Literature DB >> 2365554

Electroretinographic responses of the short-wavelength-sensitive cones.

P Gouras1, C J MacKay.   

Abstract

An electroretinographic response of the human short wavelength (S) cone system can be distinguished from that of the longer wavelength (L or M) cone system by using ganzfeld short-wavelength stimulation at relatively high levels of retinal adaptation. The S cone response has both an a- and b-wave component in its ERG, both of which are slower than those of the L or M cone response at the same level of retinal adaptation. Proof that this is the S cone response is obtained by action spectra and by examination of a sex-linked achromat who is known to have only S cone and rod vision. This approach allows the simultaneous and rapid assessment of both the S and the L or M cone systems in the human retina using conventional electroretinogram (ERG) equipment, ganzfeld blue flashes on a white background, and computer averaging.

Entities:  

Mesh:

Year:  1990        PMID: 2365554

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  22 in total

Review 1.  [Achromatopsia].

Authors:  C M Poloschek; S Kohl
Journal:  Ophthalmologe       Date:  2010-06       Impact factor: 1.059

2.  S-cone electroretinogram to Ganzfeld stimuli in patients with retinitis pigmentosa.

Authors:  S Yamamoto; M Hayashi; S Takeuchi
Journal:  Doc Ophthalmol       Date:  1999       Impact factor: 2.379

3.  Electroretinography of short-wavelength-sensitive cones with a LED built-in electrode and its normal values.

Authors:  Kazuki Kuniyoshi; Naoki Uno; Motohiro Irifune; Yoshikazu Shimomura
Journal:  Doc Ophthalmol       Date:  2003-05       Impact factor: 2.379

4.  Spectral characteristics of light sources for S-cone stimulation.

Authors:  F Schlegelmilch; R Nolte; K Schellhorn; P Husar; G Henning; R P Tornow
Journal:  Doc Ophthalmol       Date:  2002-11       Impact factor: 2.379

5.  Built-in LED contact lens electrode for S-cone electroretinographic recordings.

Authors:  Mieko Tsuruoka; Shuichi Yamamoto; Kazuha Ogata; Masanori Hayashi
Journal:  Doc Ophthalmol       Date:  2004-01       Impact factor: 2.379

6.  Electroretinographic evaluation of the retinal S-cone system.

Authors:  Maja Sustar; Marko Hawlina; Jelka Brecelj
Journal:  Doc Ophthalmol       Date:  2011-11-27       Impact factor: 2.379

7.  Large-field S-cone flicker test.

Authors:  W M Budde; M Korth; C Y Mardin
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1997-07       Impact factor: 3.117

8.  Blue cone monochromatism: clinical findings in patients with mutations in the red/green opsin gene cluster.

Authors:  Ulrich Kellner; Bernd Wissinger; Sabine Tippmann; Susanne Kohl; Hannelore Kraus; Michael H Foerster
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2004-09       Impact factor: 3.117

9.  The photopic negative response of the blue-on-yellow flash-electroretinogram in glaucomas and normal subjects.

Authors:  Nina Wakili; Folkert K Horn; Anselm G Jünemann; Nhung X Nguyen; Christian Y Mardin; Matthias Korth; Jan Kremers
Journal:  Doc Ophthalmol       Date:  2008-02-14       Impact factor: 2.379

10.  Blue cone monochromacy: causative mutations and associated phenotypes.

Authors:  Jessica C Gardner; Michel Michaelides; Graham E Holder; Naheed Kanuga; Tom R Webb; John D Mollon; Anthony T Moore; Alison J Hardcastle
Journal:  Mol Vis       Date:  2009-05-01       Impact factor: 2.367

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.