Willibald Maier; Ronald K Binder
Journal:  Cardiol Res Pract       Date:  2015-09-07       Impact factor: 1.866

8.  Imaging in Transcatheter Aortic Valve Replacement (TAVR): role of the radiologist.

Authors:  Diana E Litmanovich; Eduard Ghersin; David A Burke; Jeffrey Popma; Maryam Shahrzad; Alexander A Bankier
Journal:  Insights Imaging       Date:  2014-01-21

9.  Risk factors for paravalvular leak after transcatheter aortic valve implantation.

Authors:  Krzysztof Wilczek; Kamil Bujak; Rafał Reguła; Piotr Chodór; Tadeusz Osadnik
Journal:  Kardiochir Torakochirurgia Pol       Date:  2015-06-30

10.  Comparison of postoperative outcomes following multidetector computed tomography based vs transesophageal echocardiography based annulus sizing for transcatheter aortic valve replacement: A systematic review and meta-analysis.

Authors:  Guozhang Tang; Qifeng Lv; Xiangqin He
Journal:  Echocardiography       Date:  2020-09-23       Impact factor: 1.724

  10 in total