Literature DB >> 27566706

Role of Imaging in Transcatheter Aortic Valve Replacement.

Corinna Storz1, Tobias Geisler2, Mike Notohamiprodjo1, Konstantin Nikolaou1, Fabian Bamberg3.   

Abstract

OPINION STATEMENT: Transcatheter aortic valve replacement (TAVR) has emerged as an effective treatment alternative in patients with severe aortic stenosis (AS) who are deemed surgically high-risk or ineligible for surgery. Pre-procedural imaging, in particular computed tomography (CT), plays an integral part in the planning and performance of TAVR and is crucial for a successful treatment. Novel technological advances in CT include high-pitch, low kV acquisitions, and iterative reconstruction resulting in high image quality at substantially reduced scan duration, contrast volume, and radiation exposure. Given the high spatial and temporal resolution of the acquisitions, CT angiography provides critical information on the eligibility for the peripheral vascular access, aortic root assessment, as well as the aortic annulus measurements, including the coronary ostia and concomitant cardiac pathology. Pre-procedural CT imaging is key for appropriate device size selection to minimize peri-procedural complications and optimize procedural success. In this article, we review the current state of imaging in the pre-interventional setting of TAVR with a special emphasis on CT.

Entities:  

Keywords:  Aortic stenosis; Computed tomography; Transcatheter aortic valve implantation (TAVI); Transcatheter aortic valve replacement (TAVR)

Year:  2016        PMID: 27566706     DOI: 10.1007/s11936-016-0482-6

Source DB:  PubMed          Journal:  Curr Treat Options Cardiovasc Med        ISSN: 1092-8464


  51 in total

1.  Aortic annulus diameter determination by multidetector computed tomography: reproducibility, applicability, and implications for transcatheter aortic valve implantation.

Authors:  Ronen Gurvitch; John G Webb; Ren Yuan; Mark Johnson; Cameron Hague; Alexander B Willson; Stefan Toggweiler; David A Wood; Jian Ye; Robert Moss; Christopher R Thompson; Stephan Achenbach; James K Min; Troy M Labounty; Ricardo Cury; Jonathon Leipsic
Journal:  JACC Cardiovasc Interv       Date:  2011-11       Impact factor: 11.195

2.  Multislice computed tomography for prediction of optimal angiographic deployment projections during transcatheter aortic valve implantation.

Authors:  Ronen Gurvitch; David A Wood; Jonathon Leipsic; Edgar Tay; Mark Johnson; Jian Ye; Fabian Nietlispach; Namal Wijesinghe; Anson Cheung; John G Webb
Journal:  JACC Cardiovasc Interv       Date:  2010-11       Impact factor: 11.195

3.  3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis.

Authors:  Alexander B Willson; John G Webb; Troy M Labounty; Stephan Achenbach; Robert Moss; Miriam Wheeler; Christopher Thompson; James K Min; Ronen Gurvitch; Bjarne L Norgaard; Cameron J Hague; Stefan Toggweiler; Ronald Binder; Melanie Freeman; Rohan Poulter; Steen Poulsen; David A Wood; Jonathon Leipsic
Journal:  J Am Coll Cardiol       Date:  2012-02-22       Impact factor: 24.094

4.  Interobserver variability of CT angiography for evaluation of aortic annulus dimensions prior to transcatheter aortic valve implantation (TAVI).

Authors:  C Schmidkonz; M Marwan; L Klinghammer; M Mitschke; A Schuhbaeck; M Arnold; M Lell; S Achenbach; T Pflederer
Journal:  Eur J Radiol       Date:  2014-06-19       Impact factor: 3.528

5.  5-year outcomes of transcatheter aortic valve replacement compared with standard treatment for patients with inoperable aortic stenosis (PARTNER 1): a randomised controlled trial.

Authors:  Samir R Kapadia; Martin B Leon; Raj R Makkar; E Murat Tuzcu; Lars G Svensson; Susheel Kodali; John G Webb; Michael J Mack; Pamela S Douglas; Vinod H Thourani; Vasilis C Babaliaros; Howard C Herrmann; Wilson Y Szeto; Augusto D Pichard; Mathew R Williams; Gregory P Fontana; D Craig Miller; William N Anderson; Jodi J Akin; Michael J Davidson; Craig R Smith
Journal:  Lancet       Date:  2015-03-15       Impact factor: 79.321

6.  Prediction of optimal deployment projection for transcatheter aortic valve replacement: angiographic 3-dimensional reconstruction of the aortic root versus multidetector computed tomography.

