Literature DB >> 24986018

Near-infrared fluorescent cholangiography facilitates identification of biliary anatomy during laparoscopic cholecystectomy.

Sylvester N Osayi1, Mark R Wendling, Joseph M Drosdeck, Umer I Chaudhry, Kyle A Perry, Sabrena F Noria, Dean J Mikami, Bradley J Needleman, Peter Muscarella, Mahmoud Abdel-Rasoul, David B Renton, W Scott Melvin, Jeffrey W Hazey, Vimal K Narula.   

Abstract

BACKGROUND: Intraoperative cholangiography (IOC) is the current gold standard for biliary imaging during laparoscopic cholecystectomy (LC). However, utilization of IOC remains low. Near-infrared fluorescence cholangiography (NIRF-C) is a novel, noninvasive method for real-time, intraoperative biliary mapping. Our aims were to assess the safety and efficacy of NIRF-C for identification of biliary anatomy during LC.
METHODS: Patients were administered indocyanine green (ICG) prior to surgery. NIRF-C was used to identify extrahepatic biliary structures before and after partial and complete dissection of Calot's triangle. Routine IOC was performed in each case. Identification of biliary structures using NIRF-C and IOC, and time required to complete each procedure were collected.
RESULTS: Eighty-two patients underwent elective LC with NIRF-C and IOC. Mean age and body mass index (BMI) were 42.6 ± 13.7 years and 31.5 ± 8.2 kg/m(2), respectively. ICG was administered 73.8 ± 26.4 min prior to incision. NIRF-C was significantly faster than IOC (1.9 ± 1.7 vs. 11.8 ± 5.3 min, p < 0.001). IOC was unobtainable in 20 (24.4 %) patients while NIRF-C did not visualize biliary structures in 4 (4.9 %) patients. After complete dissection, the rates of visualization of the cystic duct, common bile duct, and common hepatic duct using NIRF-C were 95.1, 76.8, and 69.5 %, respectively, compared to 72.0, 75.6, and 74.3 % for IOC. In 20 patients where IOC could not be obtained, NIRF-C successfully identified biliary structures in 80 % of the cases. Higher BMI was not a deterrent to visualization of anatomy with NIRF-C. No adverse events were observed with NIRF-C.
CONCLUSIONS: NIRF-C is a safe and effective alternative to IOC for imaging extrahepatic biliary structures during LC. This technique should be evaluated further under a variety of acute and chronic gallbladder inflammatory conditions to determine its usefulness in biliary ductal identification.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24986018      PMCID: PMC4415528          DOI: 10.1007/s00464-014-3677-5

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  34 in total

1.  An overview of 711 general surgery liability cases. The anatomy of surgical malpractice claims.

Authors:  K A Kern
Journal:  Bull Am Coll Surg       Date:  1995-08

2.  Near-infrared fluorescent type II quantum dots for sentinel lymph node mapping.

Authors:  Sungjee Kim; Yong Taik Lim; Edward G Soltesz; Alec M De Grand; Jaihyoung Lee; Akira Nakayama; J Anthony Parker; Tomislav Mihaljevic; Rita G Laurence; Delphine M Dor; Lawrence H Cohn; Moungi G Bawendi; John V Frangioni
Journal:  Nat Biotechnol       Date:  2003-12-07       Impact factor: 54.908

3.  Costs and utilization of intraoperative cholangiography.

Authors:  Edward H Livingston; Jordan A G Miller; Brian Coan; Robert V Rege
Journal:  J Gastrointest Surg       Date:  2007-06-30       Impact factor: 3.452

4.  Common bile duct injury during laparoscopic cholecystectomy and the use of intraoperative cholangiography: adverse outcome or preventable error?

Authors:  D R Flum; T Koepsell; P Heagerty; M Sinanan; E P Dellinger
Journal:  Arch Surg       Date:  2001-11

5.  Real-time near-infrared (NIR) fluorescent cholangiography in single-site robotic cholecystectomy (SSRC): a single-institutional prospective study.

Authors:  Giuseppe Spinoglio; Fabio Priora; Paolo Pietro Bianchi; Francesco Saverio Lucido; Alessio Licciardello; Valeria Maglione; Federica Grosso; Raul Quarati; Ferruccio Ravazzoni; Luca Matteo Lenti
Journal:  Surg Endosc       Date:  2012-12-28       Impact factor: 4.584

6.  Is routine intraoperative cholangiogram necessary in the twenty-first century? A national view.

Authors:  Elizaveta Ragulin-Coyne; Elan R Witkowski; Zeling Chau; Sing Chau Ng; Heena P Santry; Mark P Callery; Shimul A Shah; Jennifer F Tseng
Journal:  J Gastrointest Surg       Date:  2013-01-05       Impact factor: 3.452

7.  Bile duct injury during laparoscopic cholecystectomy: results of a national survey.

Authors:  S B Archer; D W Brown; C D Smith; G D Branum; J G Hunter
Journal:  Ann Surg       Date:  2001-10       Impact factor: 12.969

8.  Bile duct injury during laparoscopic cholecystectomy: results of an Italian national survey on 56 591 cholecystectomies.

