Literature DB >> 23670747

Real-time near-infrared fluorescent cholangiography could shorten operative time during robotic single-site cholecystectomy.

Nicolas C Buchs1, François Pugin, Dan E Azagury, Minoa Jung, Francesco Volonte, Monika E Hagen, Philippe Morel.   

Abstract

BACKGROUND: With the introduction of a new platform, robotic single-site cholecystectomy (RSSC) has been reported as feasible and safe for selected cases. In parallel, the development of real-time near-infrared fluorescent cholangiography using indocyanine green (ICG) has been seen as a help during the dissection, even if the data are still preliminary. The study purpose is to report our experience with ICG RSSC and compare the outcomes to standard RSSC.
METHODS: From February 2011 to December 2011, 44 selected patients underwent RSSC for symptomatic cholelithiasis. Among them, 23 (52.3%) were included in an experimental protocol using the ICG, and the remainder (47.7%) underwent standard RSSC. There was no randomization. The endpoints were the perioperative outcomes. This is a prospective study, approved by our local Ethics Committee.
RESULTS: There were no differences in terms of patients' characteristics, except that there were more male patients in the ICG group (47.8 vs. 9.5%; p = 0.008). Regarding the surgical data, the overall operative time was shorter for the ICG group, especially for patients with a body mass index (BMI) ≤25 (-24 min) but without reaching statistical significance (p = 0.06). For BMI >25, no differences were observed. Otherwise, there were no differences in terms of conversion, complications, or length of stay between both groups.
CONCLUSIONS: A RSSC with a real-time near-infrared fluorescent cholangiography can be performed safely. In addition, for selected patients with a low BMI, ICG could shorten the operative time during RSSC. Larger studies are still required before drawing definitive conclusions.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23670747     DOI: 10.1007/s00464-013-3005-5

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  24 in total

1.  First human surgery with a novel single-port robotic system: cholecystectomy using the da Vinci Single-Site platform.

Authors:  Matthew Kroh; Kevin El-Hayek; Steven Rosenblatt; Bipan Chand; Pedro Escobar; Jihad Kaouk; Sricharan Chalikonda
Journal:  Surg Endosc       Date:  2011-06-03       Impact factor: 4.584

2.  Overcoming the challenges of single-incision cholecystectomy with robotic single-site technology.

Authors:  Andrea Pietrabissa; Fabio Sbrana; Luca Morelli; Francesco Badessi; Luigi Pugliese; Alessio Vinci; Catherine Klersy; Giuseppe Spinoglio
Journal:  Arch Surg       Date:  2012-08

Review 3.  Robotic laparoendoscopy single site surgery: a transdisciplinary review.

Authors:  Alexandre Balaphas; Monika E Hagen; Nicolas C Buchs; François Pugin; Francesco Volonté; Ihsan Inan; Philippe Morel
Journal:  Int J Med Robot       Date:  2012-06-19       Impact factor: 2.547

4.  Single port access laparoscopic cholecystectomy (with video).

Authors:  Pascal Bucher; François Pugin; Nicolas Buchs; Sandrine Ostermann; Fadi Charara; Philippe Morel
Journal:  World J Surg       Date:  2009-05       Impact factor: 3.352

5.  Docking of the da Vinci Si Surgical System® with single-site technology.

Authors:  Pouya Iranmanesh; Philippe Morel; Nicolas C Buchs; François Pugin; Francesco Volonte; Usha Seshadri Kreaden; Monika E Hagen
Journal:  Int J Med Robot       Date:  2013-01-25       Impact factor: 2.547

6.  Anaphylactoid reactions after indocyanine-green administration.

Authors:  R Speich; B Saesseli; U Hoffmann; K A Neftel; J Reichen
Journal:  Ann Intern Med       Date:  1988-08-15       Impact factor: 25.391

7.  Real-time near-infrared (NIR) fluorescent cholangiography in single-site robotic cholecystectomy (SSRC): a single-institutional prospective study.

Authors:  Giuseppe Spinoglio; Fabio Priora; Paolo Pietro Bianchi; Francesco Saverio Lucido; Alessio Licciardello; Valeria Maglione; Federica Grosso; Raul Quarati; Ferruccio Ravazzoni; Luca Matteo Lenti
Journal:  Surg Endosc       Date:  2012-12-28       Impact factor: 4.584

8.  Application of fluorescent cholangiography to single-incision laparoscopic cholecystectomy.

Authors:  Takeaki Ishizawa; Junichi Kaneko; Yosuke Inoue; Nobuyuki Takemura; Yasuji Seyama; Taku Aoki; Yoshifumi Beck; Yasuhiko Sugawara; Kiyoshi Hasegawa; Nobuhiro Harada; Masayoshi Ijichi; Koji Kusaka; Masayuki Shibasaki; Yasutsugu Bandai; Norihiro Kokudo
Journal:  Surg Endosc       Date:  2011-03-18       Impact factor: 4.584

