Literature DB >> 23680427

The effects of walking speed and prosthetic ankle adapters on upper extremity dynamics and stability-related parameters in bilateral transtibial amputee gait.

Matthew J Major1, Rebecca L Stine, Steven A Gard.   

Abstract

Bilateral transtibial amputee (BTA) gait has been investigated less and is not as well understood compared to that of their unilateral counterparts. Relative to able-bodied individuals, BTAs walk with reduced self-selected speeds, increased step width, hip-hiking, and greater metabolic cost. The clinically observed upper body motions of these individuals have not been quantified, but appear substantially different from able-bodied ambulators and may impact upright balance. Therefore, the objective of this study was to characterize the upper extremity kinematics of BTAs during steady-state walking. We measured medial-lateral ground reaction forces, step width and extrapolated center-of-mass (XCoM) trajectory, and observed effects of walking speed and increased prosthetic ankle range-of-motion (ROM) on these parameters. Significantly, BTAs display greater lateral trunk flexion ROM and shoulder abduction than able-bodied individuals when walking at similar speeds, and the inclusion of prosthetic adaptors for increasing passive ankle ROM slightly reduced step width. Overall, exaggerated lateral trunk flexion ROM was invariant with step width. Results suggest that lateral trunk motion is useful for shifting the body center-of-mass laterally onto the leading stance limb while simultaneously unloading the trailing limb. However, exaggerated lateral trunk flexion may introduce an unstable scenario if the XCoM is displaced beyond the lateral base-of-support. Further studies would be useful to identify if either prostheses that assist limb advancement and/or gait training may be effective in reducing this lateral sway while still maintaining efficient ambulation.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Bilateral; Center-of-mass; Gait; Transtibial amputation; Trunk

Mesh:

Year:  2013        PMID: 23680427      PMCID: PMC3778081          DOI: 10.1016/j.gaitpost.2013.04.012

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  27 in total

1.  A preliminary investigation of pelvic obliquity patterns during gait in persons with transtibial and transfemoral amputation.

Authors:  S B Michaud; S A Gard; D S Childress
Journal:  J Rehabil Res Dev       Date:  2000 Jan-Feb

2.  Postural sway and active balance performance in highly active lower-limb amputees.

Authors:  John G Buckley; Dan O'Driscoll; Simon J Bennett
Journal:  Am J Phys Med Rehabil       Date:  2002-01       Impact factor: 2.159

3.  Measurement of lower extremity kinematics during level walking.

Authors:  M P Kadaba; H K Ramakrishnan; M E Wootten
Journal:  J Orthop Res       Date:  1990-05       Impact factor: 3.494

4.  Energy expenditure in below-knee amputees: correlation with stump length.

Authors:  E G Gonzalez; P J Corcoran; R L Reyes
Journal:  Arch Phys Med Rehabil       Date:  1974-03       Impact factor: 3.966

5.  The prevalence and risk factors of falling and fear of falling among lower extremity amputees.

Authors:  W C Miller; M Speechley; B Deathe
Journal:  Arch Phys Med Rehabil       Date:  2001-08       Impact factor: 3.966

6.  Effect of prosthetic ankle units on roll-over shape characteristics during walking in persons with bilateral transtibial amputations.

Authors:  Steven A Gard; Po-Fu Su; Robert D Lipschutz; Andrew H Hansen
Journal:  J Rehabil Res Dev       Date:  2011

7.  Balance confidence among people with lower-limb amputations.

Authors:  William C Miller; Mark Speechley; A Barry Deathe
Journal:  Phys Ther       Date:  2002-09

8.  Oxygen consumption of elderly persons with bilateral below knee amputations: ambulation vs wheelchair propulsion.

Authors:  L L DuBow; P L Witt; M P Kadaba; R Reyes; V Cochran
Journal:  Arch Phys Med Rehabil       Date:  1983-06       Impact factor: 3.966

9.  Comparative study of the strength of the flexor and extensor muscles of the knee through isokinetic evaluation in normal subjects and patients subjected to trans-tibial amputation.

Authors:  A Pedrinelli; M Saito; R F Coelho; R B V Fontes; R Guarniero
Journal:  Prosthet Orthot Int       Date:  2002-12       Impact factor: 1.895

10.  Outcomes after trans-tibial amputation: the relationship between quiet stance ability, strength of hip abductor muscles and gait.

Authors:  Heidi Nadollek; Sandra Brauer; Rosemary Isles
Journal:  Physiother Res Int       Date:  2002
View more
  8 in total

1.  Considering passive mechanical properties and patient user motor performance in lower limb prosthesis design optimization to enhance rehabilitation outcomes.

Authors:  Matthew J Major; Nicholas P Fey
Journal:  Phys Ther Rev       Date:  2017-07-17

2.  The feasibility and validity of a wearable sensor system to assess the stability of high-functioning lower-limb prosthesis users.

Authors:  Kyle T Miller; Molly Russell; Terese Jenks; Kaddie Surratt; Kelly Poretti; Samantha S Eigenbrot; Jonathan S Akins; Matthew J Major
Journal:  J Prosthet Orthot       Date:  2020-08-11

3.  Exercise intervention for unilateral amputees with low back pain: study protocol for a randomised, controlled trial.

Authors:  Joseph G Wasser; Daniel C Herman; MaryBeth Horodyski; Jason L Zaremski; Brady Tripp; Phillip Page; Kevin R Vincent; Heather K Vincent
Journal:  Trials       Date:  2017-12-29       Impact factor: 2.279

4.  Step-to-Step Ankle Inversion/Eversion Torque Modulation Can Reduce Effort Associated with Balance.

Authors:  Myunghee Kim; Steven H Collins
Journal:  Front Neurorobot       Date:  2017-11-14       Impact factor: 2.650

5.  Biomechanical evaluation over level ground walking of user-specific prosthetic feet designed using the lower leg trajectory error framework.

Authors:  Victor Prost; W Brett Johnson; Jenny A Kent; Matthew J Major; Amos G Winter
Journal:  Sci Rep       Date:  2022-03-29       Impact factor: 4.379

6.  Focusing research efforts on the unique needs of women prosthesis users.

Authors:  Matthew J Major; Andrew H Hansen; Elizabeth Russell Esposito
Journal:  J Prosthet Orthot       Date:  2021-01-08

7.  Use of the margin of stability to quantify stability in pathologic gait - a qualitative systematic review.

Authors:  Fraje Watson; Peter C Fino; Matthew Thornton; Constantinos Heracleous; Rui Loureiro; Julian J H Leong
Journal:  BMC Musculoskelet Disord       Date:  2021-06-28       Impact factor: 2.362

8.  Proactive Locomotor Adjustments Are Specific to Perturbation Uncertainty in Below-Knee Prosthesis Users.

Authors:  Matthew J Major; Chelsi K Serba; Xinlin Chen; Nicholas Reimold; Franklyn Ndubuisi-Obi; Keith E Gordon
Journal:  Sci Rep       Date:  2018-01-30       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.