Authors:  Gennaro Nuzzo; Felice Giuliante; Ivo Giovannini; Francesco Ardito; Fabrizio D'Acapito; Maria Vellone; Marino Murazio; Giovanni Capelli
Journal:  Arch Surg       Date:  2005-10

9.  Fluorescence cholangiography during laparoscopic cholecystectomy: a feasibility study on early biliary tract delineation.

Authors:  Rutger M Schols; Nicole D Bouvy; Ad A M Masclee; Ronald M van Dam; Cornelis H C Dejong; Laurents P S Stassen
Journal:  Surg Endosc       Date:  2012-10-18       Impact factor: 4.584

10.  Real-time near-infrared fluorescent cholangiography could shorten operative time during robotic single-site cholecystectomy.

Authors:  Nicolas C Buchs; François Pugin; Dan E Azagury; Minoa Jung; Francesco Volonte; Monika E Hagen; Philippe Morel
Journal:  Surg Endosc       Date:  2013-05-14       Impact factor: 4.584

View more
  39 in total

1.  Minimalist approach to donor hepatectomy.

Authors:  See Ching Chan; Sheung Tat Fan
Journal:  Hepatol Int       Date:  2015-10-08       Impact factor: 6.047

Review 2.  Utility of fluorescent cholangiography during laparoscopic cholecystectomy: A systematic review.

Authors:  Antonio Pesce; Gaetano Piccolo; Gaetano La Greca; Stefano Puleo
Journal:  World J Gastroenterol       Date:  2015-07-07       Impact factor: 5.742

3.  SAGES clinical spotlight review: intraoperative cholangiography.

Authors:  William W Hope; Robert Fanelli; Danielle S Walsh; Vimal K Narula; Ray Price; Dimitrios Stefanidis; William S Richardson
Journal:  Surg Endosc       Date:  2017-03-31       Impact factor: 4.584

4.  SAGES Technology and Value Assessment Committee safety and effectiveness analysis on immunofluorescence in the operating room for biliary visualization and perfusion assessment.

Authors:  Bryan J Sandler; Danny Sherwinter; Lucian Panait; Richard Parent; Jennifer Schwartz; David Renton
Journal:  Surg Endosc       Date:  2017-06-22       Impact factor: 4.584

5.  Clinical value and pitfalls of fluorescent cholangiography during single-incision laparoscopic cholecystectomy.

Authors:  Tsuyoshi Igami; Motoi Nojiri; Kentaro Shinohara; Tomoki Ebata; Yukihiro Yokoyama; Gen Sugawara; Takashi Mizuno; Junpei Yamaguchi; Masato Nagino
Journal:  Surg Today       Date:  2016-03-22       Impact factor: 2.549

6.  Measuring intra-operative decision-making during laparoscopic cholecystectomy: validity evidence for a novel interactive Web-based assessment tool.

Authors:  Amin Madani; Yusuke Watanabe; Elif Bilgic; Philip H Pucher; Melina C Vassiliou; Rajesh Aggarwal; Gerald M Fried; Elliot J Mitmaker; Liane S Feldman
Journal:  Surg Endosc       Date:  2016-07-13       Impact factor: 4.584

Review 7.  Beyond the margins: real-time detection of cancer using targeted fluorophores.

Authors:  Ray R Zhang; Alexandra B Schroeder; Joseph J Grudzinski; Eben L Rosenthal; Jason M Warram; Anatoly N Pinchuk; Kevin W Eliceiri; John S Kuo; Jamey P Weichert
Journal:  Nat Rev Clin Oncol       Date:  2017-01-17       Impact factor: 66.675

Review 8.  The emerging role for robotics in cholecystectomy: the dawn of a new era?

Authors:  Jessica A Zaman; Tejender Paul Singh
Journal:  Hepatobiliary Surg Nutr       Date:  2018-02       Impact factor: 7.293

9.  Accuracy of Near Infrared-Guided Surgery in Morbidly Obese Subjects Undergoing Laparoscopic Cholecystectomy.

Authors:  Fernando Dip; David Nguyen; Lisandro Montorfano; María Eugenia Szretter Noste; Emanuele Lo Menzo; Conrad Simpfendorfer; Samuel Szomstein; Raul Rosenthal
Journal:  Obes Surg       Date:  2016-03       Impact factor: 4.129

Review 10.  Clinical application of indocyanine green-fluorescence imaging during hepatectomy.

Authors:  Takeaki Ishizawa; Akio Saiura; Norihiro Kokudo
Journal:  Hepatobiliary Surg Nutr       Date:  2016-08       Impact factor: 7.293

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.