9.  Traditional versus single-site placement of adjustable gastric banding: a comparative study and cost analysis.

Authors:  Subhashini M Ayloo; Nicolas C Buchs; Pietro Addeo; Francesco M Bianco; Pier C Giulianotti
Journal:  Obes Surg       Date:  2011-07       Impact factor: 4.129

10.  Robotic single-incision laparoscopic cholecystectomy.

Authors:  Philippe Morel; Francois Pugin; Pascal Bucher; Nicolas C Buchs; Monika E Hagen
Journal:  J Robot Surg       Date:  2011-10-22
View more
  18 in total

1.  The utilization of fluorescent cholangiography during robotic cholecystectomy at an inner-city academic medical center.

Authors:  Sidharth Sharma; Raymond Huang; Shirley Hui; Michael C Smith; Paul J Chung; Alexander Schwartzman; Gainosuke Sugiyama
Journal:  J Robot Surg       Date:  2017-11-27

2.  Near-infrared fluorescent cholangiography facilitates identification of biliary anatomy during laparoscopic cholecystectomy.

Authors:  Sylvester N Osayi; Mark R Wendling; Joseph M Drosdeck; Umer I Chaudhry; Kyle A Perry; Sabrena F Noria; Dean J Mikami; Bradley J Needleman; Peter Muscarella; Mahmoud Abdel-Rasoul; David B Renton; W Scott Melvin; Jeffrey W Hazey; Vimal K Narula
Journal:  Surg Endosc       Date:  2014-07-02       Impact factor: 4.584

Review 3.  Utility of fluorescent cholangiography during laparoscopic cholecystectomy: A systematic review.

Authors:  Antonio Pesce; Gaetano Piccolo; Gaetano La Greca; Stefano Puleo
Journal:  World J Gastroenterol       Date:  2015-07-07       Impact factor: 5.742

4.  The influence of fluorescence imaging on the location of bowel transection during robotic left-sided colorectal surgery.

Authors:  Minia Hellan; Giuseppe Spinoglio; Alessio Pigazzi; Jorge A Lagares-Garcia
Journal:  Surg Endosc       Date:  2014-01-03       Impact factor: 4.584

Review 5.  Fluorescence-guided hepatobiliary surgery with long and short wavelength fluorophores.

Authors:  Thinzar M Lwin; Robert M Hoffman; Michael Bouvet
Journal:  Hepatobiliary Surg Nutr       Date:  2020-10       Impact factor: 7.293

6.  Optimization of near-infrared fluorescence cholangiography for open and laparoscopic surgery.

Authors:  Floris P R Verbeek; Boudewijn E Schaafsma; Quirijn R J G Tummers; Joost R van der Vorst; Wendeline J van der Made; Coen I M Baeten; Bert A Bonsing; John V Frangioni; Cornelis J H van de Velde; Alexander L Vahrmeijer; Rutger-Jan Swijnenburg
Journal:  Surg Endosc       Date:  2014-04       Impact factor: 4.584

7.  Accuracy of Near Infrared-Guided Surgery in Morbidly Obese Subjects Undergoing Laparoscopic Cholecystectomy.

Authors:  Fernando Dip; David Nguyen; Lisandro Montorfano; María Eugenia Szretter Noste; Emanuele Lo Menzo; Conrad Simpfendorfer; Samuel Szomstein; Raul Rosenthal
Journal:  Obes Surg       Date:  2016-03       Impact factor: 4.129

8.  Robotic single-site combined cholecystectomy and hysterectomy: Advantages and limits.

Authors:  Nicola Pluchino; Nicolas C Buchs; Panagiotis Drakopoulos; Jean Marie Wenger; Philippe Morel; Patrick Dällenbach
Journal:  Int J Surg Case Rep       Date:  2014-10-29

Review 9.  Fluorescent imaging of the biliary tract during laparoscopic cholecystectomy.

Authors:  Darren Leonard Scroggie; Claire Jones
Journal:  Ann Surg Innov Res       Date:  2014-08-12

10.  Clinical applications of indocyanine green (ICG) enhanced fluorescence in laparoscopic surgery.

Authors:  Luigi Boni; Giulia David; Alberto Mangano; Gianlorenzo Dionigi; Stefano Rausei; Sebastiano Spampatti; Elisa Cassinotti; Abe Fingerhut
Journal:  Surg Endosc       Date:  2014-10-11       Impact factor: 4.584

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.