First-in-man implantation of leadless ultrasound-based cardiac stimulation pacing system: novel endocardial left ventricular resynchronization therapy in heart failure patients.

Angelo Auricchio1, Peter-Paul Delnoy, François Regoli, Martin Seifert, Thanasie Markou, Christian Butter.   

Abstract

AIMS: The importance of specific-site pacing is increasingly recognized in cardiac resynchronization therapy (CRT). Using current pacing technology, site selection is still largely limited by coronary vein anatomy, whereas left ventricular (LV) endocardial pacing using current lead technology is risky and challenging. To overcome limitations and complications with current LV pacing, the feasibility of a new technology enabling LV endocardial stimulation without the use of a lead is being evaluated in patients. METHODS AND
RESULTS: Patients presented in this report are part of the Wireless Stimulation Endocardially for CRT Trial (WiSE-CRT) study investigating the safety and performance of the WiCS(®)-LV system, an implantable cardiac pacing system capable of leadless pacing based on converting ultrasound energy to electrical energy. Three patients are presented: (i) a patient with an existing implantable defibrillator, (ii) a patient with a CRT system whose LV lead does not capture, and (iii) a CRT patient classified as a non-responder. All three patients were successfully treated. Acute electrical pacing thresholds ranged from 0.7 to 1.0 V at 0.5 ms; all patients retained captured at 6 months. Functional New York Heart Association class significantly changed (Pre: III in two patients, and IV in one patient; Post: I in one patient, II in one patient, and II-III in one patient), and LV ejection fraction increased from 23.7 ± 3.4% to 39 ± 6.2% (P < 0.017).
CONCLUSION: This report on three first-in-man cases shows that leadless endocardial pacing may be safely applied and effective, conferring short- to-mid-term symptomatic benefits. These promising findings are yet to be substantiated by larger ongoing studies. CLINICAL TRIAL REGISTRATION INFORMATION: http://clinicaltrials.gov/ct2/show/NCT01294527.

Entities:  

Keywords:  Cardiac pacing; Cardiac resynchronization therapy; Heart failure; Left ventricle; Outcome

Mesh:

Year:  2013        PMID: 23703364     DOI: 10.1093/europace/eut124

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  23 in total

Review 1.  Tricuspid valve incompetence following implantation of ventricular leads.

Authors:  Giselle A Baquero; Jerry Luck; Gerald V Naccarelli; Mario D Gonzalez; Javier E Banchs
Journal:  Curr Heart Fail Rep       Date:  2015-04

Review 2.  Novel Pacing Strategies for Heart Failure Management.

Authors:  Jordan S Leyton-Mange; Theofanie Mela
Journal:  Curr Treat Options Cardiovasc Med       Date:  2017-08

Review 3.  [Leadless endocardial ultrasound based left ventricular stimulation : WISE CRT System: alternative to conventional methods].

Authors:  C Butter; S Fehrendt; V Möller; M Seifert
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2018-11-08

4.  Cardiac resynchronization therapy update: evolving indications, expanding benefit?

Authors:  C Butcher; Y Mareev; V Markides; M Mason; T Wong; J G F Cleland
Journal:  Curr Cardiol Rep       Date:  2015-10       Impact factor: 2.931

Review 5.  Leadless Cardiac Devices-Pacemakers and Implantable Cardioverter-Defibrillators.

Authors:  Hans Rutzen-Lopez; Jose Silva; Robert H Helm
Journal:  Curr Treat Options Cardiovasc Med       Date:  2016-08

6.  Atrial autonomic denervation for the treatment of long-standing symptomatic sinus bradycardia in non-elderly patients.

Authors:  Liang Zhao; Weifeng Jiang; Li Zhou; Yuanlong Wang; Xiaodong Zhang; Shaohui Wu; Kai Xu; Xu Liu
Journal:  J Interv Card Electrophysiol       Date:  2015-02-19       Impact factor: 1.900

Review 7.  Leadless Cardiac Pacemakers: Pacing Paradigm Change.

Authors:  Petr Neuzil; Vivek Y Reddy
Journal:  Curr Cardiol Rep       Date:  2015-08       Impact factor: 2.931

8.  Wireless Pacing Using an Asynchronous Three-Tiered Inductive Power Transfer System.

Authors:  Parinaz Abiri; Arash Abiri; Varun Gudapati; Chih-Chiang Chang; Mehrdad Roustaei; Hamed Bourenane; Usama Anwar; Dejan Markovic; Tzung K Hsiai
Journal:  Ann Biomed Eng       Date:  2020-01-23       Impact factor: 3.934

Review 9.  Cardiac strangulation from epicardial pacemaker leads: diagnosis, treatment, and prevention.

Authors:  Daiji Takeuchi; Yasuko Tomizawa
Journal:  Gen Thorac Cardiovasc Surg       Date:  2014-10-11

10.  Developments in Cardiac Resynchronisation Therapy.

Authors:  Geoffrey F Lewis; Michael R Gold
Journal:  Arrhythm Electrophysiol Rev       Date:  2015-08
View more