Authors:  Ronald K Binder; Jonathon Leipsic; David Wood; Teri Moore; Stefan Toggweiler; Alex Willson; Ronen Gurvitch; Melanie Freeman; John G Webb
Journal:  Circ Cardiovasc Interv       Date:  2012-03-20       Impact factor: 6.546

7.  Percutaneous aortic valve replacement: vascular outcomes with a fully percutaneous procedure.

Authors:  Stefan Toggweiler; Ronen Gurvitch; Jonathon Leipsic; David A Wood; Alexander B Willson; Ronald K Binder; Anson Cheung; Jian Ye; John G Webb
Journal:  J Am Coll Cardiol       Date:  2012-01-10       Impact factor: 24.094

8.  The impact of integration of a multidetector computed tomography annulus area sizing algorithm on outcomes of transcatheter aortic valve replacement: a prospective, multicenter, controlled trial.

Authors:  Ronald K Binder; John G Webb; Alexander B Willson; Marina Urena; Nicolaj C Hansson; Bjarne L Norgaard; Philippe Pibarot; Marco Barbanti; Eric Larose; Melanie Freeman; Eric Dumont; Chris Thompson; Miriam Wheeler; Robert R Moss; Tae-hyun Yang; Sergio Pasian; Cameron J Hague; Giang Nguyen; Rekha Raju; Stefan Toggweiler; James K Min; David A Wood; Josep Rodés-Cabau; Jonathon Leipsic
Journal:  J Am Coll Cardiol       Date:  2013-05-15       Impact factor: 24.094

9.  Effective diameter of the aortic annulus prior to transcatheter aortic valve implantation: influence of area-based versus perimeter-based calculation.

Authors:  K von Aspern; B Foldyna; C D Etz; A Hoyer; F Girrbach; D Holzhey; C Lücke; M Grothoff; A Linke; F W Mohr; M Gutberlet; L Lehmkuhl
Journal:  Int J Cardiovasc Imaging       Date:  2014-08-28       Impact factor: 2.357

10.  MDCT evaluation of aortic root and aortic valve prior to TAVI. What is the optimal imaging time point in the cardiac cycle?

Authors:  Tomas Jurencak; Jakub Turek; Bastiaan L J H Kietselaer; Casper Mihl; Madeleine Kok; Vincent G V A van Ommen; Leen A F M van Garsse; Estelle C Nijssen; Joachim E Wildberger; Marco Das
Journal:  Eur Radiol       Date:  2015-02-24       Impact factor: 5.315

View more
  5 in total

Review 1.  Standard imaging techniques in transcatheter aortic valve replacement.

Authors:  Arash Salemi; Berhane M Worku
Journal:  J Thorac Dis       Date:  2017-04       Impact factor: 2.895

2.  Ferumoxytol MRA for transcatheter aortic valve replacement planning with renal insufficiency.

Authors:  Kimberly Kallianos; Travis S Henry; Yerem Yeghiazarians; Jeffrey Zimmet; Kendrick A Shunk; Elaine E Tseng; Vaikom Mahadevan; Michael D Hope
Journal:  Int J Cardiol       Date:  2016-12-30       Impact factor: 4.164

3.  Pre-procedural CT angiography inferior vena cava measurements: a predictor of mortality in patients undergoing transcatheter aortic valve implantation.

Authors:  Matthias Eberhard; Gianluca Milanese; Michael Ho; Stefan Zimmermann; Thomas Frauenfelder; Fabian Nietlispach; Francesco Maisano; Felix C Tanner; Thi Dan Linh Nguyen-Kim
Journal:  Eur Radiol       Date:  2018-07-17       Impact factor: 5.315

Review 4.  The role of echocardiography and CT angiography in transcatheter aortic valve implantation patients.

Authors:  Emmanouil Chourdakis; Ioanna Koniari; Nicholas G Kounis; Dimitrios Velissaris; Nikolaos Koutsogiannis; Grigorios Tsigkas; Karl Eugen Hauptmann; Bruno Sontag; George Hahalis
Journal:  J Geriatr Cardiol       Date:  2018-01       Impact factor: 3.327

5.  Incidental Findings Diagnosed during Preprocedural Evaluation of TAVR.

Authors:  Levent Sahiner; Cem Coteli; Ahmet Kivrak; Yusuf Ziya Sener; Serkan Asil; Tuncay Hazirolan; Ergun Baris Kaya; Necla Ozer; Kudret Aytemir
Journal:  Cardiol Res Pract       Date:  2019-04-02       Impact factor: 1.866