Literature DB >> 23681116

Dosimetric accuracy assessment of a treatment plan verification system for scanned proton beam radiotherapy: one-year experimental results and Monte Carlo analysis of the involved uncertainties.

S Molinelli1, A Mairani, A Mirandola, G Vilches Freixas, T Tessonnier, S Giordanengo, K Parodi, M Ciocca, R Orecchia.   

Abstract

During one year of clinical activity at the Italian National Center for Oncological Hadron Therapy 31 patients were treated with actively scanned proton beams. Results of patient-specific quality assurance procedures are presented here which assess the accuracy of a three-dimensional dose verification technique with the simultaneous use of multiple small-volume ionization chambers. To investigate critical cases of major deviations between treatment planning system (TPS) calculated and measured data points, a Monte Carlo (MC) simulation tool was implemented for plan verification in water. Starting from MC results, the impact of dose calculation, dose delivery and measurement set-up uncertainties on plan verification results was analyzed. All resulting patient-specific quality checks were within the acceptance threshold, which was set at 5% for both mean deviation between measured and calculated doses and standard deviation. The mean deviation between TPS dose calculation and measurement was less than ±3% in 86% of the cases. When all three sources of uncertainty were accounted for, simulated data sets showed a high level of agreement, with mean and maximum absolute deviation lower than 2.5% and 5%, respectively.

Entities:  

Mesh:

Year:  2013        PMID: 23681116     DOI: 10.1088/0031-9155/58/11/3837

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  11 in total

1.  Re-irradiation With Carbon Ion Radiotherapy for Pelvic Rectal Cancer Recurrences in Patients Previously Irradiated to the Pelvis.

Authors:  Amelia Barcellini; Viviana Vitolo; Lorenzo Cobianchi; Andrea Peloso; Alessandro Vanoli; Alfredo Mirandola; Angelica Facoetti; Maria Rosaria Fiore; Alberto Iannalfi; Barbara Vischioni; Francesco Cuccia; Sara Ronchi; Maria Bonora; Giulia Riva; Rachele Petrucci; Emma D'Ippolito; Francesca Dal Mas; Lorenzo Preda; Francesca Valvo
Journal:  In Vivo       Date:  2020 May-Jun       Impact factor: 2.155

2.  Patient-Specific QA of Spot-Scanning Proton Beams using Radiochromic Film.

Authors:  Maria F Chan; Chin-Cheng Chen; Chengyu Shi; Jingdong Li; Xiaoli Tang; Xiang Li; Dennis Mah
Journal:  Int J Med Phys Clin Eng Radiat Oncol       Date:  2017-05-16

3.  Characterization of a MLIC Detector for QA in Scanned Proton and Carbon Ion Beams.

Authors:  Alessandro Vai; Alfredo Mirandola; Giuseppe Magro; Davide Maestri; Edoardo Mastella; Andrea Mairani; Silvia Molinelli; Stefania Russo; Michele Togno; Sara La Civita; Mario Ciocca
Journal:  Int J Part Ther       Date:  2019-11-26

4.  Monte Carlo-based parametrization of the lateral dose spread for clinical treatment planning of scanned proton and carbon ion beams.

Authors:  Katia Parodi; Andrea Mairani; Florian Sommerer
Journal:  J Radiat Res       Date:  2013-07       Impact factor: 2.724

5.  The FLUKA Code: An Accurate Simulation Tool for Particle Therapy.

Authors:  Giuseppe Battistoni; Julia Bauer; Till T Boehlen; Francesco Cerutti; Mary P W Chin; Ricardo Dos Santos Augusto; Alfredo Ferrari; Pablo G Ortega; Wioletta Kozłowska; Giuseppe Magro; Andrea Mairani; Katia Parodi; Paola R Sala; Philippe Schoofs; Thomas Tessonnier; Vasilis Vlachoudis
Journal:  Front Oncol       Date:  2016-05-11       Impact factor: 6.244

Review 6.  Range Verification Methods in Particle Therapy: Underlying Physics and Monte Carlo Modeling.

Authors:  Aafke Christine Kraan
Journal:  Front Oncol       Date:  2015-07-07       Impact factor: 6.244

7.  Monte Carlo Calculations Supporting Patient Plan Verification in Proton Therapy.

Authors:  Thiago V M Lima; Manjit Dosanjh; Alfredo Ferrari; Silvia Molineli; Mario Ciocca; Andrea Mairani
Journal:  Front Oncol       Date:  2016-03-18       Impact factor: 6.244

8.  Phase Space Generation for Proton and Carbon Ion Beams for External Users' Applications at the Heidelberg Ion Therapy Center.

Authors:  Thomas Tessonnier; Tiago Marcelos; Andrea Mairani; Stephan Brons; Katia Parodi
Journal:  Front Oncol       Date:  2016-01-11       Impact factor: 6.244

9.  Fast robust dose calculation on GPU for high-precision 1H, 4He, 12C and 16O ion therapy: the FRoG platform.

Authors:  Stewart Mein; Kyungdon Choi; Benedikt Kopp; Thomas Tessonnier; Julia Bauer; Alfredo Ferrari; Thomas Haberer; Jürgen Debus; Amir Abdollahi; Andrea Mairani
Journal:  Sci Rep       Date:  2018-10-04       Impact factor: 4.379

10.  FRoG-A New Calculation Engine for Clinical Investigations with Proton and Carbon Ion Beams at CNAO.

Authors:  KyungDon Choi; Stewart B Mein; Benedikt Kopp; Giuseppe Magro; Silvia Molinelli; Mario Ciocca; Andrea Mairani
Journal:  Cancers (Basel)       Date:  2018-10-23       Impact factor: 6.639

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.