Literature DB >> 23652813

Water infusion versus air insufflation for colonoscopy: a meta-analysis of randomized controlled trials.

D Hu1, Y Xu, Y Sun, Q Zhu.   

Abstract

BACKGROUND: The aim of this meta-analysis was to determine whether water infusion colonoscopy (WIC) is a more effective diagnostic tool than standard air insufflation colonoscopy (AIC).
METHODS: All articles pertinent to a comparison of water-related methods and air insufflation to facilitate insertion of the colonoscope were retrieved from PubMed, Web of Science, Embase, and Cochrane databases. Pooling results were derived by using the Review Manager Software. Outcomes were assessed using the weighted mean difference (MD) with 95 % confidence intervals (CI) for continuous variables and the odds ratios (OR) with 95 % CI for dichotomous variables.
RESULTS: Eighteen studies involving 2,797 patients were included. WIC was associated with a significantly higher cecal intubation rate than AIC (OR = 1.90; 95 % CI 1.21-2.99; p = 0.005). The intubation time was similar for the two types of colonoscopy, but in WIC there was a significantly lower visual analog scale score for abdominal pain than in AIC (MD = -1.30; 95 % CI -2.03 to -0.58; p < 0.001) without sacrificing the polyp detection rate (OR = 1.17; 95 % CI 0.78-1.77; p = 0.44). Statistically, the patient's willingness to repeat colonoscopy was significantly greater for WIC than for AIC (OR = 1.74; 95 % CI 1.14-2.67; p < 0.01). Furthermore, in the subgroup for trainees, the WIC group achieved a higher cecal intubation rate (OR = 1.83; 95 % CI 1.15-2.93; p = 0.01) and a shorter intubation time (MD = -1.72 min; 95 % CI -3.34 to -0.11; p = 0.04) than the AIC group.
CONCLUSIONS: In contrast to AIC, WIC improved cecal intubation, alleviated abdominal pain, and increased patients' willingness to repeat the procedure.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23652813     DOI: 10.1007/s10151-013-1023-x

Source DB:  PubMed          Journal:  Tech Coloproctol        ISSN: 1123-6337            Impact factor:   3.781


  29 in total

1.  Quantifying heterogeneity in a meta-analysis.

Authors:  Julian P T Higgins; Simon G Thompson
Journal:  Stat Med       Date:  2002-06-15       Impact factor: 2.373

2.  Warm water or oil-assisted colonoscopy: toward simpler examinations?

Authors:  Emilio Brocchi; Raffaele Pezzilli; Paola Tomassetti; Davide Campana; Antonio M Morselli-Labate; Roberto Corinaldesi
Journal:  Am J Gastroenterol       Date:  2007-12-12       Impact factor: 10.864

3.  Limited water infusion decreases pain during minimally sedated colonoscopy.

Authors:  Yu-Hsi Hsieh; Hwai-Jeng Lin; Kuo-Chih Tseng
Journal:  World J Gastroenterol       Date:  2011-05-07       Impact factor: 5.742

4.  Water immersion versus standard colonoscopy insertion technique: randomized trial shows promise for minimal sedation.

Authors:  C W Leung; T Kaltenbach; R Soetikno; K K Wu; F W Leung; S Friedland
Journal:  Endoscopy       Date:  2010-06-30       Impact factor: 10.093

5.  Should colonoscopy be the first investigation for colonic disease?

Authors:  D C Lindsay; J G Freeman; I Cobden; C O Record
Journal:  Br Med J (Clin Res Ed)       Date:  1988-01-16

6.  Operating characteristics of a rank correlation test for publication bias.

Authors:  C B Begg; M Mazumdar
Journal:  Biometrics       Date:  1994-12       Impact factor: 2.571

7.  Patient tolerance of colonoscopy without sedation during screening examination for colorectal polyps.

Authors:  E Thiis-Evensen; G S Hoff; J Sauar; M H Vatn
Journal:  Gastrointest Endosc       Date:  2000-11       Impact factor: 9.427

8.  Pilot feasibility study of the method of water infusion without air insufflation in sedated colonoscopy.

Authors:  Joseph W Leung; Rodolei Salera; Lee Toomsen; Surinder Mann; Felix W Leung
Journal:  Dig Dis Sci       Date:  2008-12-05       Impact factor: 3.199

Review 9.  Water-related techniques for performance of colonoscopy.

Authors:  Felix W Leung
Journal:  Dig Dis Sci       Date:  2008-05-07       Impact factor: 3.199

10.  A randomized, controlled comparison of warm water infusion in lieu of air insufflation versus air insufflation for aiding colonoscopy insertion in sedated patients undergoing colorectal cancer screening and surveillance.

Authors:  Joseph W Leung; Surinder K Mann; Rodelei Siao-Salera; Kanat Ransibrahmanakul; Brian Lim; Hazel Cabrera; Wilhemina Canete; Paul Barredo; Rebeck Gutierrez; Felix W Leung
Journal:  Gastrointest Endosc       Date:  2009-06-24       Impact factor: 9.427

View more
  4 in total

Review 1.  Diagnostic and therapeutic applications of water-immersion colonoscopy.

Authors:  Shinya Sugimoto; Takeshi Mizukami
Journal:  World J Gastroenterol       Date:  2015-06-07       Impact factor: 5.742

2.  When and why a colonoscopist should discontinue colonoscopy by himself?

Authors:  Tao Gan; Jin-Lin Yang; Jun-Chao Wu; Yi-Ping Wang; Li Yang
Journal:  World J Gastroenterol       Date:  2015-07-07       Impact factor: 5.742

3.  The Secondary Quality Indicator to Improve Prediction of Adenoma Miss Rate Apart from Adenoma Detection Rate.

Authors:  Satimai Aniwan; Piyachai Orkoonsawat; Vichai Viriyautsahakul; Phonthep Angsuwatcharakon; Rapat Pittayanon; Naruemon Wisedopas; Sakolkun Sumdin; Yuwadee Ponuthai; Sumitra Wiangngoen; Pinit Kullavanijaya; Rungsun Rerknimitr
Journal:  Am J Gastroenterol       Date:  2016-01-26       Impact factor: 10.864

Review 4.  Is water exchange superior to water immersion for colonoscopy? A systematic review and meta-analysis.

Authors:  Zhihao Chen; Zhengqi Li; Xinying Yu; Guiqi Wang
Journal:  Saudi J Gastroenterol       Date:  2018 Sep-Oct       Impact factor: 2.485

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.