Literature DB >> 2368953

Evaluation of two applanation tonometers in horses.

P E Miller1, J P Pickett, L J Majors.   

Abstract

Comparisons were made of measurements obtained in horses, using 2 applanation tonometers in vivo and in vitro. In vitro comparisons indicated that although neither instrument accurately recorded intraocular pressure (IOP), compared with manometric measurements, results of both instruments indicated linear digression from manometric IOP values that could readily be corrected, thereby accurately estimating IOP in horses. For tonometer 1 (MacKay-Marg), calculated actual IOP = 1.48 - 0.9 mm of Hg; and for tonometer 2 (Tono-Pen), calculated actual IOP = 1.38 + 2.3 mm of Hg. The coefficients of determination (r2) values were markedly high (0.99 for both equations). In vivo comparisons in clinically normal horses did not reveal significant differences in measured IOP between the 2 instruments, and IOP was not altered from baseline after auriculopalpebral nerve block. Mean (+/- SD) IOP in clinically normal horses was 23.5 +/- 6.10 mm of Hg and 23.3 +/- 6.89 mm of Hg, for tonometers 1 and 2, respectively.

Entities:  

Mesh:

Year:  1990        PMID: 2368953

Source DB:  PubMed          Journal:  Am J Vet Res        ISSN: 0002-9645            Impact factor:   1.156


  7 in total

1.  Intraocular pressure measurements in cattle, sheep, and goats with 2 different types of tonometers.

Authors:  Nina Peche; Johanna Corinna Eule
Journal:  Can J Vet Res       Date:  2018-07       Impact factor: 1.310

2.  Evaluation of the Perkins handheld applanation tonometer in horses and cattle.

Authors:  Silvia Franco Andrade; Daniel Silva Kupper; Luiz Fernando Rodrigues Pinho; Elizabeth Cunha Franco; Marcus Vinícius Felix Fabri Prataviera; Rodrigo Rolim Duarte; José Ricardo Cecílio Junqueira
Journal:  J Vet Sci       Date:  2011-06       Impact factor: 1.672

3.  Validation of the TonoVet® rebound tonometer in normal and glaucomatous cats.

Authors:  Gillian J McLellan; Jeremy P Kemmerling; Julie A Kiland
Journal:  Vet Ophthalmol       Date:  2012-06-06       Impact factor: 1.644

4.  The location of sites and effect of semiconductor diode trans-scleral cyclophotocoagulation on the buphthalmic equine globe.

Authors:  Anne J Gemensky-Metzler; David A Wilkie; Steven E Weisbrode; Sonia E Kuhn
Journal:  Vet Ophthalmol       Date:  2014-04-03       Impact factor: 1.644

5.  Validation and comparison of four handheld tonometers in normal ex vivo canine eyes.

Authors:  Andrea L Minella; Julie A Kiland; Shawna Gloe; Gillian J McLellan
Journal:  Vet Ophthalmol       Date:  2020-06-01       Impact factor: 1.644

6.  Comparison of two rebound tonometers in healthy horses.

Authors:  Minna P Mustikka; Elina M Pietilä; Anna K Mykkänen; Thomas S C Grönthal
Journal:  Vet Ophthalmol       Date:  2020-09-04       Impact factor: 1.644

7.  Retinal detachment secondary to vitreoretinopathy in two closely related warmblood horses.

Authors:  Eline Vercruysse; Carolina Naranjo; Aurélie Sauvage; Maxime Vandersmissen; Magda Grauwels; Sébastien Monclin
Journal:  Open Vet J       Date:  2021-11-19
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.